510(k) Data Aggregation

    K Number
    K182909

    Validate with FDA (Live)

    Date Cleared
    2018-11-21

    (35 days)

    Product Code
    Regulation Number
    876.4300
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Roth Net Retriever Product Line is intended to be used to retrieve excised polyps, tissue samples, foreign bodies and calculi during flexible and rigid endoscopy procedures.

    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) clearance letter from the FDA for the Roth Net Retriever Product Line. It is a regulatory document and does not contain any information about acceptance criteria, device performance studies, or AI-related metrics (such as effect size of human readers with/without AI assistance).

    Therefore, I cannot fulfill your request for the following sections based on the provided text:

    • A table of acceptance criteria and the reported device performance
    • Sample sized used for the test set and the data provenance
    • Number of experts used to establish the ground truth for the test set and the qualifications of those experts
    • Adjudication method for the test set
    • If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
    • If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
    • The type of ground truth used
    • The sample size for the training set
    • How the ground truth for the training set was established

    The document primarily focuses on:

    • Confirming the substantial equivalence of the Roth Net Retriever Product Line to legally marketed predicate devices.
    • Outlining regulatory requirements the manufacturer must adhere to.
    • Stating the intended use of the device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K122462

    Validate with FDA (Live)

    Date Cleared
    2012-09-11

    (29 days)

    Product Code
    Regulation Number
    876.4300
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Roth Net® retriever product line is intended to be used to retrieve excised polyps, tissue samples, foreign bodies and calculi during flexible and rigid endoscopy procedures.

    Device Description

    The Roth Net retriever product line is intended to be used to retrieve excised polyps, tissue samples, foreign bodies and calculi during flexible and rigid endoscopy procedures. The device is marketed in both sterile and non-sterile versions. The fundamental design and technology of the Roth Net® retriever are the same as the predicate Polyp Snare Net originally submitted under K926104 with the exception of the changes listed below. The device consists of a proximal handle with a finger ring that controls the deployment of the fabric mesh basket (a wire snare with a fabric net attached). The snare/net is connected to a drive wire, which is then connected to the handle. The drive wire is encompassed within a sheath that makes up the catheter.

    AI/ML Overview

    The Roth Net® retriever product line, subject of K122462, is intended for retrieving excised polyps, tissue samples, foreign bodies, and calculi during flexible and rigid endoscopy procedures. The submission details several modifications from the predicate device (Polyp Snare Net, K926104). The studies conducted focus on verifying that these modifications do not adversely affect the device's performance, safety, or effectiveness, and that the device remains substantially equivalent to its predicate.

    1. Table of Acceptance Criteria and Reported Device Performance

    Device ModificationReason for ModificationAcceptance CriteriaVerification Results
    Changes for Clinical Ease of Use
    Change in snare shape (round to octagonal) and snare loop wire shape (braided to flat)To better allow the loop to maintain its shape and allow for greater capacity.1. Force required to deploy and retract shall be ≤ 3.25 lbs. 2. Net can be fully retracted without any parts left outside of the sheath. 3. Net can be fully deployed without exposing the proximal end of the connector.PASS
    Change in the mesh size of the netTo improve visibility when capturing multiple polyp fragments.1. Must maintain ability to grasp and retrieve simulated polyps and foreign bodies. 2. Net is capable of securing material that measures 2cm x 1.5cm x 2.5cm. 3. Visualization of pouch and its contents are not obstructed.PASS
    Dimensional Changes: Increased length and diameter of device sheath/catheterAllow use of subject-device with various endoscopes.1. Length shall be 138.00 ± 2.5 inches (350.5 ± 6.35 cm). 2. Visible plastic deformation due to compression must not occur in an insertion column length of 1.5 in (3.8 cm) through the accessory channel of the endoscope. 3. Device shall capture simulated food bolus, foreign bodies or polyps while maintaining structural integrity. 4. Insertion force of less than or equal to 2.5 lbs.PASS
    Dimensional Changes: Net size changed to largest size: 3 cm (l) x 4 cm (w)To allow device to be used with endoscopes with larger channels.1. Max deployment/retraction force shall be ≤ 3.25 lbs. 2. The length of the fully deployed net shall be 2.59 - 3.29 inches (6.6 – 8.4 cm). 3. The width of the fully deployed net shall be 1.41 – 2.10 inches (3.6 – 5.3 cm).PASS
    Changes for Increased Manufacturing Efficiency
    A chamfer melt was added on the inside of the catheterTo maintain the smooth transition of the snare/net into the catheter when the snare/net is retracted.Max deployment force shall be ≤ 3.25 lbs. Max retraction force shall be ≤ 3.25 lbs.PASS
    Change in the mesh configuration to add bidirectional meshIncreased manufacturability.1. Grasp the objects and held securely in the net. 2. Beads are captured and controlled.PASS
    Change in the length of the wire loop ends of the snare loop assembly and flat wireTo facilitate the change from a crimp to a resistance welding connection.Tensile pull must be ≥ 12 lbs (Test connection between drive cable to wire form of the snare loop).PASS
    Addition of a mesh net tail on the distal and proximal sides of the netEliminate the need for thread as an anchor to prevent net cinching.1. Nets shall not cinch. 2. Proximal and distal anchors shall remain intact.PASS
    Material Change
    Catheter material modified from TFE to PECost Reduction without reducing performance.Material shall show no reactivity in test subjects.PASS
    Appearance Change
    Change handle color from white to silverAdd new color to distinguish between standard and platinum models.No risks were identified in relation to this modification. No performance data were required because a change in color of the handle does not affect performance of the subject device.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the sample sizes for each specific test, nor does it detail the provenance of the data (e.g., country of origin, retrospective/prospective). However, for the tensile strength testing, it is mentioned that the "Test connection between drive cable to wire form of the snare loop" was performed on 30 devices. For other functional tests, terms like "simulated polyps and foreign bodies," "variety of items," and "test subjects" are used, implying in-vitro or bench testing rather than human clinical data. The studies are described as "verification and validation testing" and "design verification tests," which are typically internal development and testing activities.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    The document does not mention the use of experts to establish a "ground truth" for the test set in the context of clinical interpretation or diagnosis. The testing performed is focused on the physical and functional performance of the device's modifications against engineering specifications and simulated use scenarios. Therefore, the concept of qualified experts establishing a ground truth in an interpretive sense (like radiologists for imaging) is not applicable here. The "ground truth" for these tests would be the established engineering specifications and successful completion of the functional tasks.

    4. Adjudication Method for the Test Set

    No adjudication method (e.g., 2+1, 3+1) is mentioned or appears applicable, as the tests described are objective measurements of physical performance and functional capabilities against predefined specifications (e.g., force measurements, dimensions, grasping ability). These are not subjective interpretations requiring adjudicators.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and Effect Size

    No MRMC comparative effectiveness study was conducted or mentioned. This type of study (comparing human readers with and without AI assistance) is not relevant for a physical medical device like the Roth Net® retriever, which is a tool for retrieval during endoscopy, not an AI-powered diagnostic device.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study Was Done

    This question is not applicable. The Roth Net® retriever is a physical medical device that is used by a human during an endoscopy procedure; it does not involve any algorithms or standalone AI performance.

    7. The Type of Ground Truth Used

    The "ground truth" used for these studies is based on:

    • Engineering Specifications: Predefined numerical values for dimensions, forces, and material properties.
    • Functional Performance Criteria: The ability of the device to successfully perform its intended functions in simulated environments (e.g., grasp simulated polyps, retract fully, maintain structural integrity).
    • Biocompatibility Standards: Compliance with ISO 10993 standards for material safety, where "no reactivity in test subjects" serves as the ground truth for biocompatibility.

    8. The Sample Size for the Training Set

    No training set is applicable. This device is not an AI/ML-based device that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for this device.