Found 1 results

510(k) Data Aggregation

    K Number
    K013328

    Validate with FDA (Live)

    Date Cleared
    2001-12-03

    (59 days)

    Product Code
    Regulation Number
    890.5110
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • Useful for symptomatic relief of pain caused by arthritis, bursitis, and chronic joint inflammation.
    • Relaxes muscles, relieves stiffness and muscle spasm.
    • Stimulates circulation and for other conditions where heat is indicated.
    Device Description

    The product covered by this 510(k) summary is a heated paraffin wax spa intended for home use. This product consists of a plastic enclosure, aluminum bucket and an internal heating assembly. The paraffin wax temperature is controlled by a variable electronic heat control with timing circuit. Temperature settings (low, medium, and high) and timing controls are displayed on a liquid crystal display. The product consumes 200 watts when plugged into a standard household electrical outlet supply of 120 Vac, 60 Hertz. The product comes in two different sizes.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the Remington Paraffin Spa, a heated paraffin wax spa. This document primarily focuses on demonstrating substantial equivalence to a predicate device rather than presenting a detailed study with acceptance criteria and performance metrics.

    Therefore, many of the requested details, such as specific acceptance criteria, sample sizes for test and training sets, number and qualifications of experts, adjudication methods, multi-reader multi-case studies, and standalone performance, are not available in the provided text. These types of studies are typically associated with performance evaluations of diagnostic devices or algorithms rather than a relatively simple therapeutic device like a paraffin bath seeking 510(k) clearance based on substantial equivalence.

    Here's what can be extracted from the provided information:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state acceptance criteria or report a device's performance against such criteria. The basis for clearance is "substantial equivalence" to a predicate device.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    Not applicable. No test set or data provenance is mentioned as this is a 510(k) submission based on substantial equivalence, not a clinical trial or performance study.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. No ground truth establishment is described for a test set.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. No adjudication method is described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is not an AI or diagnostic device; therefore, an MRMC study is not relevant to this submission.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is not an algorithm or AI-driven device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Not applicable. The clearance is based on substantial equivalence to a predicate device and similar "principles of operation and technological characteristics."

    8. The sample size for the training set

    Not applicable. There is no mention of a training set as this is not a machine learning or AI device.

    9. How the ground truth for the training set was established

    Not applicable.


    Summary of Information Available from the Provided Text:

    • Device Name: Remington® Paraffin Spa (Models HS-250 and PFS-600)
    • Common Name: Paraffin Bath
    • Intended Use:
      • Symptomatic relief of pain caused by arthritis, bursitis, and chronic joint inflammation.
      • Relaxes muscles, relieves stiffness and muscle spasm.
      • Stimulates circulation and for other conditions where heat is indicated.
    • Classification: Class II, regulated under 21 C.F.R. § 890.5110 (Paraffin Bath).
    • Predicate Device: ParaSpa™ Paraffin Bath by Homedics, Inc. (K001860).
    • Substantial Equivalence Claim Reason: The Remington Paraffin Spa and the HoMedics ParaSpa™ Paraffin Bath have the same intended use and very similar principles of operation and technological characteristics. Minor technological differences do not raise new questions of safety or effectiveness.

    The 510(k) clearance process, especially for devices like a paraffin bath, primarily relies on demonstrating that the new device is as safe and effective as a legally marketed predicate device, rather than proving performance against specific acceptance criteria through extensive clinical studies involving test sets and expert ground truth establishment.