510(k) Data Aggregation

    K Number
    K062870

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2006-10-20

    (25 days)

    Product Code
    Regulation Number
    870.1250
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TriActiv FX® Embolic Protection System is indicated for use in conjunction with percutaneous coronary intervention (PCI), using a 7F guide catheter (without side holes), of diseased saphenous vein coronary bypass grafts ranging from 3.0mm to 5.0m in diameter. The TriActiv FX® Embolic Protection System is intended to protect the distal coronary vasculature by trapping and extracting thrombotic and atheromatous debris liberated during PCI.

    The safety and effectiveness of this device as an embolic protection system has not been established in the cerebral, carotid, or peripheral vasculature; native coronary arteries; or for treatment of patients with acute myocardial infarction.

    Device Description

    The TriActiv FX® Embolic Protection System is a temporary balloon occlusion embolic protection device used during percutaneous coronary intervention of diseased saphenous vein grafts ranging from 3.0mm to 5.0mm in diameter. The device is comprised of four principal components: ShieldWire™ Balloon Guidewire ("balloon guidewire), ShieldWire™ Inflator ("inflator"), FX™ Catheter ("flush catheter"), and AutoStream™ Flow Control ("flow control"). There are also four subcomponents or accessories included in the TriActiv FX® Embolic Protection the Split Tube Introducer, Shieldwire™ Guidewire Plug and Installer, System: TriActiv® Flow Control Power Supply and TriActiv® Tuohy. All TriActiv FX® Embolic Protection System components are supplied sterile and for single use only with exception of the TriActiv® Flow Control Power Supply which is non-sterile and reusable.

    The balloon guidewire is advanced through the hospital-supplied 7F guide catheter (without sideholes) prior to percutaneous coronary intervention of a saphenous vein araft (SVG) and positioned just past the target lesion. The balloon is inflated with a medical grade carbon dioxide gas blend, creating a protected space between the quide catheter and the balloon. Once the balloon is inflated and vessel occlusion is confirmed, PTCA and/or stenting can be performed over the balloon guidewire. Immediately after intervention, the flush catheter is loaded on the balloon guidewire and advanced into the graft. With the flush catheter positioned just proximal to the balloon, the flow control delivers saline through the flush catheter to gently wash the vessel and remove any debris generated during the intervention through the guide catheter into a collection bag. The TriActiv FX® Embolic Protection System has been designed to extract at a greater rate than it infuses to prevent aortic embolization. Once the physician is satisfied with the amount of debris removed from the vessel, the protection balloon is deflated and the device is removed.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study details for the TriActiv FX® Embolic Protection System, based on the provided 510(k) summary:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria for the TriActiv FX® Embolic Protection System were primarily established through a non-inferiority comparison to existing predicate devices (Medtronic Guardwire® or Boston Scientific Filterwire EX™). The key performance metrics are related to Major Adverse Cardiac Events (MACE) and other clinical outcomes.

    Metric (Acceptance Criteria)Reported Device Performance (TriActiv FX® - ASPIRE Study)Reference Device Performance (Guardwire® / Filterwire EX™ - PRIDE Study)Adjusted P-ValueUnadjusted Difference (95% CI)
    MACE to 30 days (Non-inferiority to predicate)3.2% (3/93)10.1% (32/318)0.013-6.8% (-2.7%)
    Myocardial Infarction (MI) (Lower rate desired)2.2% (2/93)8.8% (28/318)0.021-6.7% (-3.1%)
    Device Success⁴95.7% (89/93)94.5% (293/310)0.791.2% (-2.9%)
    Procedure Success/Patient⁵ (Criteria for successful procedure)97.8% (90/92)90.5% (286/316)0.0137.3% (3.6%)
    Lesion Success/Lesion⁶ (Criteria for successful lesion treatment)100% (103/103)99.4% (319/321)-0.6% (-0.1%)
    Final TIMI Flow 00% (0/97)0.6% (2/306)0.98-
    Final TIMI Flow 10% (0/97)0.6% (2/306)--
    Final TIMI Flow 24.1% (4/97)0.9% (3/306)--

    ⁴ Device success is defined as attainment of all of the following: the device was successfully delivered to the target location, the device operated as intended, the device was successfully retrieved.
    ⁵ Final stenosis < 50% by QCA for all lesions and no in-hospital MACE.
    ⁶ Final stenosis < 50% by QCA.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size (Test Set):
      • TriActiv FX® (ASPIRE Study): 93 patients in the Enrollment Phase (113 total patients enrolled, 20 were "roll-in" patients for training).
      • Control (PRIDE Study Active Control): 318 patients.
    • Data Provenance:
      • Country of Origin: The ASPIRE Study was conducted at 17 U.S. and 3 German investigational sites. The PRIDE Study data is referred to as "historical control data" and is implied to be from a similar multi-center, potentially international, context given the device manufacturers.
      • Retrospective or Prospective:
        • ASPIRE Study: Prospective, multi-center, non-randomized.
        • PRIDE Study Active Control: Retrospective (used as historical control data). The PRIDE study itself was likely prospective, but the data was utilized retrospectively for comparison in this 510(k).

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    The document does not specify the number of experts used to establish ground truth or their qualifications. The outcomes (e.g., MACE, MI) are clinical endpoints based on patient diagnosis and objective measurements, likely adjudicated by physicians involved in the studies, but specific details on an adjudication committee or expert panel for ground truth are not provided in this summary.

    4. Adjudication Method for the Test Set

    The document does not explicitly describe an adjudication method for the test set (e.g., 2+1, 3+1). Clinical events like MACE and MI are typically adjudicated by an independent clinical events committee in large trials, but this specific detail is not present in the summary.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. This device is an embolic protection system, a physical medical device, not an AI or imaging diagnostic tool that would typically involve "human readers" or "AI assistance." The study evaluates the device's clinical performance in preventing adverse events during a procedure.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Not Applicable. This is a physical medical device, not a software algorithm. Therefore, "standalone" algorithm performance is not relevant.

    7. The Type of Ground Truth Used

    The ground truth for evaluating the device's performance was based on clinical outcomes data. Specifically, it included:

    • Major Adverse Cardiac Events (MACE)
    • Death (Cardiac, Non-Cardiac)
    • Myocardial Infarction (MI) (Q wave, Non-Q wave)
    • Target Vessel Revascularization (TVR)
    • Stroke
    • Hemorrhagic/vascular complications
    • Transfusion
    • Device Success (defined by successful delivery, operation, and retrieval)
    • Procedure Success/Patient (defined by final stenosis < 50% by QCA and no in-hospital MACE)
    • Lesion Success/Lesion (defined by final stenosis < 50% by QCA)
    • Final TIMI Flow

    These are direct clinical endpoints and objective measurements taken during and after the intervention.

    8. The Sample Size for the Training Set

    The document refers to "roll-in" patients for training purposes within the ASPIRE study:

    • Training Set Size: 20 patients (out of 113 total enrolled in ASPIRE). These were for "training purposes" for the investigators, not for training a machine learning model.

    9. How the Ground Truth for the Training Set Was Established

    For the 20 "roll-in" patients, the ground truth was established through standard clinical evaluation and reporting of outcomes, similar to the main study patients. However, their data was likely not included in the primary efficacy analysis for statistical rigor, as their purpose was for investigator training/familiarization with the device. This "training" refers to human operators learning to use the device, not a machine learning model.

    Ask a Question

    Ask a specific question about this device

    K Number
    K061772

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2006-07-11

    (18 days)

    Product Code
    Regulation Number
    870.1250
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TriActiv FX® Embolic Protection System is indicated for use in conjunction with percutaneous coronary intervention (PCI), using a 7F guide catheter (without side holes), of diseased saphenous vein coronary bypass grafts ranging from 3.0mm to 5.0m in diameter. The TriActiv FX® Embolic Protection System is intended to protect the distal coronary vasculature by trapping and extracting thrombotic and atheromatous debris liberated during PCI.

    The safety and effectiveness of this device as an embolic protection system has not been established in the cerebral, carotid, or peripheral vasculature; native coronary arteries; or for treatment of patients with acute myocardial infarction.

    Device Description

    The TriActiv FX® Embolic Protection System is a temporary balloon occlusion embolic protection device used during percutaneous coronary intervention of diseased saphenous vein grafts ranging from 3.0mm to 5.0mm in diameter. The device is comprised of four principal components: ShieldWire™ Balloon Guidewire ("balloon guidewire), ShieldWire™ Inflator ("inflator"), FX™ Catheter ("flush catheter"), and AutoStream™ Flow Control ("flow control"). There are also four subcomponents or accessories included in the TriActiv FX® Embolic Protection System: the Split Tube Introducer, Shieldwire™ Guidewire Plug and Installer, TriActiv® Flow Control Power Supply and TriActiv® Tuohy. All TriActiv FX® Embolic Protection System components are supplied sterile and for single use only with exception of the TriActiv® Flow Control Power Supply which is non-sterile and reusable.

    AI/ML Overview

    The provided text describes the TriActiv FX® Embolic Protection System and its clinical evaluation, but it does not include a table of acceptance criteria or explicitly state acceptance criteria for device performance. It focuses on demonstrating non-inferiority to a predicate device based on clinical outcomes.

    However, based on the clinical study results presented, we can infer what the implicit performance goals or "acceptance criteria" likely were, particularly in relation to the predicate device.

    Here's an attempt to structure the information based on your request, inferring where explicit details are missing:


    1. Table of Acceptance Criteria and Reported Device Performance

    Since explicit acceptance criteria are not presented in a table in the submission, the table below infers the performance goals based on the non-inferiority study results compared to the predicate. The "Acceptance Criteria" here are derived from the need to demonstrate non-inferiority to the Active Control Arm of the PRIDE Trial (using Guardwire® Plus System or FilterWire® EX System).

    Performance MetricAcceptance Criteria (Implied for Non-Inferiority)Reported Device Performance (ASPIRE Enrollment Phase)Did the Device Meet Criteria?
    Major Adverse Cardiac Events (MACE) to 30 daysNon-inferior to predicate (Active Control Arm MACE rate: 10.1%)3.2% (3/93)Yes (p<0.001 for non-inferiority, Difference -6.8% with upper 95% C.I. -2.7%)
    Myocardial Infarctions (MI)Non-inferior to predicate (Active Control Arm MI rate: 8.8%)2.2% (2/93)Yes (p=0.021 for non-inferiority, Difference -6.7% with upper 95% C.I. -3.1%)
    Device SuccessNon-inferior to predicate (Active Control Arm Device Success: 94.5%)95.7% (89/93)Yes (p=0.79 for non-inferiority, Difference 1.2% with -2.9% 95% CB)
    Procedure Success/PatientNon-inferior to predicate (Active Control Arm Procedure Success/Patient: 90.5%)97.8% (90/92)Yes (p=0.013 for non-inferiority, Difference 7.3% with 3.6% 95% CB)
    Lesion Success/LesionNon-inferior to predicate (Active Control Arm Lesion Success/Lesion: 99.4%)100% (103/103)Yes (Difference 0.6% with -0.1% 95% CB)
    Final TIMI Flow (TIMI 3)Non-inferior to predicate (Active Control Arm TIMI 3 Flow: 97.8%)95.9% (93/97)The p-value (0.98) suggests no significant difference, supporting non-inferiority.

    Study Proving Device Meets Acceptance Criteria:

    The study that proves the device meets (or in this case, is non-inferior to) these criteria is the ASPIRE (Angioplasty in SVGs with Post Intervention Removal of Embolic Debris) Study.

    2. Sample Size and Data Provenance for the Test Set

    • Sample Size (Test Set): 93 patients (Enrollment Phase of the ASPIRE Study).
    • Data Provenance: Prospective, multi-center, non-randomized study conducted at 17 U.S. and 3 German investigational sites. Historical control data (318 patients) was used from the PRIDE Study (Active Control group: Medtronic Guardwire® or Boston Scientific Filterwire EX™).

    3. Number of Experts and Qualifications for Ground Truth (Test Set)

    The document does not explicitly state the number of experts used to establish ground truth or their specific qualifications (e.g., "radiologist with 10 years of experience"). Clinical trials like ASPIRE typically involve:

    • Investigating physicians: Board-certified interventional cardiologists are implicitly the "experts" performing the procedures and making clinical assessments that contribute to endpoint determination (e.g., MACE, MI).
    • Clinical Events Committee (CEC): Often, clinical events in such studies are adjudicated by an independent CEC composed of qualified physicians (e.g., cardiologists) from diverse backgrounds to ensure unbiased endpoint classification. The document does not explicitly mention a CEC, but it's a standard practice for studies of this nature.

    4. Adjudication Method for the Test Set

    The document does not explicitly describe an adjudication method (e.g., 2+1, 3+1) for the test set. However, the reference to "adjusted based on subclassifications from a propensity score analysis" and comparison to a historical control group suggests a statistical approach to account for potential confounding factors rather than a specific expert adjudication model for individual case diagnosis. Clinical event definitions (e.g., for MACE, MI) would have been pre-specified in the study protocol, and their occurrence likely determined by the clinical investigators and potentially confirmed by an independent committee.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. This study focuses on clinical outcomes in patients, comparing the device's performance to a historical control group, rather than evaluating human reader performance with or without AI assistance.

    6. Standalone (Algorithm Only) Performance Study

    No, a standalone (algorithm only) performance study was not done. The TriActiv FX® Embolic Protection System is a medical device (physical system for embolic protection), not an AI algorithm. The study evaluated the clinical performance of the device in vivo during PCI procedures.

    7. Type of Ground Truth Used

    The "ground truth" for the clinical study was based on clinical outcomes data from patients, including:

    • Major Adverse Cardiac Events (MACE) - a composite endpoint typically including death, MI, and target vessel revascularization (TVR).
    • Individual clinical events such as MI (Q wave and non-Q wave), death (cardiac and non-cardiac), stroke, hemorrhagic/vascular complications.
    • Device success, procedure success, and lesion success, which are defined by criteria related to the technical performance of the device and immediate post-procedure findings (e.g., final stenosis by QCA, TIMI flow).

    These outcomes are collected and reported by clinical investigators in accordance with the study protocol.

    8. Sample Size for the Training Set

    The document does not mention a "training set" in the context of an algorithm or AI. Since this is a physical medical device, there is no algorithm training set. The "training" referred to in the document is for the human investigators learning to use the device: "Investigators in the study were allowed up to 3 'roll-in' patients, for training purposes, which accounted for 20 of the 113 patients." These "roll-in" patients were excluded from the primary efficacy analysis (N=93).

    9. How Ground Truth for the Training Set Was Established

    As there is no algorithm training set, this question is not applicable. The "roll-in" patients were used for physician training, and their outcomes were not part of the primary efficacy analysis.

    Ask a Question

    Ask a specific question about this device