Found 3 results

510(k) Data Aggregation

    K Number
    K160443

    Validate with FDA (Live)

    Device Name
    TempoCem Clear
    Manufacturer
    Date Cleared
    2016-09-30

    (226 days)

    Product Code
    Regulation Number
    872.3275
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    TempoCem Clear is indicated for:

    • · Temporary or semipermanent luting of temporary and permanent crowns, bridges, inlays and onlays.
    • · Temporary luting of temporary veneers.
    • · Temporary or semipermanent luting of implant-borne dental prosthesis.
    Device Description

    TempoCem Clear is a transparent, dual-curing, resin-based dental cement for the temporary or semipermanent cementing of provisional resin-based composite restorations (crowns, bridges, inlays, onlays, veneers) to a tooth and for temporary or semipermanent luting to an implant abutment. The cement consists of two pastes (base and catalyst) packaged in a double-barreled plastic syringe. The pastes are automatically mixed when dispensed through the single-use mixing tips supplied with the device.

    AI/ML Overview

    The provided document is a 510(k) summary for a dental cement called TempoCem Clear. It does not contain information about a study proving the device meets specific acceptance criteria in the manner of a clinical efficacy trial with established benchmarks. Instead, it demonstrates substantial equivalence to a predicate device based on non-clinical performance data.

    Here's an analysis based on the information provided, attempting to address your questions where possible:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document doesn't explicitly state "acceptance criteria" against which the device performance is measured in a pass/fail manner. Instead, it compares the performance of TempoCem Clear to a predicate device (Telio CS Link) and references relevant ISO standards and FDA guidance. The "acceptance criteria" here are implied to be "comparable to the predicate device" or "within acceptable ranges for dental cements" as defined by the mentioned standards and guidance.

    Property (unit)Acceptance Criteria (Implied)TempoCem Clear (proposed device)Predicate Device (Telio CS Link)
    Solubility (µg/mm³)Comparable to predicate/within standard (ISO 7405)19.0 ± 1.39.1 ± 0.6
    Water sorption (µg/mm³)Comparable to predicate/within standard (ISO 7405)65.5 ± 2.077.3 ± 1.4
    Dimensional change after 7 days (%)Comparable to predicate/within standard (ISO 7405)1.0 ± 0.11.7 ± 0.1
    Gel time, self-cure (s)Comparable to predicate/within standard (ISO 7405)65165
    Setting time, self-cure (s)Comparable to predicate/within standard (ISO 7405)318216
    Bonding strength for intended useGood to satisfactory (comparable to predicate)Good to satisfactoryGood to satisfactory
    Film thickness (µm)Comparable to predicate/within standard (ISO 7405)6 ± 139 ± 3
    Heat generated during setting (peak temp, °C)Comparable to predicate/within standard (ISO 7405)43.1 ± 1.343.0 ± 0.5
    Compressive strength (MPa)Comparable to predicate/within standard (ISO 7405)78 ± 843 ± 6
    Flexural strength (MPa)Comparable to predicate/within standard (ISO 7405)5.4 ± 0.36.4 ± 0.2
    Shear bond strength (MPa)Comparable to predicate/within standard (ISO 7405)8.7 ± 1.97.8 ± 2.0
    Fluoride release over 28 days (ppm)(Unique to proposed device; predicate has no fluoride)8.0 ± 2.2No data
    BiocompatibilityDemonstrated equivalence to predicate (cytotoxicity studies)Equivalence demonstrated(Predicate previously cleared)

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not provide specific sample sizes (e.g., number of test specimens) for each of the physical and mechanical property tests. It states that "Physical and mechanical properties of TempoCem Clear were investigated and compared to the predicate device in accordance with FDA's 1998 Guidance for Industry and FDA Staff: Dental Cements - Premarket Notification (chemistry of the setting reaction, working and setting times, solubility, dimensional change, bonding strength, film thickness, heat generated during setting and biocompatibility)." This implies the tests were conducted in a laboratory setting, likely following standard test methodologies but the country of origin of the data is not specified (though the submitter information lists "DMG USA, Inc." in Massachusetts, USA). The data is by nature retrospective for the predicate device and newly generated for the proposed device.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not applicable to the type of testing described. The "ground truth" for physical and mechanical properties is established by standardized laboratory measurements rather than expert human interpretation. Biocompatibility "ground truth" is established via cytotoxic assays, not expert panels.

    4. Adjudication Method for the Test Set

    Not applicable. There is no human adjudication for these types of non-clinical, quantitative tests.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a dental cement, not an AI-assisted diagnostic device. No MRMC study was performed.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a dental cement, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    For the physical and mechanical properties, the "ground truth" is derived from direct measurements using established laboratory test methods (e.g., measuring solubility, strength, etc.) as outlined in the FDA guidance and ISO standards (e.g., ISO Standard 7405).
    For biocompatibility, the ground truth is established through cytotoxicity studies, not expert consensus or pathology in a clinical setting.

    8. The sample size for the training set

    Not applicable. This is not an AI/machine learning study, so there is no training set in that context.

    9. How the ground truth for the training set was established

    Not applicable, as there is no training set for this type of device submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K110759

    Validate with FDA (Live)

    Device Name
    TEMPOCEM
    Manufacturer
    Date Cleared
    2011-06-10

    (84 days)

    Product Code
    Regulation Number
    872.3275
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    TempoCem is a dental luting agent indicated for:

    • . temporary cementation of provisional crowns and bridges
    • cementing of semi-permanent implants .
    Device Description

    TempoCem is a temporary cement based on zinc oxide / eugenol for automatic mixing. Its low film thickness provides an exceptional fit. TempoCem combines reliable adhesion with easy and clean removal. Excess can be removed easily. TempoCem is offered in different varieties.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a dental temporary cement called TempoCem. The information focuses on regulatory approval based on substantial equivalence to predicate devices and adherence to an international standard.

    Based on the provided text, the following information regarding acceptance criteria and a study proving the device meets these criteria can be extracted or inferred:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The primary acceptance criteria for TempoCem, as stated, is that it "meets the requirements of ISO Equivalenoo in i romanto roude/eugenol and zinc oxide/non-eugenol cements - Third Edition." The text does not provide a table with specific numerical acceptance criteria from this ISO standard nor specific reported performance values for TempoCem against these criteria.

    Acceptance Criteria (from ISO Equivalenoo [likely ISO 3107: Dental zinc oxide/eugenol and zinc oxide/non-eugenol cements - Third Edition])Reported Device Performance (TempoCem)
    Specific requirements of ISO 3107 for dental cements (e.g., film thickness, compressive strength, setting time, solubility, adhesion, etc. - not detailed in current document)"Meets the requirements of ISO Equivalenoo in i romanto roude/eugenol and zinc oxide/non-eugenol cements - Third Edition." "Low film thickness provides an exceptional fit." "Combines reliable adhesion with easy and clean removal." (Specific numerical performance values are not provided in this document).

    2. Sample Size Used for the Test Set and Data Provenance:

    The document mentions that the submission is an "Abbreviated 510(k) as described in FDA's guidance document entitled 'The New 510(k) Paradigm - Alternate Approaches to Demonstrating Substantial Equivalence in Premarket Notifications.'" This typically means that new clinical data or extensive performance data might not be required if the device is substantially equivalent to a legally marketed predicate and adheres to recognized standards.

    • Sample Size for Test Set: Not specified. The document implies compliance with an ISO standard rather than a specific clinical trial with a defined test set sample size.
    • Data Provenance: Not specified. The compliance is with an "ISO" standard, which is an international standard, but the location where the tests were conducted or the origin of any data (if external to the standard's methodology) is not mentioned. It is highly likely the data is from in vitro laboratory testing to demonstrate compliance with the standard. The study is not a retrospective or prospective clinical study in the traditional sense described in the context of device performance in humans.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications:

    This information is not applicable and not provided. The device's substantial equivalence is based on meeting an ISO standard for dental cements and comparison to predicate devices, not on expert-adjudicated ground truth from a test set of patient data.

    4. Adjudication Method for the Test Set:

    This information is not applicable and not provided. As above, the evaluation is based on compliance with an ISO standard, not a human reader or expert adjudication process.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    An MRMC study was not done. The approval is for a dental cement, not an imaging or diagnostic device that would typically involve human readers.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study:

    This concept is not applicable to this device. TempoCem is a physical dental cement, not an algorithm or AI system. Its performance is intrinsic to the material properties.

    7. Type of Ground Truth Used:

    The "ground truth" here is compliance with an international standard (ISO Equivalenoo in i romanto roude/eugenol and zinc oxide/non-eugenol cements - Third Edition). This standard likely sets forth methodologies and acceptable ranges for various physical and chemical properties of dental cements.

    8. Sample Size for the Training Set:

    This information is not applicable and not provided. As TempoCem is a manufactured product and not an AI/ML algorithm, there is no "training set" in the context of data science or machine learning.

    9. How the Ground Truth for the Training Set Was Established:

    This information is not applicable and not provided. There is no ground truth for a training set in this context.

    Ask a Question

    Ask a specific question about this device

    K Number
    K970774

    Validate with FDA (Live)

    Date Cleared
    1997-06-03

    (91 days)

    Product Code
    Regulation Number
    872.3275
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    TempoCem N/E is a dental luting agent for the temporary cementation of crowns and bridges.

    Device Description

    Not Found

    AI/ML Overview

    The document provided is a 510(k) premarket notification letter from the FDA for a dental luting agent called TempoCem N/E. It does not contain any information about acceptance criteria or a study proving the device meets those criteria, as it is not a medical imaging or AI-driven device.

    Therefore, I cannot fulfill your request using the provided text. The document is about a dental cement and its regulatory approval process, not about a device that undergoes performance studies with acceptance criteria, sample sizes, expert ground truth, or MRMC studies.