Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K200955

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-07-08

    (90 days)

    Product Code
    Regulation Number
    870.3470
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Vascutek Cardiovascular Fabric is indicated for vascular repair whenever knitted polyester fabrics are normally indicated.

    Due to its particularly high strength. Gelseal is especially suitable for thoracic use whereas the softer handle of the Gelsoft makes it ideal for peripheral use. The Thin Wall fabric is designed for endaterectorny, particularly of the carotid arteries.

    Device Description

    The Vascutek Cardiovascular Fabric are a range of gelatin sealed, knitted, polyester patch fabrics. The range consists of three different patch fabrics which are manufactured using identical materials, processes and procedures but which, because of slight differences in the pattern of the base fabric, exhibit different physical characteristics. This range of products is provided in order to give the implanting surgeon a choice of several different fabrics from which they can chose the most suitable according to their own preferences and according to specific demands of any given surgical situation.

    Two of the patches, Gelseal™ and Gelsoft™, are based on fabrics which are currently used in Vascutek's range of tubular vascular prostheses, which have received Premarket approval from the FDA. The only difference between the cardiovascular fabrics and the tubular grafts is that the patches are produced in flat, patch formats (i.e. square or rectangular) and have not been subjected to the crimping process which is used in the production of the tubular prostheses. With this single exception, the manufacturing facilities, equipment, processes and the quality control processes and procedures are identical to those used in the manufacture of the Gelseal™ and Gelsoft™ vascular prostheses.

    The third type of patch, the Thin Wall Carotid Patch, is also manufactured using the identical materials, processes and procedures as the other cardiovascular patches but with a slightly modified knit pattern. This new structure has been developed in order to maintain the physical characteristics necessary for general cardiovascular patching but with a reduced wall thickness and characteristics which make it ideally suited to use for parching carotid arteries after endarterectomy procedures.

    AI/ML Overview

    This is a 510(k) premarket notification for a medical device, not a study evaluating an AI algorithm. Therefore, the requested information about acceptance criteria, study design, expert involvement, and ground truth for an AI device is not available in the provided text.

    The document describes the Vascutek Gelseal Patch, Vascutek Gelsoft Patch, and Vascutek Thin Wall Carotid Patch, which are cardiovascular fabric patches. The FDA has determined these devices are substantially equivalent to legally marketed predicate devices.

    The "study" referenced in the document is a series of nonclinical tests performed to demonstrate that the device is safe and effective when compared to predicate devices. These tests included:

    • Physical testing
    • Biocompatibility testing
    • Chemical characterization
    • An animal performance study

    The purpose of these tests was to show that the new devices, with a change in the gelatin supplier, perform as well as the previously approved devices.

    Since this is not an AI device, the specific questions about acceptance criteria related to AI performance metrics (like sensitivity, specificity, or AUC), sample sizes for AI training/test sets, expert adjudication, or MRMC comparative effectiveness studies are not applicable and therefore cannot be answered from the provided text.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1