510(k) Data Aggregation

    K Number
    K234142

    Validate with FDA (Live)

    Date Cleared
    2024-09-18

    (264 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TiGEN Abutment, PMMA Abutment and Scan Healing Abutment are intended for use on endosseous dental implants in the edentulous or partially edentulous maxilla or mandible, as an aid in prosthetic rehabilitation.

    The PMMA Abutment is indicated to be used pror to the final components to maintain, stabilize and shape the soft tissue during the healing plase. They must be placed out of occlusion and are for temporary use (3 months).

    For TiGEN Abutment and PMMA Abutment, all digitally designed abutments for use with PMMA Abutment and TiGEN Abutment are intended to be sent to a MegaGen-validated milling center for manufacture.

    Device Description

    The TiGEN Abutment is machined with the final prosthetic in accordance with the intraoral structure. It is machined by using dental CAD/CAM technology in accordance with customized patient's information in MegaGen-validated milling center. The TiGEN Abutment is made of Ti-6Al-4V ELI alloy. And It is provided with abutment screw. All TiGEN Abutment is provided non-sterile. The milled TiGEN Abutment must be sterilized by users prior to use.

    The PMMA Abutment is a temporary prosthesis used until the final prosthesis is placed for up to three months. The PMMA Post is machined with the temporary prosthetic in accordance with the intraoral structure by using dental CAD/CAM technology. The PMMA Cuff is made of Ti-6Al-4V ELI alloy and available in various gingival heights. The PMMA Post is made of Polymethyl methacrylate and available in various diameters and lengths so that it can be used according to individual patient conditions. All PMMA Abutment is provided non-sterile with abutment screw. The milled PMMA Abutment must be sterilized by users prior to use.

    The Scan Healing Abutment designed to aid in soft tissue contouring during the healing period after implant placement, creating an emergence profile for the final prosthesis. And they have the added design feature to be scannable an intraoral impression by digital scanner. The Scan Healing Abutment is provided with abutment screw and is provided gamma-sterile.

    AI/ML Overview

    This document pertains to a 510(k) premarket notification for dental implant abutments and does not contain information about an AI/ML medical device. Therefore, a table of acceptance criteria and a study proving the device meets the criteria, as requested by the prompt, cannot be extracted from the provided text for an AI/ML context.

    The document discusses the substantial equivalence of the "TiGEN Abutment, PMMA Abutment and Scan Healing Abutment" to already marketed predicate devices. The studies mentioned are primarily bench tests, biocompatibility evaluations, and sterilization/shelf-life validations, which are standard for physical medical devices. There is no mention of an AI/ML component, AI/ML device performance metrics, or related study methodologies like multi-reader multi-case (MRMC) studies.

    Without information on an AI/ML component, the requested details such as sample size for test sets (for AI), data provenance, expert ground truth establishment, MRMC studies, standalone AI performance, and training set details are not applicable and cannot be provided.