510(k) Data Aggregation

    K Number
    K052677

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2005-10-12

    (14 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Synthes Universal Locking Trochanter Stabilization Plate for DHS® or LCP® DHHS is intended to treat stable and unstable intertrochanteric, subtrochanteric, pertrochanteric and basilar neck fractures when used in conjunction with the Synthes Dynamic Hip Screw (DHS®) or the LCP® Dynamic Helical Hip System (DHHS) sideplates with four or more holes.

    Device Description

    The Synthes ULTSP for DHS® and LCP DHHS fits over the sideplate of the Synthes DHS and LCP® DHHS. The ULTSP screw holes line up with the most proximal screw holes of the DHS and LCP DHHS sideplate and accept 4.5 mm cortex screws used for femoral shaft fixation. Slots accommodate both the DHS lag screw or the LCP DHHS Helix Blade and a parallel anti-rotational screw. The screw slot for the anti-rotational screw accepts a 6.5 mm cancellous bone screw or 6.5 mm, 7.0 mm or 7.3 mm cannulated screw. The proximal extension of the plate resides along the lateral side of the greater trochanter. The proximal locking holes of the ULTSP accept 3.5 mm locking screws and/or k-wires, cables, or sutures up to 2.0 mm in diameter.

    AI/ML Overview

    This document is a 510(k) summary for the Synthes Universal Locking Trochanter Stabilization Plate (ULTSP). It focuses on establishing substantial equivalence to predicate devices rather than presenting a study with specific acceptance criteria and performance data for the ULTSP itself.

    Therefore, the requested information regarding acceptance criteria, study details, sample sizes, expert involvement, and ground truth establishment cannot be extracted from the provided text. The document does not describe a performance study in the way typically expected for software or AI medical devices.

    The information provided confirms:

    • Device Name: Synthes Universal Locking Trochanter Stabilization Plate (ULTSP)
    • Intended Use: To treat stable and unstable intertrochanteric, subtrochanteric, pertrochanteric, and basilar neck fractures when used in conjunction with the Synthes Dynamic Hip Screw (DHS®) or the LCP® Dynamic Helical Hip System (DHHS) side plates with four or more holes.
    • Classification: Class II, §888.3030 - Single/multiple component metallic bone fixation appliances and accessories.
    • Predicate Devices: Synthes Trochanter Stabilization Plate (TSP) for DHS.

    No information is available regarding:

    1. A table of acceptance criteria and reported device performance.
    2. Sample sizes used for a test set or data provenance.
    3. Number of experts or their qualifications for ground truth.
    4. Adjudication method for a test set.
    5. Multi-reader multi-case (MRMC) comparative effectiveness study.
    6. Standalone performance study.
    7. Type of ground truth used.
    8. Sample size for the training set.
    9. How ground truth for the training set was established.