510(k) Data Aggregation

    K Number
    K230983

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-10-20

    (197 days)

    Product Code
    Regulation Number
    876.5320
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Unicare is intended to provide electrical stimulation and neuromuscular re-education for the purpose of rehabilitation of weak pelvic floor muscles for the treatment of stress, urge and mixed urinary incontinence in women and to maintain urinary continence in women.

    Device Description

    Unicare is battery powered, single-channel, home-use electrical pelvic floor muscle stimulator. The device is supplied with a non-sterile, reusable (single-patient use) vaginal probe and self-adhesive electrodes which connect to the control unit by cable and plugs. The vaginal probe is inserted into the vagina. The optional self-adhesive electrodes is placed on patients' intact skin and is used for the treatment of only urge urinary incontinence in women. Electrical stimulation is delivered via the vaginal probe or the self-adhesive electrodes to the pelvic floor muscles. This electrical muscle stimulation works as a rehabilitation and training for pelvic floor muscles for the treatment of stress, urge and mixed urinary incontinence in women. The level of electrical stimulation of the Unicare can be controlled by the end user using manual push-button controls. This device is intended for over the counter (OTC) use.

    AI/ML Overview

    The provided document does not contain information related to software-based medical devices that would involve acceptance criteria, study details (sample size, data provenance, expert ground truth, adjudication, MRMC studies, standalone performance), or training set information as typically found for AI/ML-driven diagnostics.

    The document is an FDA 510(k) clearance letter for a non-implanted electrical continence device called "Unicare." This device is a hardware product that provides electrical stimulation for pelvic floor muscles. The "Non-Clinical Testing" section lists various engineering and safety tests performed on the device (biocompatibility, electrical safety, electromagnetic compatibility, software verification/validation, battery life), but these are standard engineering tests for hardware and software aspects of a physical device, not performance studies for an AI/ML algorithm or diagnostic tool.

    Therefore, I cannot extract the requested information regarding acceptance criteria and studies for device performance in the context of AI/ML or diagnostic accuracy from this document. The information requested (e.g., sample size for test set, data provenance, expert adjudication, MRMC studies, ground truth types) is specific to studies evaluating the performance of diagnostic algorithms, particularly those involving image analysis or similar AI/ML applications, which is not applicable to the "Unicare" device described.

    Ask a Question

    Ask a specific question about this device

    K Number
    K231053

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-08-18

    (127 days)

    Product Code
    Regulation Number
    882.5890
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview