Found 2 results

510(k) Data Aggregation

    K Number
    K124051

    Validate with FDA (Live)

    Device Name
    THE VAULT SYSTEM
    Date Cleared
    2013-05-17

    (137 days)

    Product Code
    Regulation Number
    892.2050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The VAULT® System is intended for use as a software interface and image manipulation system for the transfer of imaging information from a medical scanner such as Computerized Axial Tomography (CT) or Magnetic Resonance Imaging (MRI). It is also intended as pre-operative software for simulating/evaluating implant placement and surgical treatment options. The physician chooses the out-put data file for printing and/or subsequent use in CAD modeling or CNC/Rapid-prototyping.

    Device Description

    The VAULT® System software described here was developed in conformance with reference to the FDA Guidance Document for Industry "Guidance for the Submission of Premarket Notifications for Medical Image Management Devices, July 27, 2000". Based on the information contained in Section G of that document, a final determination of submission content was developed. A secondary reference entitled "Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices. May 11, 2005 was also used and resulted in a determination of a "MODERATE" level of concern for the software.

    The UAULT® System software is made available to the user via a web-accessed software interface. The program is a surgeon directed surgical planning package primarily but not exclusively directed at trauma and orthopedic indications. After secure log-in the user requests, creates, reviews and finally authorizes their desired surgical plan. When authorizing, the surgeon/user may choose additional options such as implant sizing and/or various file output options.

    AI/ML Overview

    The VAULT® System Surgery Planning Software received 510(k) clearance (K124051) from the FDA. The submission focused on demonstrating substantial equivalence to predicate devices (Mimics Software - K073468 and TraumaCAD Software- K073714) rather than a direct study against predefined acceptance criteria for a novel device. The performance data was evaluated through non-clinical testing.

    Here's an breakdown based on the provided document:

    1. Table of Acceptance Criteria and Reported Device Performance

    Since this is a 510(k) submission demonstrating substantial equivalence, explicit "acceptance criteria" in the sense of predefined thresholds for diagnostic performance metrics (like sensitivity, specificity, AUC) are not presented in the same way as for a novel diagnostic AI device. Instead, the "acceptance criteria" are implied by the functional and safety requirements defined for the VAULT® System and its performance being "equivalent" to the predicates.

    Feature/RequirementAcceptance Criteria (Implied)Reported Device Performance
    Functional Equivalence
    Image TransferTransfer imaging information from CT/MRI scanners.The VAULT® System is intended for use as a software interface and image manipulation system for the transfer of imaging information from a medical scanner such as Computerized Axial Tomography (CT) or Magnetic Resonance Imaging (MRI).
    Preoperative PlanningSimulate/evaluate implant placement and surgical treatment options.It is also intended as pre-operative software for simulating/evaluating implant placement and surgical treatment options.
    Output File GenerationPhysician chooses output data file for printing/CAD modeling/CNC/Rapid-prototyping.The physician chooses the out-put data file for printing and/or subsequent use in CAD modeling or CNC/Rapid-prototyping. Additional options include implant sizing and/or various file output options.
    DICOM Image UseUse DICOM images.Yes, uses DICOM images (from feature comparison table). Digital file image upload controlled by DICOM process met specifications. The VAULT® System performs initial conversion of image files to graphical formats (JPEG, BMP, PNG, TIFF) before planning, an improvement over predicates which convert post-plan.
    Overlays & TemplatesSupport overlays and templates.Yes, supports overlays and templates (from feature comparison table).
    Accuracy & Integrity
    Anatomical Model TestingRequired level of accuracy and functionality for anatomical and phantom models.Anatomical and phantom model digital file testing demonstrated the required level of accuracy and functionality.
    Image File IntegrityImage file integrity, accuracy, and suitability after conversion, save, and transfer operations.Image file integrity, accuracy and suitability following required conversion, save and transfer operations met all specifications.
    Image Calculations & MeasurementCalculations & measurement of anatomic features and landmarks meet specifications.Image calculations & measurement of anatomic features and landmarks meets specifications.
    SafetyAbsence of control over life-saving devices; adherence to safety risk/hazard analysis.Does not control life-saving devices (from feature comparison table). Safety requirements were developed using a safety risk/hazard analysis based on ISO 14971:2007 approach.
    Software ValidationTraceability, boundary values, and stress testing as per FDA guidance.Functional requirements as defined by the VAULT® System Software Requirements Specification (SRS) were tested and traceability was performed and documented using FDA's General Principles of Software Validation guidance document. Validation included boundary values and stress testing as defined by the FDA's Guidance for the Content of Premarket Submission for Software Contained in Medical Devices guidance document.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not specify a distinct "test set" with a particular sample size of patient data. The non-clinical performance data relied on:

    • "Anatomical and phantom model digital file testing": The exact number of models used is not specified.
    • The testing of various software functionalities (DICOM process, image file integrity, calculations, measurements).

    The data provenance is not explicitly stated as country of origin or retrospective/prospective data for a clinical study. The testing appears to be primarily software functional and performance testing using internal data (anatomical and phantom models) rather than a large clinical dataset.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    The document does not describe the use of human experts to establish ground truth for a diagnostic test set in the conventional sense. The "ground truth" for the software's performance seems to be based on:

    • Specifications: Whether the software performed according to its defined functional and safety specifications ("met specifications").
    • Accuracy against known physical/digital models: For anatomical and phantom model testing, the "ground truth" would be the known parameters of these models.

    There are no details provided about experts involved in establishing this "ground truth" or their qualifications.

    4. Adjudication Method for the Test Set

    Not applicable. The document does not describe an adjudication method as would be used for a clinical study involving human readers or interpretation of results. The testing was focused on meeting software specifications.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No, an MRMC comparative effectiveness study involving human readers with and without AI assistance was not described or conducted. This submission focused on the functional equivalence of the software to existing predicate devices.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Yes, the performance testing described is essentially "standalone" in the sense that it evaluates the software's inherent functions (image processing, calculations, file handling) without explicitly measuring its impact on human reader performance or a human-in-the-loop scenario. The assessment is of the software itself fulfilling its defined requirements.

    7. The Type of Ground Truth Used

    The ground truth used for testing appears to be primarily:

    • Software Specifications: The software's ability to "meet specifications" for various functions (DICOM process, image integrity, calculations, measurements).
    • Reference Data/Models: For "anatomical and phantom model digital file testing," the ground truth would be the known, accurate parameters of these models against which the software's output was compared.

    It does not mention ground truth derived from expert consensus, pathology, or outcomes data in a clinical trial setting.

    8. The Sample Size for the Training Set

    The document does not describe a "training set" in the context of machine learning or AI algorithm development. The VAULT® System appears to be a rule-based or traditional image processing software rather than an AI/ML-driven device that requires training data. No training set size is mentioned.

    9. How the Ground Truth for the Training Set was Established

    Not applicable, as a training set for machine learning is not mentioned or implied by the device's description or the validation approach.

    Ask a Question

    Ask a specific question about this device

    K Number
    K990936

    Validate with FDA (Live)

    Device Name
    THE VAULT
    Date Cleared
    1999-05-18

    (60 days)

    Product Code
    Regulation Number
    880.5570
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vault is a single-use, disposable, non-sterile sharps transport container intended to be used by Paramedics and EMT's in their medical jump kits where larger sharps containers are not conveniently accessible. Its function is to be available for portable sharps containment as an alternative to using non-sharps containers or resheathing a needle with its original protective cover.

    Device Description

    The VAULT is a single-use , disposable , non-sterile, sharps transport container intended to be used in areas where larger sharps containers are not conveniently accessible, normally in the field use in paramedic and EMT jump kits. The Vaults design allows for easy one handed use by the EMT. Its function is to be available for portable sharps containment and as a alternative to using non-sharps containers or resheathing a needle with its original protective cover.

    The VAULT is a 1.5x 5 inch box designed to set horizontally in a jump kit. The lid is designed to remain open until use and then permanently close for transportation of the contaminated sharps for safe disposal.

    Each box is labeled with a biohazard label. The VAULT is also a bright red color to meet OSHA standards for warning of biohazard danger.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and study information for "The VAULT" device, based on the provided text:

    Acceptance Criteria and Reported Device Performance

    Acceptance CriterionReported Device Performance
    Impact ResistanceThe box was filled with needles and dropped from a height of 8 feet onto a concrete floor resulting in NO visible damage to box and NO needle ejection.
    Puncture ResistancePuncture resistance was tested by weighted pressure to needles on different box parts. Numerous tests resulted in the needles bending before they would puncture box. Pressure tested all parts of the box exceeded 7 lbs. of weight. These tests indicate the VAULT is very puncture resistant.
    Overfill DetectionThe box is designed with a horizontal opening in the top to allow easy sharps disposal and also overfill level detection. Sharps lay on their side allowing for user observation of contents.
    Leak ProtectionThe sides and bottom of the box are a single molded piece designed not to leak. Water was added to the box to the top of the sides resulting in no leakage when kept in proper upright position.
    Sharps Access and ClosureThe box's lid is designed to close and not be reopened eliminating sharps access. Testing showed no visible access after closure if used following OSHA standards.
    StabilityThe box is designed to sit on a flat surface in an upright position. It fits easily into the top tray of a paramedic jump box and remains very stable.
    Locking MechanismThe VAULT has a one directional locking lid. It is not designed to be reopened after use.
    HandlingThe VAULT is compact and easily transported after use. It can be placed in larger secondary sharps containers if necessary for easy transport to final disposal. Although it is safe to handle by itself.
    CapacityThe VAULT was filled with liquid to determine volume of space in the box; test results indicated 3 ozs. Sharps volume varied by the size and type of sharps used. The volume indicated sufficient space for a single use sharps container.

    Study Information

    1. Sample Size used for the Test Set and the Data Provenance:

      • Sample Size: The document does not explicitly state a specific numerical sample size for most tests (e.g., "Numerous tests" for puncture resistance). For impact resistance, it refers to "The box" (singular), implying at least one box was tested. For capacity, it refers to "The vault" (singular).
      • Data Provenance: The document does not specify the country of origin or whether the tests were retrospective or prospective. It describes the testing methodologies performed by Stik Stoppers for "The VAULT."
    2. Number of Experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable. The performance criteria are based on physical characteristics and functional tests of the device, not on expert interpretation of medical images or data. Therefore, "ground truth" in the medical diagnostic sense is not relevant here.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • Not applicable. As noted above, this device relies on physical performance and functional testing rather than human interpretation requiring adjudication.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • Not applicable. This is a medical device (sharps container), not an AI-assisted diagnostic tool or an imaging device. Therefore, MRMC studies and AI assistance metrics are not relevant.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Not applicable. This is a physical medical device, not an algorithm.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • The "ground truth" for the performance criteria is based on direct observation and measurement of the device's physical properties and functional performance under defined test conditions (e.g., whether the box leaked, whether needles punctured the box, whether the lid reopened).
    7. The sample size for the training set:

      • Not applicable. This is a physical medical device, not a machine learning model requiring training data.
    8. How the ground truth for the training set was established:

      • Not applicable, as there is no training set for a physical device.