510(k) Data Aggregation

    K Number
    K042702

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2004-11-23

    (54 days)

    Product Code
    Regulation Number
    888.3070
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Silhouette™ Spinal System is intended for posterior, noncervical pedicle fixation for the following indications: degenerative disc disease (DDD) (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e. fracture and dislocation); spinal stenosis; deformities (i.e. scoliosis, kyphosis and/or lordosis); tumor; pseudoarthrosis; and failed previous fusion. Pedicle screw fixation is limited to skeletally mature patients.

    When used as a hook and sacral screw system, the Silhouette Spinal Fixation System is intended for use in the treatment of degenerative disc disease (as defined by chronic back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), idiopathic scoliosis, spondylolisthesis, kyphotic or lordotic deformity of the spine, loss of stability due to turnors, spinal stenosis, vertebral fracture or dislocation, pseudoarthrosis, and previous failed spinal fusion. When used for this indication, screws of the Silhouette™ Spinal Fixation System are intended for sacral iliac attachment only. Hook and transverse connectors of the system are intended for posterior thoracic and/or lumbar use only. As a whole, the levels of use for the hook and sacral screw fixation of this system are T1 to the sacrum.

    Device Description

    The Zimmer Spine Silhouette Spinal Fixation System is a temporary implant system used to correct spinal deformity and facilitate the biological process of spinal fusion. This system is intended for the noncervical posterior use in the thoracic, lumbar and sacral areas of the spine. Implants of this system consist of hooks and/or screws connected to rods and are intended to be removed after solid fusion has occurred. The system includes polyaxial screws of varying diameters and lengths, fixed screws of varying diameters and lengths, rods in varving lengths, hooks in varying designs, fixed and adjustable transverse connectors. All implant components are top loading and top tightening. All the implants in this system are manufactured from titanium alloy (Ti-6A1-4V) conforming to ASTM F-136.

    AI/ML Overview

    The provided text is a 510(k) summary for a spinal fixation system, not a study evaluating a medical device based on acceptance criteria. Therefore, most of the requested information cannot be extracted from this document, as it pertains to a clinical study or performance evaluation with specific metrics.

    Here's a breakdown of why and what little information can be gleaned:

    Reasoning for inability to answer most questions:

    • Type of Document: This is a 510(k) summary, which is a premarket notification for a medical device. Its primary purpose is to demonstrate substantial equivalence to a legally marketed predicate device, rather than to present the results of a detailed performance study against pre-defined acceptance criteria for a novel AI or diagnostic device.
    • Focus on Equivalence: The document explicitly states "There are no technological differences between the Silhouette Spinal Fixation System and the previously cleared Silhouette Spinal Fixation System" and "The Silhouette Spinal System is substantially equivalent to the original Silhouette Spinal System based on materials, design, function and the supporting information included in the Class III Certification and Summary." This means the "study" is a comparison to a predicate, not a performance study against specific criteria for a new device.
    • Device Type: The device is a "Spinal Fixation System," which is a physical implant (hooks, screws, rods). The concept of "acceptance criteria" and "device performance" in this context refers to mechanical properties (e.g., strength, fatigue, biocompatibility) rather than diagnostic accuracy metrics (e.g., sensitivity, specificity, AUC) typically associated with AI or imaging devices. This document does not detail those mechanical tests or their results.
    • Missing Study Details: There is no mention of "test sets," "ground truth," "experts," "adjudication methods," "MRMC studies," "standalone performance," or "training sets," as these are all relevant to the evaluation of AI/diagnostic algorithms, not material equivalence for a physical implant.

    Information that can be extracted (with caveats):

    1. A table of acceptance criteria and the reported device performance:

      • Cannot be provided directly. The document does not define specific "acceptance criteria" in terms of performance metrics (like sensitivity, specificity, accuracy). Instead, the overall acceptance criterion for 510(k) clearance is "substantial equivalence" to a predicate device.
      • Reported Device Performance: The primary "performance" reported is its substantial equivalence to the predicate. The document states:
        • "There are no technological differences between the Silhouette Spinal Fixation System and the previously cleared Silhouette Spinal Fixation System."
        • "The Silhouette Spinal System is substantially equivalent to the original Silhouette Spinal System based on materials, design, function and the supporting information included in the Class III Certification and Summary."
        • This implies that the device performs the same as the predicate. The specific mechanical performance (e.g., strength, fatigue life) that would underpin this substantial equivalence is not detailed in this summary.
    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

      • Not applicable. There is no "test set" in the context of an algorithm or diagnostic study. The "test" for this device involved demonstrating equivalence in materials, design, and function to a predicate device, likely through engineering analysis and potentially mechanical testing, not a dataset of patients or images.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):

      • Not applicable. No ground truth was established for a "test set" as this is not a diagnostic device.
    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • Not applicable. No test set or adjudication method described.
    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • Not applicable. This is a physical implant, not an AI or diagnostic tool.
    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Not applicable. This is a physical implant, not an algorithm.
    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

      • Not applicable. No ground truth in the context of an AI/diagnostic study. The "ground truth" for this 510(k) application is essentially adherence to established standards for spinal implants and demonstrating equivalence to a previously cleared device.
    8. The sample size for the training set:

      • Not applicable. No training set for an algorithm.
    9. How the ground truth for the training set was established:

      • Not applicable. No training set described.

    In summary, the provided document is a regulatory filing for a physical medical device (spinal implant) demonstrating substantial equivalence to a predicate device, rather than a clinical or performance study of an AI-powered or diagnostic device. Therefore, the specific questions regarding acceptance criteria, test sets, ground truth, and expert evaluation are not relevant to this document's content.

    Ask a Question

    Ask a specific question about this device

    K Number
    K993067

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1999-11-16

    (64 days)

    Product Code
    Regulation Number
    888.3050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    When used as a pedicle screw fixation system in skeletally mature patients, the Silhouette™ Spinal Fixation System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, spinal tumor, and failed previous fusion (pseudarthrosis).

    In addition, when used as a pedicle screw fixation system, the Silhouette™ Spinal Fixation System is indicated for use in patients:

    • having severe spondylolisthesis (Grade 3 and 4) at the L5-S1 joint
    • who are receiving fusions with autogenous graft only
    • who are having the device fixed or attached to the lumbar or sacral spine, and
    • who are having the device removed after the development of a solid fusion mass

    When used as a hook and sacral screw system, the Silhouette™ Spinal Fixation System is intended for use in the treatment of degenerative disc disease (as defined by chronic back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), idiopathic scoliosis, spondylolisthesis, kyphotic or lordotic deformity of the spine, loss of stability due to tumors, spinal stenosis, vertebral fracture or dislocation, pseudoarthrosis, and previous failed spinal fusion. When used for this indication, screws of the Silhouette™ Spinal Fixation System are intended for sacral iliac attachment only. Hook and transverse connectors of the system are intended for posterior thoracic and/or lumbar use only. As a whole, the levels of use for hook and sacral screw fixation of this system are T1 to the sacrum.

    Device Description

    The Silhouette™ Spinal Fixation System is a temporary implant system used to correct spinal deformity and to facilitate the biological process of spinal fusion. This system is intended for posterior use in the thoracic, lumbar, and sacral areas of the spine. Implants in this system consist of hooks and/or screws connected to rods that are intended to be removed after solid fusion has occurred. The system includes polyaxial screws of varving diameters and lengths, fixed screws of varying diameters and lengths, rods in varying lengths, hooks in varying designs, and transverse connectors in fixed and adjustable widths. All implant components are top loading and top tightening. The implants in this system are manufactured from titanium alloy (Ti-6A1-4V) that conforms to ASTM F-136.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the Sulzer Spine-Tech Silhouette™ Spinal Fixation System, based on the provided document:

    Acceptance Criteria and Device Performance

    1. Table of Acceptance Criteria and Reported Device Performance

    ModificationTest PerformedAcceptance CriteriaTest Results
    Addition of Adjustable Transverse ConnectorFatigue Testing of Silhouette™ Spinal Fixation System/adjustable transverse connector construct per ASTM Provisional Standard PS 5-94, Test Method for Static and Dynamic Spinal Implant Assembly in a Corpectomy ModelNo Failures 156 N run-out load 5,000,000 cyclesPassed

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the sample size for the test set. It mentions "Fatigue Testing of Silhouette™ Spinal Fixation System/adjustable transverse connector construct." The data provenance is not specified beyond being generated by Sulzer Spine-Tech for regulatory submission. It is a non-clinical, in-vitro test.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not applicable. The study is a non-clinical, in-vitro device performance test against a predefined engineering standard (ASTM Provisional Standard PS 5-94), not a clinical study involving expert interpretation of data or patient outcomes. Therefore, there's no "ground truth" in the sense of expert consensus on clinical findings.

    4. Adjudication Method for the Test Set

    This is not applicable. Adjudication methods are typically relevant for clinical studies where there may be disagreements among human reviewers. This was a physical performance test.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study was not done. This document describes non-clinical engineering performance testing of a spinal fixation system.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Yes, in a sense, a "standalone" test was performed. The device, specifically the adjustable transverse connector and the system construct, was subjected to a standalone physical performance test without human involvement in its operation or interpretation during the test itself. The test was to evaluate the physical properties of the device against an established standard.

    7. The Type of Ground Truth Used

    The ground truth used was based on an established engineering standard: ASTM Provisional Standard PS 5-94, Test Method for Static and Dynamic Spinal Implant Assembly in a Corpectomy Model. The acceptance criteria (no failures, 156 N run-out load, 5,000,000 cycles) are derived directly from this standard.

    8. The Sample Size for the Training Set

    This information is not applicable. This document describes performance testing of a physical medical device, not an AI/ML algorithm that would require a training set.

    9. How the Ground Truth for the Training Set Was Established

    This information is not applicable, as there is no training set for an AI/ML algorithm.