Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K050705

    Validate with FDA (Live)

    Device Name
    TIUNITE IMPLANTS
    Manufacturer
    Date Cleared
    2005-05-19

    (62 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Nobel Biocare TiUnite® Implants are root-form endosseous implants intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as an artificial tooth, in order to restore patient esthetics and chewing function. Nobel Biocare TiUnite® Implants are indicated for single or multiple unit restorations in splinted or non-splinted applications. Nobel Biocare TiUnite® Implants may be placed immediately and put into immediate function providing that the initial stability requirements detailed in the surgical manuals are satisfied.

    TiUnite® implants are indicated for use in soft bone whenever immediate or early loading is applied. The TiUnite® implants are preferred in these soft bone indications because bone formation is more rapid and greater than on machined surface implants resulting in better maintenance of initial implant stability, faster and stronger osseointegration, and higher success rates.

    Device Description

    Nobel Biocare TiUnite" Implants are threaded, root-form dental implants intended for use in the upper and/or lower jaw to support prosthetic devices, such as artificial teeth, in order to restore patient esthetics and chewing function to partially or fully edentulous patients.

    Til hite Implants machined from titanium and have a surface treatment consisting of a thin, uniform titanium oxide (TiUnite") layer. Nobel Biocare TiUnite Implants are available with a straight or tapered contour.

    Nobel Biocare TiUnite" Implants may be placed in the oral cavity using either a single stage surgical procedure or a two stage surgical procedure. If a single stage procedure is used, the implants may be immediately loaded following insertion where good initial stability can be obtained.

    Due to a more rapid formation and greater amount of bone to implant contact during healing. Nobel Biocare's TiUnites surfaced implants result in faster and stronger ossecuntegration and better maintenance of the initial implant stability than machined titanium implants. When piaced in soft bone and immediately loaded, the faster and stronger osseointegration of Nobel Biocare's TiUnites surfaced implant results in a higher success rate compared to machined implants

    AI/ML Overview

    The provided document is a 510(k) summary for the TiUnite Implants by Nobel Biocare. This submission is for a dental implant, which is a medical device. The information requested in the prompt (acceptance criteria, study details, sample sizes, ground truth establishment, expert qualifications, adjudication methods, MRMC studies, standalone performance, and training set details) is typically associated with the evaluation of artificial intelligence (AI) or diagnostic image analysis devices.

    This 510(k) summary for a dental implant does not contain any information related to AI/ML device performance or clinical studies with human readers. It is a regulatory submission demonstrating substantial equivalence to a predicate device based on material, design, and intended use, not on diagnostic performance against a ground truth.

    Therefore, I cannot extract the requested information from the provided text because it is not present in this type of regulatory document.

    Here's why the requested information is not applicable or available:

    • Acceptance Criteria & Reported Device Performance (Table): This document describes a physical medical device (dental implant). Its "performance" is related to its mechanical properties, biocompatibility, and clinical outcomes (osseointegration, stability, success rates), not diagnostic accuracy metrics like sensitivity or specificity that would have acceptance criteria for an AI device.
    • Sample Size, Data Provenance, Experts, Adjudication, MRMC, Standalone Performance: These are all related to studies designed to evaluate the diagnostic accuracy, reliability, or clinical effectiveness of a diagnostic or AI-powered device, often in comparison to human readers or a ground truth. The TiUnite implant is a therapeutic device, not a diagnostic one, and its 510(k) submission does not include such performance studies.
    • Type of Ground Truth: Ground truth (e.g., pathology, expert consensus) is established for AI or diagnostic devices to verify their output. This is not relevant for a dental implant's regulatory submission.
    • Sample Size for Training Set & Ground Truth for Training Set: These relate to the development and validation of AI models, which are not part of this dental implant submission.

    In summary, the provided text does not contain the information requested because it pertains to a traditional medical device (dental implant) and not an AI or diagnostic image analysis device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1