Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K021752

    Validate with FDA (Live)

    Date Cleared
    2002-10-11

    (136 days)

    Product Code
    Regulation Number
    886.5916
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    FP(hexafocon A) and ASP(hexafocon A) RGP Contact Lens are indicated for daily wear for the correction of refractive amptropia (myopia, lyperopia, astigmatism) in aphakic and not- aphakic persons with nondiseased eyes. The lens may be disinfected using a chemical disinfecting system only.

    Device Description

    FP(hexafocon A) RGP Contact Lens Spherical and ASP(hexafocon A) RGP Contact Lens Aspherical are indicated for daily wear for the correction of refractive ametropia (myopia, hyperopia and astigmatism) in aphakic and not aphakic persons with nondiseased eyes. The lens may be disinfected using a chemical(not heat) disinfecting system only.

    The FP(hexafocon A) RGP Contact Lens Spherical and ASP(hexafocon A) RGP Contact Lens Aspherical are is hemispherical shell of the following dimentions.

    · Diameter: 8.00 to 10.00mm
    · Center Thickness: 0.10 to 0.50mm
    · Base Curve: 6.00 to 9.00mm
    · Power: -20.0 to +20.0 diopter

    The physical properties of the lens are

    • · Specific Gravity 1.27
    • · Refractive Index 1.415
    • · Light Transmittance 92%
    • · Surface Character Hydrophobic
    • 490 · Wetting Angle
    • · Water Content <1%
    • · Hardness(shore D) 81
    • 140*(100**) { × 10 + ( cm3 O2 cm ) ( cm2 sec mm Hg ) @ 3 5 ℃ } · Oxygen Permeability
      • gas to gas method
    • ** polarographic method(ISO/Fatt)
    AI/ML Overview

    The provided text does not contain information about specific acceptance criteria, device performance studies, sample sizes, expert qualifications, or ground truth establishment relevant to the request.

    This document is a 510(k) Summary of Safety and Effectiveness for a rigid gas permeable contact lens, indicating that the device is substantially equivalent to previously cleared devices. It primarily focuses on the device's technical specifications, intended use, and its equivalence to predicate devices based on material properties and function.

    Therefore, I cannot fulfill the request for information on acceptance criteria, study details, sample sizes, expert involvement, or ground truth methods as this information is not present in the provided text.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1