Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K063636

    Validate with FDA (Live)

    Device Name
    ZILOS-TK
    Date Cleared
    2007-04-24

    (138 days)

    Product Code
    Regulation Number
    884.6200
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This system is intended to be used to drill a small tangential hole in or to thin the zona pellucida of the embryo in selected in vitro fertilization (IVF) patients with otherwise poor prognosis for successful pregnancy outcome, such as advanced maternal age, prior failed IVF procedures, cryopreserved embryos, or abnormal zona pellucida morphology, and in IVF patients undergoing PGD to avoid genetic disease or aneuploidy.

    Device Description

    The ZILOS-tk uses an infra-red [IR] laser beam [of wavelength in the range 1450 < 1 < 1480 nm] to locally heat a small spot on the embryo zona pellucida. The IR beam is projected through the microscope objective in a direction opposite to the image light, so that it focuses on the embryo. This epi-irradiating IR beam is confocal with the visible beam, and the user adjusts the line-up of the target to treat the exact region of the zona desired. The beam power is typically 300 mW and the beam is pulsed on for typically 500 usec or less, with a 40x objective. The thermal effect of the beam is to liquefy the zona pellucida in a small region surrounding the focal point, and thereby provide access to the embryo itself. The hole drilled in this manner can be used either to aid hatching or for biopsy cell extraction. The assembled ZILOS-tk laser system is the same length as a microscope objective and can be fitted on to the turret of any inverted microscope. It can be controlled by a desktop or laptop computer.

    AI/ML Overview

    Here's an analysis of the provided text regarding the ZILOS-tk device's acceptance criteria and studies:

    Acceptance Criteria and Device Performance

    The submission for the ZILOS-tk device is primarily focused on extending its Indications for Use to include Laser-Assisted Blastomere or Trophectoderm Biopsy (LAB), in addition to its existing approval for Laser Assisted Hatching (LAH). The core argument for meeting acceptance criteria is that the device itself, its operation, and its effects on the zona pellucida are identical across both applications. Therefore, the safety and effectiveness demonstrated for LAH are directly transferable to LAB.

    Acceptance Criteria (Implicit)Reported Device Performance (for LAB)
    Safety: No increase in embryo damage compared to predicate/LAH use.3-day embryos: More than six hundred 3-day embryos treated with lasers for biopsy assistance, with "no reports of embryo damage."
    5-day embryos (Trophectoderm biopsy): More than 1000 embryos treated, "all of which survived the procedure."
    Effectiveness: Device performs as well as predicate/LAH for drilling the zona pellucida.Device performs "exactly as well as the predicate device" in drilling application. The range of hole diameters used for LAH is "closely similar to that used for LAB."
    Technological Equivalence: Device remains identical to the predicate device."The ZILOS-tk in this Submission is identical to the ZILOS-tk already approved for marketing in its physical properties and in its computer control software." All components (laser, objective, computer, software, microscope type, laser controller, pulse power, pulse duration, firing switch) are identical.

    Study Information

    1. Sample size used for the test set and the data provenance:

      • 3-day embryos (blastomere biopsy): More than six hundred embryos.
      • 5-day embryos (trophectoderm biopsy): More than 1000 embryos.
      • Data Provenance: "numerous laboratories throughout the world." The data appears to be retrospective as it's referred to as "evidence from the field use" and "ZILOS-tk has been applied to laser biopsy and PGD in numerous laboratories throughout the world." Specific countries are not listed, but "France" and "Singapore" are mentioned for other contexts.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • This information is not provided in the document. The "ground truth" here is implied by the reported outcomes (no embryo damage, survival of procedures, successful PGD). However, there's no mention of a formal expert panel establishing a gold standard for these outcomes in the context of the study.
    3. Adjudication method for the test set:

      • None explicitly mentioned. The document states "no reports of embryo damage have been found" and "all of which survived the procedure," suggesting aggregated reporting of outcomes rather than an adjudication process by multiple experts for each case.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No, an MRMC study was not done. This device is a laser system for physical intervention on embryos, not an AI-based diagnostic or imaging device for "human readers." Therefore, this type of study is not applicable.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • No, a standalone (algorithm only) study was not done. The ZILOS-tk is a physical device operated by a human. Its performance is always human-in-the-loop. The "performance data" provided refers to the outcomes of embryos after being treated with the device, which is an integrated human-device process.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • The ground truth relied on is outcomes data (survival of embryos, absence of reported damage) and clinical success (successful PGD to prevent hereditary disease). This is implicitly validated by the medical community's continued use of the device and the successful delivery of healthy infants when PGD is employed.
    7. The sample size for the training set:

      • Not applicable/Not specified. This device is a physical instrument, not an AI model that requires a "training set" in the conventional sense. The "training" here refers to the development and refinement of the device based on engineering principles and prior clinical experience with its predicate function (LAH).
    8. How the ground truth for the training set was established:

      • Not applicable/Not specified. As it's not an AI model, the concept of a "ground truth for a training set" does not directly apply. The device's efficacy and safety for its initial indication (LAH) would have been established through prior clinical use, pre-market approvals (K040045), and scientific understanding of laser-zona interaction. This historical performance serves as the basis for arguing equivalence for the new indication.
    Ask a Question

    Ask a specific question about this device

    K Number
    K050768

    Validate with FDA (Live)

    Date Cleared
    2005-04-28

    (34 days)

    Product Code
    Regulation Number
    884.6200
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Hamilton Thorne ZILOS-tk is to be used to drill a small tangential hole in or to thin the zona pellucida of the embryo in selected in vitro fertilization (IVF) patients with otherwise poor prognosis for successful pregnancy outcome, such as: Advanced maternal age Prior failed IVF Cryopreserved embryos Abnormal zona pellucida morphology

    Device Description

    The Hamilton Thorne Zona Infrared Laser Optical System [ZILOS-tkTM] 1480 nm Diode Laser for Laser Assisted Hatching [LAH].

    AI/ML Overview

    This appears to be a 510(k) clearance letter from the FDA for a medical device called the "Zona Infrared Laser Optical System [ZILOS-tk™] 1480nm Diode Laser for Laser Assisted Hatching [LAH]".

    The document does not contain the detailed information necessary to answer your request about acceptance criteria and the study proving the device meets them. This type of information is typically found in the 510(k) summary submitted by the manufacturer, not in the clearance letter itself.

    The clearance letter primarily states that the FDA has reviewed the premarket notification and determined the device is substantially equivalent to legally marketed predicate devices, allowing it to be marketed. It refers to "indications for use" but does not detail performance criteria or study results that would demonstrate how those indications are met.

    Therefore, I cannot provide the requested table and study details based on the provided text.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1