    Sunrise powered wheelchairs empower physically challenged persons by providing a means of mobility.

    Device Description

    The Quickie P190 R (or S525) is a medium duty, conventional, rear wheel drive, and rigid frame power wheelchair. The Quickie P190R Power Wheelchair consists of typical components found on most wheelchairs, such as push handles, armrests, backrest, seat frame, cushion, footrest and casters. Accessories that may be added after market include items such as positioning belts, backpacks, seat pouches, oxygen tank holders, IV poles, etc. As a motorized wheelchair, it also controller, a joystick, a motor, brakes, a drive wheel and 2 batteries. Like most power wheelchairs, the joystick is the user interface. It transfers intentions to command the chair. When the control is activated, or moved out of the center position, the motor brake is energized and released, allowing the chair to move in the direction of the activation. When the activation device (joystick or afternate input device) is released, the chair slows to a stop and the motor brake is automatically re-engaged. These dynamic "on command" brakes allow the user to stop by letting go of the activation device. If the chair loses power, the motor brake is automatically engaged and the chair comes to a stop. To prevent the rider from becoming stranded, the chair may be pushed. The chair incorporates a "free wheel" device motor lock disengagement option. This option allows the drive train to be manually disengaged, enabling the chair to be more easily pushed by an assistant. It should be noted that the chair would not have electronic brakes when in the "free wheel" mode. However, the manual wheel locks (also optional) will still function if engaged.

    AI/ML Overview

    This 510(k) premarket notification for the Sunrise Medical S-525 Power Wheelchair is primarily focused on demonstrating substantial equivalence to predicate devices through a comparison of technological characteristics and adherence to recognized performance standards. Itdoes not describe a study involving an AI/Machine Learning device or a diagnostic/screening medical device in the way typically expected by your request. Therefore, many of the requested categories (e.g., sample size for test set, number of experts, MRMC studies, standalone performance, training set details) are not applicable to the information provided in this document.

    However, I will extract and present the information available that aligns with your request, interpreting "acceptance criteria" as the standards the device was tested against and "device performance" as its successful adherence to those standards.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Standard Tested Against)Reported Device Performance
    ISO 7176 Wheelchair Standards:Device tested to these standards
    - Static StabilityImplied successful performance
    - Dynamic StabilityImplied successful performance
    - Effectiveness of BrakesImplied successful performance
    - Energy consumptionImplied successful performance
    - Overall DimensionsImplied successful performance
    - Maximum SpeedImplied successful performance
    - Acceleration and retardationImplied successful performance
    - Static ImpactImplied successful performance
    - Fatigue StrengthImplied successful performance
    - Climatic TestImplied successful performance
    - Obstacle Climbing AbilityImplied successful performance
    - Testing of Power and Control SystemImplied successful performance
    - EMC TestingImplied successful performance
    ANSI/RESNA Wheelchair Standards:Device tested to these standards
    - Static StabilityImplied successful performance
    - Dynamic StabilityImplied successful performance
    - Effectiveness of BrakesImplied successful performance
    - Energy consumptionImplied successful performance
    - Overall DimensionsImplied successful performance
    - Maximum SpeedImplied successful performance
    - Acceleration and retardationImplied successful performance
    - Static ImpactImplied successful performance
    - Fatigue StrengthImplied successful performance
    - Climatic TestImplied successful performance
    - Obstacle Climbing AbilityImplied successful performance
    - Testing of Power and Control SystemImplied successful performance
    - EMC TestingImplied successful performance
    Proposed Addition to ANSI/RESNA W/C 14 Electromagnetic Compatibility Requirements for Powered Wheelchairs and Motorized Scooters Version 1.5 Dated 1/11/94Device tested to this proposed standard
    ISO EMC Draft Standard 7176-14 Rifled Draft ISO EMC Group Proposal Electromagnetic Compatibility Addition Dated 4/3/95 Regarding Electromagnetic Compatibility Requirements for Powered Wheelchairs and Motorized ScootersDevice tested to this proposed standard

    2. Sample Size Used for the Test Set and the Data Provenance

    • Sample Size: This document does not specify a separate "test set" in the context of device performance data generation for a diagnostic/screening algorithm. The testing described refers to the physical device itself. It's implied that at least one S-525 Power Wheelchair was tested against the listed standards.
    • Data Provenance: The testing was conducted internally by Sunrise Medical. The country of origin of the data is the United States, as Sunrise Medical is a US-based company, and the submission is to the FDA. The testing conducted is for prospective validation of the device's adherence to safety and performance standards.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts

    • This section is not applicable. The "ground truth" for a physical product like a power wheelchair is defined by its engineering specifications and its adherence to the published performance standards. There is no mention of human experts establishing ground truth for a diagnostic output.

    4. Adjudication Method for the Test Set

    • This section is not applicable. Adjudication methods like 2+1 or 3+1 are used for human interpretation of data, typically in diagnostic studies. Here, the device's performance is objectively measured against technical standards.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • This section is not applicable. This document describes a physical medical device (power wheelchair), not an AI/ML-driven diagnostic tool that would involve human readers.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    • This section is not applicable. The S-525 Power Wheelchair is a physical product operated by a user, not an algorithm. The performance described is of the complete physical device.

    7. The type of ground truth used

    • The ground truth for the S-525 Power Wheelchair's performance is established by conformance to internationally recognized and national engineering/performance standards (ISO 7176 and ANSI/RESNA). This is an objective, measurable "ground truth" based on predefined specifications and safety thresholds. It is not expert consensus, pathology, or outcomes data in the context of a diagnostic test.

    8. The sample size for the training set

    • This section is not applicable. This device is a physical product, not an AI/ML system that requires a "training set."

    9. How the ground truth for the training set was established

    • This section is not applicable, as there is no training set for this type of device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K963382

    Validate with FDA (Live)

    Date Cleared
    1997-04-28

    (244 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Quickie Powered Wheelchairs empower physically challenged persons by providing a means of mobility.

    Device Description

    Quickie powered wheelchairs consist of typical features found on any wheelchair, such as push handles, adjustable armrests, backrest, seat frame and cushion, footrests, and casters. Because these are motorized wheelchairs, they also consist of joy stick controller, motors, brakes, batteries and drive wheels.

    AI/ML Overview

    The provided text is a Summary of Safety and Effectiveness for the Quickie Powered Wheelchair with Penny and Giles Controller, a medical device submission. It describes the device, its intended use, and compares it to predicate devices. However, the document does not contain the information requested in your prompt regarding acceptance criteria and a study proving the device meets those criteria, specifically:

    • Table of acceptance criteria and reported device performance: This is absent. The document only states that testing "demonstrate that the wheelchair performs as the predicate device" and "according to specification," but no specific criteria or quantified performance metrics are provided.
    • Sample size and data provenance for the test set: Not mentioned for any testing.
    • Number of experts and their qualifications for ground truth: Not applicable, as this is hardware testing, not an AI or diagnostic study requiring expert consensus.
    • Adjudication method: Not applicable.
    • Multi-reader multi-case (MRMC) comparative effectiveness study: Not conducted, as this is a physical device and controller modification, not a diagnostic imaging or AI-assisted interpretation system.
    • Standalone (algorithm only) performance: Not applicable, as it's a physical controller; its performance is always "in-the-loop" with the wheelchair.
    • Type of ground truth used: For non-clinical testing, the "ground truth" would be engineering specifications and safety standards, but these are not explicitly detailed.
    • Sample size for the training set: Not applicable, as this is hardware testing, not a machine learning model.
    • How ground truth for the training set was established: Not applicable.

    The document primarily focuses on demonstrating substantial equivalence to existing predicate devices through non-clinical testing of programmable parameters and electromagnetic compatibility (EMI). The core assertion is that the new P&G controller does not change the core wheelchair specifications and performs comparably to the previous Dynamics controller, which is already on the market.

    Specific findings from the document related to testing:

    • Non-clinical testing: Performed on all programmable parameters, including:
      • Maximum and minimum forward and reverse speeds
      • Maximum and minimum turn speeds
      • Maximum and minimum acceleration and deceleration
      • Maximum and minimum turn acceleration and deceleration
    • Comparative testing: Regarding speed, acceleration, and brake distance, results "demonstrate that the wheelchair performs as the predicate device with the Dynamics controller."
    • Electromagnetic compatibility testing: Performed, and results "demonstrate that the wheelchairs pass the 20 V/m EMI test."
    • Software validation information: Includes requirements, design, development, verification, validation, hazard analysis, and mitigation associated with controller safety.

    In summary, the document states that the device meets "specifications" and performs "as the predicate device," but it does not provide the quantitative acceptance criteria or detailed study results that your prompt requests. The nature of this submission (a modification of a physical device's controller) does not lend itself to many of the AI-specific questions in your prompt.