Found 3 results

510(k) Data Aggregation

    K Number
    K210164

    Validate with FDA (Live)

    Date Cleared
    2021-03-10

    (48 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Vantage Elan systems are indicated for use as a diagnostic imaging modality that produces crosssectional transaxial, coronal, sagittal, and oblique images that display anatomic structures of the head or body. Additionally, this system is capable of non-contrast enhanced imaging, such as MRA.

    MRI (magnetic resonance imaging) images correspond to the spatial distribution of protons (hydrogen nuclei) that exhibit nuclear magnetic resonance (NMR). The NMR properties of body tissues and fluids are:

    • Proton density (PD) (also called hydrogen density)
    • Spin-lattice relaxation time (T1)
    • Spin-spin relaxation time (T2) ●
    • . Flow dynamics
    • Chemical Shift

    Depending on the region of interest, contrast agents may be used. When interpreted by a trained physician, these images yield information that can be useful in diagnosis.

    Device Description

    The Vantage Elan (Model MRT-2020) is a 1.5 Tesla Magnetic Resonance Imaging (MRI) System, previously cleared under K171597. This system is based upon the technology and materials of previously marketed Canon Medical Systems and is intended to acquire and display crosssectional transaxial, coronal, sagittal, and oblique images of anatomic structures of the head or body. The Vantage Elan uses 1.4m short and 4.1 ton light weight magnet. It includes the Pianissimo™ Σ technology (scan noise reduction technology). The design of the gradient coil and the whole body coil of the Vantage Elan provides the maximum field of view of 55 x 50 cm. The Model MRT-2020/A1 is without secondary cooling system and the Model MRT-2020/A2 is with secondary cooling system.

    AI/ML Overview

    The document describes the acceptance criteria and supporting studies for the Vantage Elan 1.5T, MRT-2020, V6.0 MRI System, specifically regarding new software functionalities and sequence enhancements.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not provide a specific table of quantitative acceptance criteria with corresponding performance metrics for each new feature. Instead, it describes general conclusions after evaluation.

    Here's a summary derived from the text:

    Feature EvaluatedAcceptance Criteria (Implied)Reported Device Performance
    T2 Map Using Pre-Contrast PulsesT2 maps can be accurately generated from acquired data."It was concluded that T2 maps can be generated using the data acquired using pre-contrast pulses."
    WFS DIXON (Water Fat Separation)Water and fat signals are effectively separated."Testing verified that water signals and fat signals are separated in the water image and the fat image, respectively."
    2D-RMC (Real Time Motion Correction) for EPIEffective mitigation of motion artifacts during scanning."Testing verified the use of 2DRMC in scanning with SEEPI2D sequence is effective."
    SpineLine+, KneeLine+, surevol Knee, Quick Star, Fast 3D modeFeatures work as intended, and images are of diagnostic quality; test results meet predetermined acceptance criteria."It was confirmed that these features worked as intended, the images were of diagnostic quality, and the test results met predetermined acceptance criteria."

    2. Sample Size Used for the Test Set and Data Provenance

    The document mentions the use of "phantom and volunteer images" for the evaluation of T2 Map, WFS DIXON, and 2D-RMC. For SpineLine+, KneeLine+, surevol Knee, Quick Star, and Fast 3D mode, "volunteer images" were utilized.

    • Sample Size (Test Set): Not explicitly stated with specific numbers of phantoms or volunteers.
    • Data Provenance: Not specified (e.g., country of origin). The studies appear to be prospective as they were conducted for the purpose of verifying the new functionalities.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    This information is not provided in the document. The evaluations are described as "testing verified" or "it was concluded/confirmed," but there is no mention of expert involvement in establishing ground truth for the test images.

    4. Adjudication Method for the Test Set

    The document does not specify any adjudication method for the test set.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    There is no mention of an MRMC comparative effectiveness study being performed, nor any effect size information regarding human reader improvement with or without AI assistance. The document focuses on the technical performance and diagnostic quality of the new features.

    6. Standalone (Algorithm Only) Performance

    The document describes the evaluation of software functionalities and sequence enhancements, implying standalone performance evaluation for these features. For instance, "testing verified that water signals and fat signals are separated" for WFS DIXON and "it was concluded that T2 maps can be generated" for T2 Map using pre-contrast pulses. These statements refer to the direct output and functionality of the algorithms/sequences.

    7. Type of Ground Truth Used

    Based on the descriptions:

    • For WFS DIXON and T2 Map: The ground truth appears to be based on the expected physical and technical outcomes (e.g., successful separation of water/fat, generation of T2 maps). This would likely involve expert evaluation of the image output against expected results, potentially using quantitative metrics.
    • For 2D-RMC and other imaging features (SpineLine+, KneeLine+, etc.): The ground truth is implied to be visual assessment of diagnostic image quality and confirmation that the features "worked as intended." This would likely involve expert radiologists/technicians evaluating the images to ensure they are free of artifacts, properly positioned, and diagnostically usable. It's an expert consensus or clinical utility assessment of the generated images, rather than a comparison to a definitive pathology report or outcome data.

    8. Sample Size for the Training Set

    The document does not provide any information regarding the sample size for a training set. Given that these are software functionalities for an MRI system, rather than an AI-driven diagnostic algorithm, direct "training data" in the typical machine learning sense might not be explicitly used or reported in this context. The functions like SpineLine+ or KneeLine+ could use pre-programmed anatomical models or algorithms rather than statistical learning from a large, labeled dataset in the way a CAD system would.

    9. How the Ground Truth for the Training Set Was Established

    As no training set is mentioned (see point 8), there is no information on how its ground truth would have been established.

    Ask a Question

    Ask a specific question about this device

    K Number
    K171597

    Validate with FDA (Live)

    Date Cleared
    2017-07-21

    (51 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Vantage Elan systems are indicated for use as a diagnostic imaging modality that produces cross-sectional transaxial. coronal, sagittal, and obligue images that display anatomic structures of the head or body. Additionally, this system is capable of non-contrast enhanced imaging, such as MRA.

    MRI (magnetic resonance imaging) images correspond to the spatial distribution of protons (hydrogen nuclei) that exhibit nuclear magnetic resonance (NMR). The NMR properties of body tissues and fluids are:

    • · Proton density (PD) (also called hydrogen density)
    • · Spin-lattice relaxation time (T1)
    • · Spin-spin relaxation time (T2)
    • · Flow dynamics
    • · Chemical Shift

    Contrast agent use is restricted to the approved drug indications. When interpreted by a trained physician, these images vield information that can be useful in diagnosis.

    Device Description

    Not Found

    AI/ML Overview

    This document is a 510(k) clearance letter for the Vantage Elan 1.5T, MRT-2020, M-Power GX, a Magnetic Resonance Diagnostic Device. It states that the device is substantially equivalent to legally marketed predicate devices.

    However, the provided text does not contain the specific information requested regarding acceptance criteria, study details, sample sizes, ground truth establishment, or expert qualifications. The document focuses on the regulatory clearance and indications for use, without detailing the performance testing or clinical studies conducted to demonstrate substantial equivalence.

    Therefore, I cannot extract the requested information from the provided input.

    Ask a Question

    Ask a specific question about this device

    K Number
    K141472

    Validate with FDA (Live)

    Device Name
    VANTAGE ELAN
    Date Cleared
    2014-09-19

    (108 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Vantage Elan systems are indicated for use as a diagnostic imaging modality that produces cross-sectional transaxial, coronal, sagittal, and oblique images that display anatomic structures of the head or body. Additionally, this system is capable of non-contrast enhanced imaging, such as MRA.

    MRI (magnetic resonance imaging) images correspond to the spatial distribution of protons (hydrogen nuclei) that exhibit nuclear magnetic resonance (NMR). The NMR properties of body tissues and fluids are:

    • · Proton density (PD) (also called hydrogen density)
    • · Spin-lattice relaxation time (T1)
    • · Spin-spin relaxation time (T2)
    • Flow dynamics
    • · Chemical Shift

    Contrast agent use is restricted to the approved drug indications. When interpreted by a trained physician, these images yield information that can be useful in diagnosis.

    Device Description

    The Vantage Elan (Model MRT-2020) is a 1.5 Tesla Magnetic Resonance Imaging (MRI) System. The Vantage Elan uses 1.4m short and 4.1 tons light weight magnet. It includes the Toshiba Pianissimo™Σ technology (scan noise reduction technology). The design of the gradient coil and the whole body coil of the Vantage Elan provides the maximum field of view of 55 x 50 cm. The Model MRT-2020/A1 is without secondary cooling system and the Model MRT-2020/A2 is with secondary cooling system. The Vantage Elan MRI System is comparable to the current 1.5T EXCELART Vantage Titan MRI System (K120638), cleared Jun 1, 2012 with the following modifications.

    AI/ML Overview

    This document is a 510(k) premarket notification for the Vantage Elan (Model MRT-2020) Magnetic Resonance Imaging (MRI) System. The focus of the submission is to demonstrate substantial equivalence to a predicate device (EXCELART Vantage Titan MRI System, K120638) despite hardware and software changes.

    The document does not describe a study to prove acceptance criteria for a device with machine learning or AI components. Instead, it outlines the regulatory review process for a conventional medical imaging device. The "acceptance criteria" and "device performance" in this context refer to the device's conformance to established safety regulations, technical standards, and its ability to produce diagnostic-quality images.

    Therefore, for your request, I will interpret "acceptance criteria" as the performance and safety standards the device must meet, and "device performance" as how the Vantage Elan compared to these standards or to its predicate device. Since it's a traditional medical device submission, many of your requested items (like sample sizes for test sets, data provenance, ground truth establishment for AI models, MRMC studies, or standalone algorithm performance) are not applicable or explicitly mentioned in the context you've provided.

    Here is an analysis based on the provided text, addressing your points where possible:


    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Implied by Regulatory Standards & Predicate Comparison)Reported Device Performance (Vantage Elan vs. Predicate)
    Safety Parameters:
    - Whole body Maximum SAR (Specific Absorption Rate) conforming to IEC 60601-2-33 (2010), ≤ 4W/kg (1st operating mode)- 4W/kg for whole body (1st operating mode specified in IEC 60601-2-33 (2010))
    - Maximum dB/dt conforming to IEC 60601-2-33 (2010) (1st operating mode)- <1st operating mode specified in IEC 60601-2-33 (2010) (This is a change from the predicate's IEC 60601-2-33 (2002) but still meets the standard.)
    - Emergency shutdown mechanism for ferromagnetic object collision hazard- Shut down by Emergency Ramp Down Unit for collision hazard for ferromagnetic objects (Same as predicate)
    Imaging Performance:
    - Diagnostic imaging modality producing cross-sectional images of anatomic structures of head/body- Produces cross-sectional transaxial, coronal, sagittal, and oblique images that display anatomic structures of the head or body (Same indications for use as predicate)
    - Capability for non-contrast enhanced imaging (e.g., MRA)- Capable of non-contrast enhanced imaging, such as MRA (Same indications for use as predicate)
    - Ability to depict NMR properties (PD, T1, T2, Flow dynamics, Chemical Shift)- Image correspondence to NMR properties, useful for diagnosis when interpreted by a trained physician (Same as predicate)
    - Clinical image quality and functionality verification- Clinical image validation conducted using volunteers to verify image quality and functionality of the system. ("No change from the previous predicate submission (K120638).")
    - Conformance to applicable recognized consensus standards (e.g., NEMA MS series for MRI standards)- Conformance to listed standards (IEC, NEMA, etc.)
    Hardware Changes (Impact on Substantial Equivalence):
    - Main magnet (OR76 to TN150)- Changed from OR76 to TN150 (Evaluated for impact on performance and safety)
    - RF amplifier max power (20kW to 12kW)- Decreased from 20kW to 12kW (Evaluated for impact on performance and safety)
    - Max Gradient field strength (34mT/m to 33mT/m)- Changed from 34mT/m to 33mT/m (Evaluated for impact on performance and safety)
    - Max Slew Rate of gradient field (148mT/m/ms to 125mT/m/ms)- Changed from 148mT/m/ms to 125mT/m/ms (Evaluated for impact on performance and safety)
    - Patient aperture size (71cm to 63cm)- Changed from 71cm to 63cm (Evaluated for impact on performance and safety)
    - Number of units (7 to 5)- Reduced from 7 to 5 (Evaluated for impact on performance and safety)
    - Optical transmission of MR signals- New feature (Evaluated for impact on performance and safety)
    Software Changes (Impact on Substantial Equivalence):
    - SpineLine (automatic positioning assistance for spine)- New feature (Evaluated for impact on performance and safety)
    - 2D RMC (2D Real-time motion correction)- New feature (Evaluated for impact on performance and safety)
    - New operating system (Windows 7)- New operating system (Evaluated for impact on performance and safety)
    - ECG, peripheral pulse, and respiratory gating waveform display- New feature (Evaluated for impact on performance and safety)
    - Control for new hardware- New software to control new hardware (Evaluated for impact on performance and safety)

    Note: The primary "study" mentioned is comparison to the predicate device and conformance to recognized standards, rather than a clinical trial with specific performance metrics for novel AI features.

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: The document mentions "clinical image validation was conducted using volunteers." However, it does not specify the number of volunteers or images used in this validation.
    • Data Provenance: Not explicitly stated, but based on Toshiba Medical Systems Corporation being in Japan, and no mention of multi-center international data collection, the data provenance is likely prospective clinical data collected in Japan from volunteers.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • The document states, "When interpreted by a trained physician, these images yield information that can be useful in diagnosis." It does not specify the number or qualifications of experts involved in the "clinical image validation." This is a standard regulatory statement for diagnostic imaging.

    4. Adjudication method for the test set

    • Not specified. The document does not describe adjudication methods for the clinical image validation.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No. This is not an AI/ML device. The document describes a conventional MRI system. Therefore, an MRMC comparative effectiveness study regarding human readers improving with AI assistance is not applicable and was not conducted.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • No. This is not an AI/ML device. Therefore, a standalone algorithm performance study is not applicable and was not conducted.

    7. The type of ground truth used

    • For the "clinical image validation," the ground truth implicitly would be the diagnostic assessment by trained physicians based on the generated MRI images, likely correlated with other clinical information to confirm the accuracy of anatomical representation and diagnostic utility. There is no mention of pathology or outcomes data as direct ground truth for this device's specific validation.

    8. The sample size for the training set

    • Not applicable. This device is a conventional MRI system, not an AI/ML device, so there is no "training set" in the context of machine learning.

    9. How the ground truth for the training set was established

    • Not applicable. As above, there is no training set for an AI/ML model for this device.