510(k) Data Aggregation

    K Number
    K093621

    Validate with FDA (Live)

    Date Cleared
    2010-02-23

    (92 days)

    Product Code
    Regulation Number
    892.2050
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    syngo.PET&CT Oncology is a medical diagnostic application for viewing, manipulation, 3Dvisualization and comparison of medical images from multiple imaging modalities and/or multiple time-points. The application supports functional data, such as PET or SPECT as well as anatomical datasets, such as CT or MR.

    syngo.PET&CT Oncology enables visualization of information that would otherwise have to be visually compared disjointedly. syngo.PET&CT Oncology provides analytical tools to help the user assess, and document changes in morphological or functional activity at diagnostic and therapy follow-up examinations.

    syngo.PET&CT Oncology is designed to support the oncological workflow including interpretation and evaluation of examinations, and follow up documentation of findings.

    Note: The clinician retains the ultimate responsibility for making the pertinent diagnosis based on their standard practices and visual comparison of the separate unregistered images. syngo.PET&CT Oncology is a complement to these standard procedures.

    Device Description

    The syngo.PET&CT Oncology package is a software only medical device which will be delivered on CD-ROM / DVD to be installed onto the commercially available Siemens syngo.via software platform by trained service personnel.

    syngo.PET&CT Oncology is a medical diagnostic application for viewing, manipulation, 3Dvisualization and comparison of medical images from multiple imaging modalities and/or multiple time-points. The application supports functional data, such as PFT or SPECT as well as anatomical datasets, such as CT or MR. The images can be viewed in a number of output formats including MIP and volume rendering.

    syngo.PET&CT Oncology enables visualization of information that would otherwise have to be visually compared disjointedly. syngo.PET&CT Oncology provides anaiytical tools to help the user assess, and document changes in morphological or functional activity at day nostic and therapy follow-up examinations.

    syngo.PET&CT Oncology is designed to support the oncological workflow including interpretation and evaluation of examinations, and follow up documentation of findings.

    The syngo.PET&CT Oncology package is similar to the commercially available TrueD software (K091373), syngoCT Oncology (K071310) and syngo Dual Energy software (K07303) in functionality and usage. syngo. PET&CT Oncology is intended to be run on the Siemens syngo.via software platform (K092519) either alone or with other advanced comment cleared applications.

    AI/ML Overview

    The provided document is a 510(k) Premarket Notification for the Siemens syngo.PET&CT Oncology software. It details the device's identification, description, indications for use, and a summary of the substantial equivalence determination by the FDA.

    However, the document does not contain information about specific acceptance criteria, a study that proves the device meets those criteria, or the detailed methodology of such a study (sample sizes, ground truth establishment, expert qualifications, adjudication methods, MRMC studies, or standalone performance). The document primarily focuses on establishing substantial equivalence to previously cleared devices based on intended use and technical characteristics, as is common for 510(k) submissions for image processing software.

    Therefore, I cannot provide the requested table and detailed information based solely on the provided text. The document refers to risk management and adherence to industry standards, but it does not present the results of performance studies against defined acceptance criteria.