510(k) Data Aggregation

    K Number
    K250540

    Validate with FDA (Live)

    Device Name
    SABER-C System
    Manufacturer
    Date Cleared
    2025-08-08

    (165 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Elevation Spine Saber-C System is a cervical interbody fusion device intended for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine (C2-T1) and is for use in one or two adjacent spinal levels. DDD is defined as discogenic pain with degeneration of the disc confirmed by history and radiographic studies. These patients should be skeletally mature and have had at least six (6) weeks of non-operative treatment. The SABER-C Spacer is to be filled with autograft bone and/or allogenic bone graft composed of cancellous and/or corticocancellous bone.

    The SABER-C Spacer is intended to be used with supplemental fixation, such as anterior cervical plates or posterior cervical screw fixation. When the SABER-C Spacer is used with the SABER-C Anterior Cervical Plate and screws, the plate-spacer-screw assembly can be used as a stand-alone device with the SABER-C Anterior Cervical Plate acting as the supplemental fixation. When the SABER-C Spacer is used with the SABER-C Anterior Cervical Plate and spikes, the plate-spacer-spike assembly should be used with additional supplemental fixation such as posterior cervical screw fixation.

    The SABER-C Anterior Cervical Plate, when used without the spacer component and with screws, is intended for anterior screw fixation to the cervical spine (C2-C7) for the following indications: degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumors, deformity (defined as kyphosis, lordosis, or scoliosis), pseudoarthrosis, failed previous fusion, spondylolisthesis, and spinal stenosis. The Anterior Cervical Plate is not to be used with spikes when used without the Spacer component.

    Device Description

    The SABER-C System is a cervical interbody fusion device used to provide structural stability in skeletally mature individuals following discectomy. The SABER-C System is inserted through an anterior cervical approach and is available in various geometric and material options to fit the clinical needs of the patient. The SABER-C System Anterior Cervical Plate is an anterior cervical fixation device this is available in various geometric and fixation options and can be used with various types of interbody spacers.
    The previously cleared SABER-C interbody devices are offered manufactured from titanium alloy per ASTM F136 or titanium-coated radiolucent polyether ether ketone (PEEK), with titanium alloy or tantalum markers, as specified in ASTM F2026, ASTM F136, ASTM F1295, and ASTM F560. The SABER-C Anterior Cervical Plate and two fixation options, spikes or screws, are manufactured from titanium alloy, as specified in ASTM F136 and ASTM F1295. The plate is not to be used with spikes when used without the Spacer component.
    The subject submission seeks to expand size offerings and gain clearance for expanded indications and minor design modifications to the previously cleared devices.

    AI/ML Overview

    The provided text is a 510(k) clearance letter for the SABER-C System, an intervertebral body fusion device. It details the regulatory clearance, indications for use, device description, and a brief summary of performance testing.

    However, the document does not contain information related to a study proving the device meets acceptance criteria specific to an AI/ML algorithm, nor does it specify any AI/ML components within the SABER-C System. The performance testing listed is entirely mechanical/physical bench testing for a physical implant (Axial Screw Pullout, Insertion Torque, plate pushoff), which is standard for orthopedic devices.

    Therefore, it is not possible to complete the requested table and answer questions about AI/ML acceptance criteria, study design, sample sizes for AI, expert involvement for AI ground truth, MRMC studies, or standalone algorithm performance based on the provided text. The document is for a traditional medical device, not a software as a medical device (SaMD) or an AI-enabled device.

    To address the prompt directly based on the provided text, the answer is that the document does not contain the information requested, as the device is a physical implant and not an AI/ML enabled medical device.

    Summary of missing information directly related to AI/ML acceptance criteria and study:

    • No AI/ML Component: The document describes a physical interbody fusion device and its associated plates and screws. There is no mention of any AI or machine learning functionality.
    • Acceptance Criteria for AI/ML: Since there's no AI component, there are no acceptance criteria related to AI performance metrics (e.g., accuracy, sensitivity, specificity, AUC).
    • Study Proving AI Compliance: There is no study described that would evaluate AI performance. The performance testing mentioned is purely mechanical (bench testing).
    • Sample Size (AI): Not applicable, as there's no AI component.
    • Data Provenance (AI): Not applicable.
    • Experts for Ground Truth (AI): Not applicable.
    • Adjudication Method (AI): Not applicable.
    • MRMC Study: Not applicable.
    • Standalone Performance (AI): Not applicable.
    • Type of Ground Truth (AI): Not applicable.
    • Training Set Sample Size (AI): Not applicable.
    • Training Set Ground Truth (AI): Not applicable.

    If the prompt assumed an AI/ML component was present and requested how one would describe these aspects for a hypothetical AI/ML device in a similar FDA clearance, I would construct a general example. However, as the instruction is to describe "the study that proves the device meets the acceptance criteria" based on the input, and the input clearly does not describe an AI/ML device, the direct answer is that the information is not present.