510(k) Data Aggregation

    K Number
    K172571

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2017-09-22

    (25 days)

    Product Code
    Regulation Number
    870.1250
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The UltraScore Focused Force PTA Balloon is intended to dilate stenoses in the iliac, femoral, popliteal, infra-popliteal, and renal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also recommended for post dilatation of balloon expandable stents, and stent grafts in the peripheral vasculature.

    Device Description

    The ULTRASCORE™ Focused Force PTA Balloon consists of a flexible, over-the-wire (OTW) catheter shaft with a semi-compliant balloon fixed at the distal end. For all balloon lengths, radiopaque markers delineate the working length of the balloon and aid in balloon placement. For balloon lengths of 100 mm and greater, two radiopaque markers are positioned on the distal portion of the balloon and one radiopaque marker is positioned on the proximal portion of the balloon to differentiate between the distal and proximal ends of the catheter includes an atraumatic tip to facilitate advancement of the catheter to and through the stenosis. Two scoring wires, oriented 180° apart, provide focused force upon dilatation. The ULTRASCORE™ Focused Force PTA Balloon is compatible with 0.014" or 0.035" guidewires, as denoted by the product labeling. The distal portion of the 0.014" guidewire compatible catheters is hydrophilically coated. The proximal portion of the catheter includes a female luer lock hub connected to the catheter with a guidewire lumen and an inflation lumen. Packaged with every product is a protective sheath that is positioned over the balloon and must be removed prior to use. A stylet is placed into the tip of the catheter. These products are not made with natural rubber latex.

    AI/ML Overview

    This document describes a 510(k) submission for the ULTRASCORE™ Focused Force PTA Balloon (K172571). The device is being submitted as substantially equivalent to a previously cleared device, also named ULTRASCORE™ Focused Force PTA Balloon (K163420).

    Key Finding: This submission is for a device that is almost identical to its predicate, with the only change being a new formulation of PTFE on the scoring wires due to supplier discontinuance of the existing PTFE. Therefore, the "study" described is a series of non-clinical, in vitro tests to confirm the new formulation does not negatively impact performance or safety. There is no clinical study involving human participants described in this summary.

    Here's a breakdown of the requested information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategoryReported Device Performance
    Non-Clinical Performance
    ReinsertionMet All Predetermined Acceptance Criteria. (Specific criteria not detailed in this summary, but implies mechanical integrity and functionality after reinsertion.)
    Sheath CompatibilityMet All Predetermined Acceptance Criteria. (Specific criteria not detailed, but implies the device can be safely and effectively used with specified introducer sheaths without damage or hindrance.)
    Biocompatibility (ISO 10993-1:2009)
    CytotoxicityMet All Predetermined Acceptance Criteria. (Implies the device materials are not toxic to cells.)
    SensitizationMet All Predetermined Acceptance Criteria. (Implies the device materials do not cause allergic reactions.)
    Intracutaneous ReactivityMet All Predetermined Acceptance Criteria. (Implies the device materials do not cause irritation when in contact with tissue.)
    Acute Systemic ToxicityMet All Predetermined Acceptance Criteria. (Implies the device materials do not cause harmful effects via systemic exposure.)
    HemocompatibilityMet All Predetermined Acceptance Criteria. (Implies the device materials are compatible with blood and do not cause adverse blood reactions.)
    Material Mediated PyrogenicityMet All Predetermined Acceptance Criteria. (Implies the device materials do not cause fever.)
    ThrombogenicityMet All Predetermined Acceptance Criteria. (Implies the device materials do not promote the formation of blood clots.)

    2. Sample size used for the test set and the data provenance

    • Sample Size: The document does not specify the exact number of devices or samples used for each test. It refers to "the subject device" and its performance in various in vitro tests.
    • Data Provenance: The tests are described as in vitro. No human or clinical data is mentioned, so there is no country of origin or retrospective/prospective designation in this context. The testing was conducted internally as part of design verification and validation by the manufacturer, C.R. Bard, Inc. (Tempe, Arizona, USA).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • This question is not applicable to this submission. The "ground truth" for these in vitro engineering and biocompatibility tests is based on established scientific principles, standardized test methods (e.g., ISO 10993-1:2009 for biocompatibility), and internal engineering specifications/risk assessments, not expert consensus on medical images or patient outcomes.

    4. Adjudication method for the test set

    • This question is not applicable. Adjudication methods like 2+1 or 3+1 are used in clinical studies for resolving discrepancies in expert interpretations (e.g., image reading). The described tests are objective, measurable in vitro tests.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • This question is not applicable. No MRMC study was performed as this is a medical device (PTA Balloon), not an AI-powered diagnostic imaging device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • This question is not applicable. This is not an algorithm or AI device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • The "ground truth" for the non-clinical and biocompatibility testing is based on:
      • Applicable standards (e.g., ISO 10993-1:2009).
      • FDA Guidance Documents on non-clinical testing.
      • Internal Risk Assessment procedures.
      • Predetermined acceptance criteria derived from these standards and assessments.

    8. The sample size for the training set

    • This question is not applicable. There is no "training set" as this is not an AI/machine learning device.

    9. How the ground truth for the training set was established

    • This question is not applicable. No training set exists.
    Ask a Question

    Ask a specific question about this device

    K Number
    K163420

    Validate with FDA (Live)

    Date Cleared
    2017-06-14

    (190 days)

    Product Code
    Regulation Number
    870.1250
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The UltraScore Focused Force PTA Balloon is intended to dilate stenoses in the iliac, femoral, popliteal, infra-popliteal and renal arteries and for the treatment of obstructive or synthetic arteriovenous dialysis fistulae. This device is also recommended for post dilatation of balloon expanding stents, and stent grafts in the peripheral vasculature.

    Device Description

    The ULTRASCORE ™ Focused Force PTA Balloon consists of a flexible, over-the-wire (OTW) catheter shaft with a semi-compliant balloon fixed at the distal end. For all balloon lengths, radiopaque markers delineate the working length of the balloon and aid in balloon placement. For balloon lengths of 100 mm and greater, two radiopaque markers are positioned on the distal portion of the balloon and one radiopaque marker is positioned on the proximal portion of the balloon to differentiate between the distal and proximal ends of the balloon. The catheter includes an atraumatic tip to facilitate advancement of the catheter to and through the stenosis. Two scoring wires, oriented 180° apart, provide focused force upon dilatation. The ULTRASCORE ™ Focused Force PTA Balloon is compatible with .014" or .035" quidewires, as denoted by the product labeling. The distal portion of the .014" guidewire compatible catheters is hydrophilically coated. The proximal portion of the catheter includes a female luer lock hub connected to the catheter with a guidewire lumen and an inflation lumen. Packaged with every product is a protective sheath that is positioned over the balloon and must be removed prior to use. A stylet is placed into the tip of the catheter. These products are not made with natural rubber latex.

    AI/ML Overview

    The provided document describes the Bard Peripheral Vascular, Inc.'s UltraScore Focused Force PTA Balloon and its substantial equivalence to a predicate device, the VASCUTRAK® PTA Dilatation Catheter (K103459). The document focuses on demonstrating that the new device meets performance criteria similar to the predicate device and does not raise new safety or effectiveness issues.

    Here's a breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document lists numerous in vitro tests performed to demonstrate substantial equivalence, implying that acceptance criteria were met for each. However, specific numerical acceptance criteria or detailed performance results (e.g., a specific pressure rating, a defined trackability score) are not provided in this summary. The summary states, "The subject device, the ULTRASCORE™ Focused Force PTA Balloon, met all predetermined acceptance criteria of design verification and validation as specified by applicable standards, guidance, test protocols and/or customer inputs."

    Acceptance Criteria Category (Implied)Reported Device Performance (Implied)
    Dimensional CharacteristicsMet specifications for Balloon Outer Diameter, Balloon Working Length, Catheter Shaft Length.
    Balloon PerformanceMet specifications for Balloon Compliance, Inflation Time, Deflation Time, Rated Burst Pressure, Balloon Burst Mode, Balloon Fatigue (with and without stent/stent graft), Balloon Removal from Stent/Stent Graft.
    Marker PerformanceMet specifications for GEOALIGN® Gradient Marking Position, Legibility, Durability, Marker Band Radiopacity, Marker Band Alignment.
    Catheter FunctionalityMet specifications for Trackability, Sheath Compatibility, Guidewire Compatibility, Flushability, Reinsertion, Tip Taper, Device Compatibility.
    Material/Assembly IntegrityMet specifications for Hub Stress, Hub Torque, Balloon to Shaft Tensile, Tip to Wire Tensile, Catheter Elongation, Proximal Assembly Tensile.
    BiocompatibilityMet specifications for Cytotoxicity, Sensitization, Intracutaneous Reactivity, Acute Systemic Toxicity, Hemocompatibility, Material Mediated Pyrogenicity (in accordance with ISO 10993-1: 2009).
    Packaging IntegrityMet specifications for Packaging Pouch Tensile, Packaging Visual Inspection, Packaging Bubble Emission.

    2. Sample sizes used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document lists "in vitro tests" performed. There is no information provided about the sample sizes for these tests, the country of origin of the data, or whether it was retrospective or prospective. Given they are in vitro tests, the concept of "prospective" or "retrospective" data provenance typically applies more to human clinical studies rather than bench testing.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    The document describes in vitro (bench) testing. Therefore, the concept of "ground truth established by experts" in the clinical sense (e.g., radiologists, pathologists) is not applicable to the data presented. Ground truth for these tests would be derived from engineering specifications and standardized measurement techniques.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Since the tests are in vitro bench tests, clinical adjudication methods like "2+1" or "3+1" are not applicable. The "adjudication" would be based on comparison against predefined engineering acceptance criteria by qualified technicians or engineers performing the tests. No specific adjudication method for discrepancies in measurement is described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    There is no mention of a multi-reader multi-case (MRMC) comparative effectiveness study, nor any discussion of human readers or AI assistance. This document describes the a medical device (a PTA balloon catheter), not an AI diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This question is not applicable as the document describes a physical medical device (a balloon catheter), not an algorithm or AI system.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the in vitro tests conducted, the "ground truth" would be established by engineering specifications, standardized test methods, and measurement accuracy. For biocompatibility, it would be established by reference to international standards like ISO 10993-1:2009. The document does not refer to expert consensus, pathology, or outcomes data for establishing ground truth for these tests.

    8. The sample size for the training set

    This question is not applicable as the document describes a physical medical device and its predicate equivalence through bench testing, not a machine learning model requiring a training set.

    9. How the ground truth for the training set was established

    This question is not applicable as there is no training set mentioned or relevant to the device described.