510(k) Data Aggregation

    K Number
    K031553

    Validate with FDA (Live)

    Date Cleared
    2003-11-18

    (183 days)

    Product Code
    Regulation Number
    868.5800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Tracheostomy tubes are intended for use in providing direct tracheal access for airway management.

    Device Description

    The document describes several types of Silicone Tracheostomy Tubes: Silicone Foam Cuff Tracheostomy Tubes, Silicone Cuffless Neonatal and Pediatric Tracheostomy Tubes, Silicone Cuffless Adult Tracheostomy Tubes, and Silicone Air Cuff and Air Cuff Adjustable Neck Flange Tracheostomy Tubes. These devices are made of silicone, are radiopaque, and are white or clear in color. They include a 15mm connector and an obturator. The packaging is a PETG Tray with Tyvek Lid or a Tyvek Pouch, and they are packaged with accessories including Twill Tape and a Disconnect Wedge. Sterilization is by ETO. Labels contain product information such as name, style, size, part number, ID, OD, length, lot number, manufacturer's name, quantity, sterilization method, and expiration date. The devices comply with ASTM F 1666-95 and ASTM F 1627-95 standards.

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study for the Arcadia Medical Tracheostomy Tubes.

    Important Note: The provided text is a 510(k) Summary, which is a premarket notification to the FDA. It demonstrates substantial equivalence to a predicate device, rather than proving performance against specific acceptance criteria through a full-fledged clinical study in the way a new, high-risk device might. The "study" here is primarily a comparison to the predicate device and adherence to industry standards, along with standard manufacturing quality controls.


    Acceptance Criteria and Device Performance

    The acceptance criteria for the Arcadia Medical Tracheostomy Tubes are implicitly defined by their substantial equivalence to the Bivona Medical Technologies predicate devices and compliance with relevant ASTM standards. The "reported device performance" is essentially the device's characteristics matching or being comparable to the predicate and meeting standard specifications.

    Table of Acceptance Criteria and Reported Device Performance

    Characteristic / Acceptance CriteriaArcadia Medical Performance (Meets Acceptance Criteria)
    Common to all Tracheostomy Tubes:
    Material: SiliconeYes
    RadiopaqueYes
    Color: White (or Clear for Adjustable Neck Flange)Yes
    15mm ConnectorYes
    ObturatorYes
    Packaging: PETG Tray with Tyvek Lid (or Tyvek Pouch for Adjustable)Yes
    Accessories: Twill Tape and Disconnect WedgeYes
    Sterilization Method: ETOYes
    Label Information: Product Name, Style, Size, Part Number, ID, OD,Yes
    Length, Lot Number, Manufacturer, Quantity, Sterile-ETO, Expiration
    Adult Cuffless Tracheostomy Tubes:
    Size Range: 6.0mm, 7.0mm, 8.0mm, 9.0mm, 9.5mmYes (matches 5 sizes of predicate, predicate has 6)
    Length: 6.0=51mm, 7.0=67mm, 8.0=78mm, 9.0=91mm, 9.5=95mmYes (compared against predicate lengths)
    Neck Flange with OD/ID, Name & Model TypeYes
    Cuff Style: CufflessYes
    Complies with ASTM F 1666-95 (Adult Tracheostomy Tubes)Yes
    Pediatric Cuffless Tracheostomy Tubes:
    Size Range: 2.5mm, 3.0mm, 3.5mm, 4.0mm, 4.5mm, 5.0mm, 5.5mm (7 Sizes)Yes
    Lengths provided (e.g., 2.5=38mm to 5.5=46mm)Yes (compared against predicate lengths)
    Neck Flange with OD/ID, Name & Model TypeYes
    Wire ReinforcedYes
    Cuff Style: CufflessYes
    Complies with ASTM F 1627-95 (Pediatric Tracheostomy Tubes)Yes
    Neonatal Cuffless Tracheostomy Tubes:
    Size Range: 2.5mm, 3.0mm, 3.5mm, 4.0mm (4 Sizes)Yes
    Lengths provided (e.g., 2.5=30mm to 4.0=36mm)Yes (compared against predicate lengths)
    Neck Flange with OD/ID, Name & Model TypeYes
    Wire ReinforcedYes
    Cuff Style: CufflessYes
    Complies with ASTM F 1627-95 (Pediatric Tracheostomy Tubes)Yes
    Adult Foam Cuff Tracheostomy Tubes:
    Size Range: 6.0mm, 7.0mm, 8.0mm, 9.0mm, 9.5mmYes (matches 5 sizes of predicate, predicate has 6)
    Lengths provided (e.g., 6.0=51mm to 9.5=95mm)Yes (compared against predicate lengths)
    Neck Flange with OD/ID, Name & Model TypeYes
    Cuff Style: Foam Cuff with Pilot Port and attached plugYes
    Complies with ASTM F 1666-95 (Adult Tracheostomy Tubes)Yes
    Adult Air Cuff Tracheostomy Tubes:
    Size Range: 6.0mm, 7.0mm, 8.0mm, 9.0mm, 9.5mmYes (matches 5 sizes of predicate, predicate has 6)
    Lengths provided (e.g., 6.0=51mm to 9.5=95mm)Yes (compared against predicate lengths)
    Neck Flange with OD/ID, Name & Model TypeYes
    Cuff Style: Air Cuff with Pilot Balloon, Inflation Valve, InflationYes
    Line
    Complies with ASTM F 1666-95 (Adult Tracheostomy Tubes)Yes
    Adult Air Cuff Adjustable Neck Flange Tracheostomy Tubes:
    Size Range: 6.0mm, 7.0mm, 8.0mm, 9.0mm (4 Sizes)Yes
    Usable Length: 6.0=110mm, 7.0=120mm, 8.0=130mm, 9.0=140mmYes
    Adjustable Neck Flange with OD/ID, Name & Model TypeYes
    Wire ReinforcedYes
    Color: ClearYes
    Cuff Style: Air Cuff with Pilot Balloon, Inflation Valve, InflationYes
    Line
    Above the Cuff Access Port for Suctioning and VocalizationYes (Predicate "Not Available on this Model")
    Introducer/ObturatorYes
    Complies with ASTM F 1666-95 (Adult Tracheostomy Tubes)Yes

    Study Details to Prove Acceptance Criteria

    The provided text is a 510(k) summary, which focuses on demonstrating "substantial equivalence" of the new device to a predicate device already on the market. It does not describe a clinical study in the traditional sense with a "test set" of patients, ground truth experts, or an AI algorithm. Instead, the "study" is a comparison of technical characteristics and compliance with recognized standards.

    1. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective):

      • Test Set Sample Size: Not applicable in the context of a 510(k) substantial equivalence comparison based on technical characteristics. The "test" is a comparison to the predicate device's specifications and ASTM standards.
      • Data Provenance: The data is a comparison of specifications of the Arcadia Medical device against the Bivona Medical Technologies predicate device and relevant ASTM standards. This is a technical comparison, not patient data. It is inherently "prospective" in the sense that the new device's specifications are established. Country of origin for data is not explicitly stated beyond Arcadia Medical being in Schaumburg, IL, USA.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Number of Experts: Not applicable. Ground truth for a device's technical specifications is established through engineering design, testing, and compliance with industry standards, not typically by expert consensus in the way clinical images would be. The "experts" are the engineers and quality assurance personnel at Arcadia Medical and the standards bodies (ASTM) who defined the specifications.
    3. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

      • Adjudication Method: Not applicable. This is a comparison of technical specifications to a predicate device and industry standards, not a judgment of clinical data.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • MRMC Study: No, an MRMC study was not done. This device is a physical medical device (tracheostomy tube), not an AI algorithm for diagnostic imaging.
    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

      • Standalone Study: No, this device is a physical medical device, not an AI algorithm.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • Type of Ground Truth: The "ground truth" for this submission are the established technical specifications of the predicate device (Bivona Medical Technologies tracheostomy tubes) and the requirements outlined in relevant ASTM International standards (ASTM F 1666-95 for Adult Tracheostomy Tubes and ASTM F 1627-95 for Pediatric Tracheostomy Tubes). This is a specification-based ground truth or standard compliance ground truth.
    7. The sample size for the training set:

      • Training Set Sample Size: Not applicable. This is not an AI algorithm that requires a training set. The development of the device would involve engineering design, prototyping, and testing, but these are not referred to as "training sets" in this context.
    8. How the ground truth for the training set was established:

      • Ground Truth for Training Set: Not applicable, as there is no "training set" for physical device development in the AI sense. The design and manufacturing processes are guided by the "ground truth" of the predicate device's successful performance and adherence to established industry standards for safety and efficacy.