510(k) Data Aggregation

    K Number
    K953644

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1996-03-08

    (217 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Reference & Predicate Devices
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Synthes Volar Distal Radius Plate is intended for fixation of fractures and osteotomies of the distal radius, applied to the volar aspect.

    Device Description

    Synthes Volar Distal Radius Plate is intended for fixation of fractures and osteotomies of the distal radius, applied to the volar aspect. It is manufactured from commercially pure titanium. The plate is T-shaped, with the head 10° from perpendicular to the shaft, is precontoured, and is available in right and left versions. The head can be cut to size; it has up to six threaded holes, and accepts either 2.4 mm Cortex Screws or 1.8 mm Buttress Pins. The shaft can also be cut to size, and has up to five compression holes, two being elongated shaft holes to facilitate positioning, and accepts 2.7 mm Cortex Screws.

    AI/ML Overview

    This document describes a medical device, the Synthes Volar Distal Radius Plate, and compares it to an existing device, the Synthes Small T-Plate. However, it does not contain information about acceptance criteria or a study related to device performance in terms of diagnostic accuracy or clinical effectiveness for AI/ML or imaging-based devices.

    The document focuses on:

    • Intended Use: Fixation of fractures and osteotomies of the distal radius.
    • Material: Commercially pure titanium for the new device, 316L stainless steel for the comparator.
    • Design Features: T-shaped, precontoured, dimensions, screw types accepted.
    • Sterilization: Gamma radiation for sterile versions, steam sterilization guidelines for non-sterile.
    • Performance Claim: Based on mechanical testing, the Synthes Volar Distal Radius Plate is at least equivalent to the Synthes Small T-Plate.

    Therefore, I cannot fulfill your request for the following information as it is not present in the provided text:

    1. A table of acceptance criteria and the reported device performance (in terms of diagnostic accuracy/clinical outcomes).
    2. Sample size used for the test set and the data provenance.
    3. Number of experts used to establish the ground truth for the test set and their qualifications.
    4. Adjudication method for the test set.
    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done.
    6. If a standalone (algorithm only) performance study was done.
    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.).
    8. The sample size for the training set.
    9. How the ground truth for the training set was established.

    This document describes a traditional medical implant, and the "study" mentioned is "mechanical testing" to demonstrate equivalence in physical properties, not clinical or diagnostic performance.