Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K203760

    Validate with FDA (Live)

    Date Cleared
    2021-05-25

    (153 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TOKUYAMA UNIVERSAL BOND II is indicated for:

    • Direct anterior and posterior restorations with light-curing, dual-curing, and self-curing composite materials
    • Intraoral repair of composite restorations, porcelain fused to metal, metal, and all-ceramic restorations without an additional primer
    • Cementation of indirect restorations and veneers when combined with light-cure, dual-cure, and self-curing resin cements
    • Bonding of core build-ups made of core build-up materials
    • Bonding of denture resin to metal base, clasp or attachment
    • Repair of denture with metal base, clasp or attachment
    • Bonding of opaque resin to a metal base in the fabrication of resin-faced crowns
    Device Description

    The TOKUYAMA UNIVERSAL BOND II device is a two-component self-cured dental adhesive system for both direct and indirect restorations that can be used with self-etch, selective-enamel-etch and total-etch techniques. As a universal adhesive, TOKUYAMA UNIVERSAL BOND II has been designed to be fully compatible with light-cured, self-cured and dual-cured composite materials.
    TOKUYAMA UNIVERSAL BOND II contains phosphoric acid monomer, bisphenol A di(2-hydroxy propoxy) dimethacrylate (Bis-GMA), triethylene glycol dimethacrylate (TEGDMA), 2-Hydroxyethyl methacrylate (HEMA), MTU-6 (thiouracil monomer), silane coupling agent, peroxide, borate catalyst, acetone, ethanol and purified water.
    Bond A and Bond B are packaged in separate plastic bottles. A group of polymerization agents is contained in the Bond A and Bond B to avoid reaction during storage, and the polymerization reaction begins upon mixing. When the mixture is applied thinly to adherends and concentrated by air-drying, a cured layer is formed by polymerization of methacrylic monomers. The cured layer functions as an adhesive layer for enhancing adhesiveness of polymerization resin to the adherends.
    The device improves the bond strength of polymerizable resin material (adhesive resin cement, acrylic resin, and composite resin) to indirect restorative materials such as glass-ceramics (porcelain), oxide-ceramics (zirconia and alumina), metals (precious and non-precious), and resin materials including inorganic filler.
    The TOKUYAMA UNIVERSAL BOND device does not come sterilized and is not intended to be sterilized prior to use.

    AI/ML Overview

    The provided document describes the TOKUYAMA UNIVERSAL BOND II, a dental adhesive. The acceptance criteria and the study to prove the device meets these criteria are outlined through non-clinical testing.

    1. Table of Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (In-house specification derived from predicate device)Reported Device Performance (TOKUYAMA UNIVERSAL BOND II)
    Enamel: ≥ 12 MPaPerformance met or exceeded this value (implied by "Similar" in comparison table and "concluded that the TOKUYAMA UNIVERSAL BOND II device is substantially equivalent to the primary predicate device"). Specific values are not provided in the summary.
    Dentin: ≥ 10 MPaPerformance met or exceeded this value (implied). Specific values are not provided in the summary.
    Metal: ≥ 12 MPaPerformance met or exceeded this value (implied). Specific values are not provided in the summary.
    Porcelain: ≥ 10 MPaPerformance met or exceeded this value (implied). Specific values are not provided in the summary.
    Zirconia: ≥ 10 MPaPerformance met or exceeded this value (implied). Specific values are not provided in the summary.
    Resin material including inorganic filler: ≥ 10 MPaPerformance met or exceeded this value (implied). Specific values are not provided in the summary.
    Working time: Not cured after three minutesDevice was confirmed not cured after three minutes.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document does not explicitly state the sample sizes (number of replicates or specimens) used for each tensile bond strength test. However, it indicates that testing was conducted pursuant to Section 5.1 of ISO/TS 11405:2015. This ISO standard typically specifies details on sample preparation and testing procedures.

    The data provenance is not explicitly stated in terms of country of origin, but the submitting company is Tokuyama Dental Corporation, located in Tokyo, Japan. The testing is non-clinical bench testing, so it is retrospective in the sense that it evaluates the manufactured device's performance.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    Not applicable. This is a non-clinical bench testing study for a dental adhesive, not a study involving diagnostic interpretation or human expert judgment to establish ground truth for a test set. The ground truth for performance is objective physical measurements based on established ISO standards.

    4. Adjudication Method for the Test Set:

    Not applicable. As noted above, this is non-clinical bench testing with objective physical measurements. There is no subjective adjudication required.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    Not applicable. This is a non-clinical study for a dental adhesive, not an AI-assisted diagnostic device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Not applicable. This is a non-clinical study for a dental adhesive, not an algorithm. The device's performance is measured standalone from human intervention other than its application as per the instructions for use.

    7. The Type of Ground Truth Used:

    The ground truth used for performance evaluation is objective physical measurements of tensile bond strength and working time, compared against pre-defined in-house specifications (derived from the predicate device) and ISO standards. Biocompatibility was also assessed in accordance with ISO 10993-1:2009.

    8. The Sample Size for the Training Set:

    Not applicable. This device is a dental adhesive, not an AI/ML algorithm that requires a training set.

    9. How the Ground Truth for the Training Set Was Established:

    Not applicable. As this is not an AI/ML algorithm, there is no training set or associated ground truth establishment process.

    Ask a Question

    Ask a specific question about this device

    K Number
    K171226

    Validate with FDA (Live)

    Date Cleared
    2017-11-28

    (216 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TOKUYAMA UNIVERSAL BOND is indicated for:

    • Direct anterior and posterior restorations with light-curing, and self-curing composite materials

    • Intraoral repair of composite restorations, porcelain fused to metal, and all-ceramic restorations without an additional primer

    • Cementation of indirect restorations and veners when combined with light-cure, and self-curing resin cements

    • Bonding of core build-ups made of core build-up materials

    • Bonding of denture resin to metal base, clasp or attachment

    • Repair of denture with metal base, clasp or attachment

    • Bonding of opaque resin to a metal base in the fabrication of resin-faced crowns

    Device Description

    The TOKUYAMA UNIVERSAL BOND device is a two-component self-cured dental adhesive system for both direct and indirect restorations that can be used with self-etch, selective-enamel-etch, and total-etch techniques. The TOKUYAMA UNIVERSAL BOND device is fully compatible with light-cured. self-cured, and dual-cured composite materials.

    Bond A and Bond B are packaged in separate plastic bottles. A group of polymerization agents is contained in the Bond A and Bond B to avoid reaction during storage, and the polymerization reaction begins upon mixing. When the mixture is applied thinly to adherends and concentrate by air-drying, a cured layer is formed by polymerization of methacrylic monomers. The cured layer functions as an adhesive layer for enhancing adhesiveness of polymerization resin to the adherends.

    The device improves the bond strength of polymerizable resin material (adhesive resin cement, acrylic resin, and composite resin) to indirect restorative materials such as glass-ceramics (porcelain), oxide-ceramics (zirconia and alumina), metals (precious and non-precious), and resin materials including inorganic filler.

    AI/ML Overview

    The provided document is a 510(k) premarket notification for a dental adhesive device, the TOKUYAMA UNIVERSAL BOND. It describes the device, its intended use, technological characteristics, and non-clinical testing performed to demonstrate substantial equivalence to predicate devices.

    However, the document does NOT describe an AI/ML-based medical device. Therefore, it does not contain the information required to answer the questions about acceptance criteria, study design for AI models (sample size, data provenance, ground truth, expert adjudication, MRMC studies, standalone performance, training set details).

    The Acceptance Criteria and Study Proof for the TOKUYAMA UNIVERSAL BOND device are entirely based on physical property testing as it is a material-based dental product, not an AI diagnostic or assistance tool.

    Here's a summary of the acceptance criteria and proof as presented for this specific dental device:

    Acceptance Criteria and Reported Device Performance

    The acceptance criteria for the TOKUYAMA UNIVERSAL BOND device are based on achieving certain tensile bond strengths to various dental materials, as well as satisfactory working time, paintability, and appearance.

    Acceptance Criteria ItemAcceptance Criteria (In-house Specification)Reported Device Performance (TOKUYAMA UNIVERSAL BOND)
    Tensile bond strength to enamel> 12 MPa> 12 MPa
    Tensile bond strength to dentin> 10 MPa> 10 MPa
    Tensile bond strength to metal> 12 MPa> 12 MPa
    Tensile bond strength to porcelain≥ 10 MPa≥ 10 MPa
    Tensile bond strength to zirconia≥ 10 MPa≥ 10 MPa
    Tensile bond strength to resin material including inorganic filler≥ 10 MPa≥ 10 MPa
    Working timeCured after 90 seconds (Confirmation)Confirmed to be cured after 90 seconds
    PaintabilityEven film formed (Evaluation)Even film formed
    AppearanceVisual inspection (Normal)Normal

    (Note: The tables in the original document present the performance of the predicate and reference devices against the same specifications, with all devices meeting these criteria.)

    Study that Proves the Device Meets the Acceptance Criteria:

    The study conducted is a series of non-clinical, benchtop physical property tests.

    1. Sample size used for the test set and data provenance:

      • The document does not explicitly state the sample size (number of individual samples or replicates tested) for each physical property. It only states that "Non-clinical testing of the following physical properties was conducted."
      • Data Provenance: The tests were conducted by Tokuyama Dental Corporation, based in Japan. This implies the data originates from their internal laboratory testing. The data is retrospective in the sense that it was generated prior to the 510(k) submission.
    2. Number of experts used to establish the ground truth for the test set and qualifications of those experts:

      • Not applicable. For physical property testing of a dental material, "ground truth" is established by the direct measurement of physical properties (e.g., bond strength in MPa) using established testing standards (ISO/TS 11405:2015). This does not involve human expert adjudication or consensus in the way an AI diagnostic would require for image interpretation.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • Not applicable. As this is a physical property test, not an interpretive one, there is no adjudication process involving multiple human readers. The measurement results are directly compared against the pre-defined in-house specifications.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • Not applicable. This device is a material, not an AI or a system that assists human readers. Therefore, an MRMC study is irrelevant.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Not applicable. This device has no algorithm and does not perform any diagnostic or interpretive function. Its performance is intrinsic to its physical and chemical properties.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

      • The "ground truth" for this device's performance is the direct, quantitative measurement of physical properties (tensile bond strength) and qualitative assessments (working time, paintability, appearance) against pre-defined, standardized specifications. The testing was conducted pursuant to Section 5.1 of ISO/TS 11405:2015 for tensile bond strength tests.
    7. The sample size for the training set:

      • Not applicable. This is not an AI/ML device, so there is no "training set."
    8. How the ground truth for the training set was established:

      • Not applicable. There is no training set for this type of device.

    In summary, the provided document pertains to a dental bonding agent, and therefore the "acceptance criteria" and "proof" relate to its physical and chemical characteristics and performance as a material, rather than the statistical or clinical performance metrics associated with AI/ML medical devices.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1