510(k) Data Aggregation

    K Number
    K253952

    Validate with FDA (Live)

    Date Cleared
    2026-04-07

    (118 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K254206

    Validate with FDA (Live)

    Date Cleared
    2026-03-27

    (88 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    It is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The product is intended only carry one person and used as a means of transportation for the disabled, the sick and the infirm.

    The power wheelchair is classified as class A and the maximum occupant mass is 150kg.

    The power wheelchair is a battery powered four wheeled vehicle.

    It consists one Lithium battery with an off-board battery charger, frame, controller, motors, seat, back cushion, control system, armrest, two rear wheels, two casters(front wheels), foot pedal, anti-tip devices.

    The power wheelchair can easily fold and unfold for transportation or storage.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251159

    Validate with FDA (Live)

    Device Name
    Power wheelchair
    Date Cleared
    2025-12-22

    (251 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    It is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    This product consists of frame, wheels, seat, armrest, backrest, headrest, battery, motor and controller with a lightweight and compact design. The whole wheelchair can be folded and it can be easily carried or rolled after folding. The backrest, headrest and armrest can be adjustable. Users can drive the wheelchair by themselves through the control device.

    The wheelchair uses lead-acid batteries as its power source. The controller controls the drive left/right motor to realize the wheelchair forward, backward and turn functions.

    The frame of the device is steel and aluminum. The front wheels are driven wheels suitable for rotation, acceleration, retrograde and other actions of the wheelchair. The front wheels movement will be achieved by thrust generated from the rear wheels. The rear wheels are driving wheels to control the speed and direction. The wheels are Solid PU tires.

    When in use, the operator drives the motor of the rear wheel by operating the joystick to achieve the rear wheels movement.

    The DC brushless motor and brake system are fixed on the rear wheels.

    The max loading of the device is 135KG. Only for one person sit.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250729

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-07-02

    (113 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    It is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The subject device, Power Wheelchair, mainly powered by battery, motivated by DC motor, driven by user controlling joystick controller and adjusting speed. Products for adult use.

    The Power Wheelchair is a battery powered four wheeled vehicle. It consists Li-ion battery with an off-board battery charger, Push handle, Seat, Back support, Joystick controller, Control panel (including: Speed light, ON/OFF button, Horn, Joystick, Accelerated button, Deceleration button), Arm supports, Anti-tip wheel, Front wheel, Rear wheels.

    The operation of the Controller: Use the On/Off button to turn on or turn off the power, The main function of the Joystick is to control the speed and direction of the wheelchair, the Joystick can control the wheelchair to travel in any direction, the operation of the Joystick movement will determine the wheelchair in that direction speed of movement. The farther the Joystick is moving from the center, the faster the wheelchair runs. When you release the Joystick, the wheelchair is automatically braked. Use the speed control button to reduce or increase the speed setting. The Electric/ manual model change lever underneath the seat will allow for the brakes to engage or disengage. When adjusted to the manual model, the assistant can easily push the wheelchair. The Power Wheelchair has a structure for quick assembly and disassembly that is convenient to be stored or placed in the trunk of your vehicle while traveling.

    The Power Wheelchair has 7 inch front wheel and 12 inch rear tire.

    Max. distance of travel on the fully charged battery is 7.5 km and Max. speed forward is 6.48 km/h.

    When the wheelchair needs to stop, release the joystick. After a set period of time, the controller disconnects the solenoid brake power supply, and the internal spring squeezes the suction plate and friction plate to lock the motor, so as to brake.

    The braking time is about 2s, and the braking distance is ≤1.5m.

    AI/ML Overview

    Based on the provided FDA 510(k) clearance letter for the Vive Health LLC Power Wheelchair (MOB1107), here's an analysis addressing the acceptance criteria and study proving the device meets those criteria:

    The document describes a Class II medical device (Powered Wheelchair, Product Code: ITI) undergoing a 510(k) premarket notification process. This process focuses on demonstrating substantial equivalence to a predicate device rather than proving clinical efficacy or superiority through extensive clinical trials. Therefore, the "study that proves the device meets the acceptance criteria" primarily refers to non-clinical performance testing against established international standards for wheelchairs, rather than AI/software performance metrics often seen in other medical device clearances.

    Crucially, this document is for a physical medical device (power wheelchair), NOT a software/AI medical device. Many of the points you requested (e.g., number of experts, adjudication method, MRMC study, standalone AI performance, ground truth for training) are not applicable to this type of device clearance. The "performance" being evaluated here is mechanical, electrical, and safety performance of the wheelchair itself.


    Acceptance Criteria and Reported Device Performance

    The acceptance criteria for this power wheelchair are derived from international ISO standards for wheelchairs. The "reported device performance" is essentially a statement of compliance with these standards, indicating that various tests were conducted and the device met the specifications within those standards.

    Table of Acceptance Criteria and Reported Device Performance:

    Performance Aspect (Acceptance Criteria Reference Standard)Reported Device Performance (Subject Device K250729)
    Biocompatibility (Compliance with ISO 10993-5 and ISO 10993-10)All directly tissue-contacting materials are identical to the Predicate Device, with Right-of-Reference from the predicate manufacturer, implying compliance.
    Electromagnetic Compatibility (EMC) (ISO 7176-21 & IEC 60601-1-2)The EMC performance results meet the requirements.
    Static Stability (ISO 7176-1)Determined after testing according to ISO 7176-1; test results meet design specification.
    Dynamic Stability (ISO 7176-2)Determined after testing according to ISO 7176-2; test results meet design specification.
    Brake Effectiveness (ISO 7176-3)Determined after testing according to ISO 7176-3; test results meet design specification.
    Theoretical Distance Range (ISO 7176-4)Determined after testing according to ISO 7176-4; test results meet design specification.
    Dimensions & Mass (ISO 7176-5)Determined after testing according to ISO 7176-5.
    Dimensions & Mass (ISO 7176-6)Determined after testing according to ISO 7176-6.
    Seating & Wheel Dimensions (ISO 7176-7)Determined after testing according to ISO 7176-7.
    Static, Impact & Fatigue Strengths (ISO 7176-8)All test results meet requirements in Clause 4 of ISO 7176-8.
    Climatic Tests (Functionality after exposure) (ISO 7176-9)Device continued to function according to manufacturer's specification after being subjected to tests specified in Clause 8 of ISO 7176-9.
    Obstacle-climbing ability (ISO 7176-10)Determined after testing according to ISO 7176-10.
    Test Dummies suitability (ISO 7176-11)Test dummies used meet the requirements of ISO 7176-11.
    Coefficient of Friction of Test Surfaces (ISO 7176-13)Determined, for use in other 7176 series tests.
    Power and Control Systems (ISO 7176-14)All test results meet the requirements in Clause 7, 8, 9, 10, 11, 12, 13, 14, 15, 17 of ISO 7176-14.
    Information Disclosure, Documentation & Labeling (ISO 7176-15)Test results show information disclosure, documentation and labelling meet requirements.
    Resistance to Ignition (ISO 16840-10)Performance of resistance to ignition meets the requirements.
    Performance Testing Set-up Procedures (ISO 7176-22)ISO 7176-series performance testing used set-up procedures according to ISO 7176-22.
    Batteries and Chargers Performance (ISO 7176-25)Performance meets the requirements.
    Maximum Braking Distance (Implicit in ISO 7176-3)Reported as ≤0.9 m (Same as predicate, document states 2s braking time and ≤1.5m, but table says ≤0.9m). The document then clarifies "When you release the Joystick, the wheelchair is automatically braked. The braking time is about 2s, and the braking distance is ≤1.5m." The table comparison states "Braking distance ≤0.9m" and "Same" as predicate. This is a minor inconsistency in the summary but the acceptance is based on meeting the ISO 7176-3 design specification.
    Maximum Safe Operational Incline Degree (Implicit in Dynamic Stability)10° (Same as predicate).
    Maximum Speed Forward6.5 km/h (1.8 m/s) (Same as predicate).
    Maximum Obstacle Climbing25 mm (Predicate was 40mm, so this is a difference, but likely still within an acceptable standard).

    Inapplicable/Not Provided Information for a Physical Wheelchair 510(k):

    The following points are standard for AI/ML device submissions but are not applicable and therefore not provided in this traditional medical device 510(k) for a power wheelchair:

    1. Sample sizes used for the test set and the data provenance: Not relevant for physical device performance testing against engineering standards. The "samples" would be the manufactured wheelchairs tested. Data provenance typically refers to patient/clinical data, which isn't used for this type of device's "performance" evaluation.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. Ground truth for a physical device's performance (e.g., brake effectiveness, stability) is established by physical measurement against engineering standards, not expert consensus on medical images.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable. Adjudication methods are for human interpretation of data, typically medical images or clinical outcomes.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This is for AI/software devices.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable. This is for AI/software devices.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): For this device, the "ground truth" is defined by the technical specifications and testing methods outlined in the ISO 7176 series and IEC 60601-1-2 standards, confirmed by laboratory testing.
    7. The sample size for the training set: Not applicable. There is no AI/ML model for this device that requires training data.
    8. How the ground truth for the training set was established: Not applicable, as there is no training set for an AI/ML model.

    Summary of the "Study" Proving Substantial Equivalence and Meeting Criteria:

    The "study" proving the Vive Health LLC Power Wheelchair (MOB1107) meets acceptance criteria and is substantially equivalent to its predicate device (K242791) is based entirely on non-clinical laboratory performance testing and technical comparisons.

    • Study Design: The manufacturer performed a series of tests on the subject device according to the rigorous requirements of various international ISO 7176 series standards (for wheelchairs) and IEC 60601-1-2 (for electromagnetic compatibility/electrical safety).
    • Measurement: These tests involve direct physical measurements of parameters like static stability, dynamic stability, brake effectiveness, theoretical distance range, dimensions, weight, maximum speed, obstacle-climbing ability, as well as evaluating material biocompatibility and electrical safety.
    • Assessment of Compliance: The results of these tests were expected to "meet its design specification" or "meet the requirements" of the respective ISO standards. The submission asserts that the subject device's performance did meet these requirements.
    • Substantial Equivalence Argument: The core of the 510(k) submission is that because the subject device demonstrates comparable technical characteristics and achieves equivalent performance (as verified by these standard tests) to a legally marketed predicate device, it is considered "substantially equivalent" in terms of safety and effectiveness. The document explicitly states: "All these tests have corresponding requirements/ acceptance criteria following above mentioned standards. And the test results show that the subject device is within acceptable performance specifications and thus substantially equivalent to the predicate device in performance."
    • No Clinical Studies: The document explicitly states, "No animal study and clinical studies are available for our device. Clinical testing was not required to demonstrate the substantial equivalence of the power wheelchair to its predicate device." This reinforces that the safety and performance were established through non-clinical, engineering-based testing.
    Ask a Question

    Ask a specific question about this device

    K Number
    K251606

    Validate with FDA (Live)

    Date Cleared
    2025-06-25

    (29 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The power wheelchair is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The power wheelchair, model name:D26, is an indoor/outdoor, foldable, battery-operated 2-wheel (rear-wheel drive) powered wheelchair. It consists of two parts: the electrical part and the wheelchair main body. The electric part includes brushless motor, electromagnetic brake system, controller, rechargeable Lithium-Ion battery and off-board battery charger. The main parts of the wheelchair include front wheels, rear wheels, frame, armrest, backrest and seat cushion.

    The control system, including the controller handle (joystick), is equipped on the control pad that attaches to the one of the arm rests. When the joystick is released, the electromagnetic brakes will be actuated, and the power wheelchair is slowed to a stop.

    The power wheelchair, model name: D26, can be controlled by joystick or remote controller via Bluetooth Low Energy (BLE) wireless communication interface. The user can lock and unlock the device remotely via the BLE interface using the remote controller. For safety, controller rocker control is priority over the remote control by design.

    The power wheelchair can be folded/ expanded manually. The Left and right handrails (joystick) can be interchange.

    AI/ML Overview

    This document is a 510(k) clearance letter for a Power Wheelchair (D26), not a software or AI-enabled medical device. Therefore, the provided information does not contain the details typically sought in an acceptance criteria and study report for AI/ML devices.

    The 510(k) process for a physical device like a power wheelchair focuses on demonstrating substantial equivalence to a previously cleared predicate device, primarily through engineering and performance testing against recognized standards, rather than clinical studies with human subjects in the same way an AI-driven diagnostic tool would be evaluated.

    Here's why the AI/ML-specific questions cannot be answered from this document:

    • No AI/ML Component: The device description clearly indicates it's a "motor driven, indoor and outdoor transportation vehicle" with components like motors, brakes, joystick control, and Bluetooth remote control. There is no mention of artificial intelligence, machine learning, or algorithms that perform diagnostic or interpretative functions.
    • Performance Evaluation Type: The "study that proves the device meets the acceptance criteria" in this context refers to various engineering and safety tests outlined in the ISO 7176 series and IEC 60601-1-2 standards (e.g., static ability, dynamic stability, brake performance, biocompatibility, EMC). These are objective, quantitative tests of the device's physical properties and functionality.

    Therefore, it is not possible to fill out the table and answer the questions about AI/ML device performance, ground truth, expert adjudication, or MRMC studies based on the provided FDA 510(k) document.

    This document demonstrates substantial equivalence for a physical medical device by comparing its technical specifications and performance against international standards for wheelchairs.

    However, if you're looking for an example of how a 510(k) for a non-AI/ML device does define acceptance criteria and demonstrates compliance, here's an interpretation based on the provided text:


    Acceptance Criteria and Study for Power Wheelchair (D26)

    The device, a Power Wheelchair (D26), is primarily evaluated based on its adherence to established international standards for wheelchairs and its substantial equivalence to a predicate device (K242448, Power Wheelchair, D26 from the same manufacturer). The "acceptance criteria" are derived from these standards and the comparative analysis with the predicate.

    1. Table of Acceptance Criteria and Reported Device Performance

    AttributeAcceptance Criteria (based on standards/predicate)Reported Device Performance (Subject Device)Discussion/Conclusion (from document)
    General Characteristics
    Device Classification NameClass IIClass IISame
    Regulatory Class21 CFR 890.386021 CFR 890.3860Same
    Indications for UseProvide mobility to a disabled or elderly person limited to a seated position, for indoor & outdoor transportation."The power wheelchair is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position."Same
    Key Performance ParametersNote: All listed attributes below are explicitly stated as "Same" with the predicate device, or differences are explained as not raising new safety/effectiveness concerns. The acceptance criteria imply matching or exceeding predicate performance/standards.
    Max Speed ForwardUp to 6 km/h (3.75 mph)Up to 6 km/h (3.75 mph), continuously adjustableSame
    Minimum Braking Dist. (from max speed)Forward: <1mForward: <1mSame
    Maximum Safe Operational InclineSame
    Max Loading Weight120kg (Predicate)180kgMinor difference: "more loading weight provide more convenient and stable performance for the transportation." (Deemed acceptable)
    Maximum Distance of Travel (Fully Charged Battery)20 km (Predicate)12.8 kmMinor difference: "Minor difference on travel distance will not cause different performance. This difference will not raise any new safety and effectiveness concerns." (Deemed acceptable)
    Turning Radius750mm750mmSame
    Maximum Obstacle Climbing25 mm25 mmSame
    Safety and Standards Compliance
    BiocompatibilityCompliance with ISO 10993-1, ISO 10993-5:2009, ISO10993-10:2010/ ISO 10993-23:2021 (for directly contacting materials)"All user directly contacting materials are compliance with ISO 10993-1" and "meet the requirements of the ISO 10993-5:2009 & ISO10993-10:2010/ ISO 10993-23:2021."Same. Although standard version updated, methods are same.
    EMCCompliance with ISO 7176-21 & IEC 60601-1-2"ISO 7176-21 & IEC60601-1-2"Same
    Performance StandardsCompliance with ISO 7176 series (e.g., -1, -2, -3, -4, -5, -6, -7, -8, -9, -10, -11, -13, -14, -15, -21, -22, -25) and ISO 16840-10:2021Document states: "proposed device and predicate device are complying to the same ISO standards" and "All these tests have corresponding requirements/ control criteria following above mentioned standards. And the test results show that the subject product is substantially equivalent to the predicate device in performance." Specific tests performed include Static ability, Dynamic stability, Brake performance, Theoretical distance range, Dimension and weight, Maximum speed, Dimension of wheel Static, impact and fatigue strengths, Climatic tests, Obstacle-climbing ability, Dummy, friction of test surfaces, Power and control systems, Documentation and labeling, Resistance to ignition, Electromagnetic Compatibility and Electrical Safety, Batteries and chargers.Same. Performance testing demonstrates substantial equivalence.
    LabelingConforms to FDA Regulatory"Conforms to FDA Regulatory"Same

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: Not applicable in the context of an "AI/ML test set." For a physical device, the "test set" refers to the specific physical unit(s) of the Power Wheelchair D26 that underwent engineering and performance testing. The document implies a sufficient number of units were tested to demonstrate compliance with the referenced ISO standards. The exact number of units tested is not specified in the public 510(k) summary, but typically, testing would be performed on representative production units.
    • Data Provenance: The testing was conducted by Anhui JBH Medical Apparatus Co., Ltd. (manufacturer) in China, as indicated by the company's address. The data is prospective in the sense that it's generated specifically for this premarket notification as part of device design verification and validation.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Not Applicable. For a physical device like a power wheelchair, "ground truth" is established by objective engineering measurements against defined performance specifications in international standards (e.g., maximum speed, braking distance, incline stability). These are not subjective interpretations requiring human experts for "ground truth" establishment in the way medical image analysis or clinical diagnosis would. The compliance is evaluated by qualified test engineers and regulatory professionals against the standard requirements.

    4. Adjudication Method for the Test Set

    • Not Applicable. There is no "adjudication" necessary as the tests are objective, quantitative measurements against predefined criteria in the relevant standards.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    • No. This type of study is specifically relevant for AI/ML diagnostic or interpretive devices where human reader performance (e.g., radiologists, pathologists) is being compared with and without AI assistance. This is a physical, mobility device, not a diagnostic tool.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    • Not Applicable. There is no standalone algorithm being evaluated. The device functions as a complete physical system controlled by a human user with a joystick or remote.

    7. The Type of Ground Truth Used

    • Objective Engineering Specifications and International Standards: The "ground truth" for the device's performance is defined by the objective, measurable parameters and performance requirements outlined in the cited ISO 7176 series standards, IEC 60601-1-2, and biocompatibility standards (ISO 10993 series). For example, the braking distance being less than 1m or the maximum incline being 8 degrees are the "ground truth" metrics.

    8. The Sample Size for the Training Set

    • Not Applicable. This is a physical medical device. There is no AI/ML model or "training set" in the context of machine learning. The device's design and manufacturing process are based on established engineering principles and prior experience, not data-driven AI training.

    9. How the Ground Truth for the Training Set Was Established

    • Not Applicable. As there is no AI/ML training set, this question is not relevant. The "ground truth" for the device's design and manufacturing are the universally accepted principles of mechanical, electrical, and materials engineering, combined with industry best practices and regulatory standards for safety and performance.
    Ask a Question

    Ask a specific question about this device

    K Number
    K250134

    Validate with FDA (Live)

    Date Cleared
    2025-03-26

    (68 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    It is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The subject device, Power Wheelchair, mainly powered by battery, motivated by DC motor, driven by user controlling joystick controller and adjusting speed. The power wheelchair is a battery powered four wheel t consists Li-ion battery with an off-board battery charger, Push handle, Seat, Back support, Joystick control panel(including: Battery indicate, ON/OFF button, Horn, Gear indicator, Accelerated button, Deceleration button), Arm supports, Anti-tip wheel, Front wheels. The operation of the scooter: Use the On/Off button to turn on or turn off the power, The main function of the Joystick is to control the speed and direction of the Joystick can control the wheelchair to travel in any direction, the operation of the Joystick movement will deternine the wheelchair in that direction speed of movement. The farther the Joystick is moving from the center, the wheelchair uns. When you release the Joystick, the wheelchair is automatically braked. Use the speed control button to reduce or increase the speed setting. The Electric / manual model the seat will allow for the brakes to engage. When adjusted to the manual model, the assistant can easily push the wheelchair. The power wheelchair has a structure for quick assembly and disassembly that is convenient to be stored or placed in the trunk of your vehicle while traveling.

    AI/ML Overview

    The provided text is a 510(k) premarket notification letter from the FDA regarding a power wheelchair. It discusses the regulatory classification, general controls, and compliance with regulations.

    However, the document does not contain any information about acceptance criteria or a study that proves a device meets those criteria for an AI/ML medical device. The product is a "Power Wheelchair," which is a physical medical device, not a software or AI/ML device. The "Non-Clinical and/or Clinical Tests Summary & Conclusions" section lists various ISO standards that the power wheelchair complies with, such as tests for static stability, dynamic stability, effectiveness of brakes, energy consumption, etc. These are engineering standards for mechanical and electrical safety and performance, not AI/ML performance metrics.

    Therefore, I cannot extract the requested information as it is not present in the provided document.

    To fulfill your request, I would need a document that describes the development and validation of an AI/ML medical device, which would typically include:

    • Details on the algorithm's functionality.
    • Specific performance metrics (e.g., sensitivity, specificity, AUC, F1-score for classification tasks; RMSE, MAE for regression during inference).
    • Test set characteristics (size, provenance).
    • Ground truth establishment methods (expert consensus, pathology, follow-up outcomes).
    • Details of any human-in-the-loop studies (MRMC).
    • Training data characteristics.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242448

    Validate with FDA (Live)

    Date Cleared
    2025-01-02

    (139 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The power wheelchair is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The power wheelchair, model name: D03, D05, D06, D09, D11, D16, D22, D23, D26, D36, is an indoor/outdoor, foldable, battery-operated 2-wheel drive) powered wheelchair. It consists of two parts: the electrical part and the wheelchair main body. The electric part includes brushless motor, electromagnetic brake system, controller, rechargeable Lithium-lon battery and off-board battery charger. The main parts of the wheelchair include front wheels, rear wheels, frame, armrest, backrest and seat cushion. The control system, including the controller handle (joystick), is equipped on the control pad that attaches to the one of the arm rests. When the joystick is released, the electromagnetic brakes will be actuated, and the power wheelchair is slowed to a stop. The power wheelchair, model name: D03, D05, D06, D09, D11, D16, D22, D23, D26, D36, can be controlled by joystick or remote controller via Bluetooth Low Energy (BLE) wireless communication interface. The user can lock and unlock the device remotely via the BLE interface using the remote controller. For safety, controller rocker control is priority over the remote control by design. The power wheelchair can be folded/ expanded manually. The Left and right handrails (joystick) can be interchange.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the Power Wheelchair, based on the provided document.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria for the Power Wheelchair (models D03, D05, D06, D09, D11, D16, D22, D23, D26, D36) are implicitly defined by compliance with a comprehensive set of ISO standards. The reported device performance is indicated by the statement that the device met all design specifications and passed all tests.

    Attribute TestedAcceptance Criteria (Standard Reference)Reported Device Performance
    Static StabilityISO 7176-1:2014Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance."
    Dynamic StabilityISO 7176-2:2017Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance."
    Brake EffectivenessISO 7176-3:2012Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance."
    Energy consumption/Distance RangeISO 7176-4:2008Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance." (Specific distances: 23km for D36, 20km for other models)
    Dimensions, Mass, ManeuveringISO 7176-5:2008Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance." (Specific dimensions listed in Table 2, with minor differences noted but deemed not to affect safety/effectiveness: Length 930-1150mm, Width 530-658mm, etc.)
    Maximum Speed, Accel., Decel.ISO 7176-6:2018Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance." (Max speed: Up to 6 km/h)
    Seating/Wheel DimensionsISO 7176-7:1998Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance."
    Static, Impact, Fatigue StrengthISO 7176-8:2014Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance."
    Climatic TestsISO 7176-9:2009Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance."
    Obstacle-Climbing AbilityISO 7176-10:2008Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance." (Obstacle climbing: 20mm for some models, 25mm for others, 40mm for D36)
    Test DummiesISO 7176-11:2012Test methodologies using standard test dummies were employed. Results implicitly support substantial equivalence.
    Coefficient of FrictionISO 7176-13:1989Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance."
    Power and Control SystemsISO 7176-14:2022Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance."
    Information Disclosure/LabelingISO 7176-15:1996 & FDA Regulatory requirementsConforms to FDA Regulatory. Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance."
    Resistance to IgnitionISO 16840-10:2021Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance."
    Electromagnetic Compatibility (EMC)ISO 7176-21:2009 & IEC 60601-1-2:2020 & ANSI C63.27:2021Met all design specifications; passed all tests. "Extra wireless coexistence testing was conducted and passed." "Subject product is substantially equivalent to the predicate device in performance."
    Batteries and ChargersISO 7176-25:2013 & IEC 62133-2:2017Met all design specifications; passed all tests. "Subject product is substantially equivalent to the predicate device in performance." (Battery types and charger specifications detailed in Table 2).
    BiocompatibilityISO 10993-1:2018 (including -5, -10, -23)All user directly contacting materials are compliant. Met all design specifications; passed all tests. "Biocompatibility Tests are carried out in accordance with ISO 10993-1: 2018, including cytotoxicity (ISO 10993-5:2009), sensitization (ISO 10993-10:2021) and irritation (ISO 10993-23: 2021)."
    Software ValidationNot explicitly referenced, but stated as performedPerformed. "Subject product is substantially equivalent to the predicate device in performance."
    Risk AnalysisISO 14971:2019Developed in accordance with the standard.
    Functional Performance (Bluetooth)FCC 47 CFR 15.247 and RF exposure requirementsThe Bluetooth remote control was validated to be effective and does not raise new safety or effectiveness issues. Minor difference in frequency range, but compliance ensured.
    CybersecurityNot explicitly referenced, but stated as validatedValidated to be effective and does not raise new issues of safety or effectiveness.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: The document does not specify a distinct "test set" in terms of patient data or images. Instead, the testing refers to physical devices (the specific models D03, D05, D06, D09, D11, D16, D22, D23, D26, D36) and their components. The tests performed are bench tests conducted on these physical devices to verify their performance against engineering standards.
    • Data Provenance: Not applicable as the testing involves physical device performance, not data from human subjects. The testing is prospective in the sense that the manufacturer tested their newly designed device models to confirm compliance. The manufacturing location is Anhui, China.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. This is a technical performance study of a physical device against engineering standards. Ground truth as typically defined for AI/diagnostic studies (e.g., expert consensus on medical images) is not relevant here. The "ground truth" is defined by the technical specifications and requirements of the referenced ISO standards.

    4. Adjudication Method for the Test Set

    Not applicable. There is no human interpretation or consensus required for the test results; the tests involve quantifiable measurements (e.g., stability angles, braking distances, electrical properties) that either meet or do not meet the specified criteria in the standards.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No. An MRMC study is not relevant for this type of device (a power wheelchair). It's typically used for evaluating diagnostic or screening tools where human readers interpret patient data (e.g., radiology images).

    6. If a Standalone Study (i.e., Algorithm Only Without Human-in-the-Loop Performance) Was Done

    Yes, in essence, the entire suite of non-clinical bench testing constitutes a "standalone" evaluation of the device's physical and electrical performance without human operation as a variable beyond what is required to execute the test protocols. The Bluetooth remote control functionality (a form of "algorithm") was also tested in a standalone manner for effectiveness and cybersecurity.

    7. The Type of Ground Truth Used

    The "ground truth" (or reference standard) for these tests is the quantitative and qualitative requirements set forth in the extensive list of ISO and IEC engineering standards (e.g., ISO 7176 series, IEC 62133-2, IEC 60601-1-2, ANSI C63.27, ISO 14971, ISO 10993 series). These standards define the acceptable performance limits and test methodologies for power wheelchairs.

    8. The Sample Size for the Training Set

    Not applicable. This is not an AI/ML device where a "training set" of data is used for model development. The development process would involve engineering design and iterative prototyping, not data-driven model training.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for an AI/ML model.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242468

    Validate with FDA (Live)

    Date Cleared
    2024-12-31

    (133 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The power wheelchair is a motor driven, indoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The power wheelchair, model name: D10, D12, D15, D17, D20, D37, is an indoor/outdoor, foldable, battery-operated 2-wheel (rear-wheel drive) powered wheelchair. It consists of two parts: the electrical part and the wheelchair main body. The electric part includes brushless motor, electromagnetic brake system, controller, rechargeable Lithium-lon battery and off-board battery charger. The main parts of the wheelchair include front wheels, rear wheels, frame, armrest, backrest and seat cushion. The control system, including the controller handle (joystick), is equipped on the control pad that attaches to the one of the arm rests. When the joystick is released, the electromagnetic brakes will be actuated, and the power wheelchair is slowed to a stop. The power wheelchair, model name: D10, D12, D15, D17, D20, D37, can be controlled by joystick or remote controller via Bluetooth Low Energy (BLE) wireless communication interface. The user can lock and unlock the device remotely via the BLE interface using the remote controller. For safety, controller rocker control is priority over the remote control by design. The power wheelchair (Model D10, D12, D15, D17, D20, D37) can be folded/ expanded manually. The Left and right handrails (joystick) can be interchange. The D17 power wheelchair has an additional headrest and its seat unit can be adjusted by a remote control key to a largest angle of 30°.

    AI/ML Overview

    The provided text is a 510(k) Premarket Notification from the FDA for a Power Wheelchair. It describes the device, compares it to predicate devices, and outlines the non-clinical testing performed to establish substantial equivalence. However, it does not contain information about a study proving the device meets acceptance criteria related to AI/ML performance, human reader improvement with AI assistance, or expert ground truth establishment for medical imaging or similar AI applications.

    The document explicitly states:

    • "No animal study and clinical studies are available for our device. Clinical testing was not required to demonstrate the substantial equivalence of the power wheelchair to its predicate device." (Page 17, Section IX)
    • The comparison tables (Table 1, Table 2, Table 3) detail physical, mechanical, and electrical characteristics, and safety standards met (ISO, IEC, EMC, biocompatibility). These are engineering and safety performance criteria for a wheelchair, not AI/ML performance.

    Therefore, I cannot provide the requested information regarding AI/ML acceptance criteria and a study that proves the device meets those criteria, as the provided text pertains to a power wheelchair and not a medical device involving AI/ML for diagnostic or therapeutic purposes.

    If you have a document describing an AI/ML medical device and its validation study, please provide that, and I will be able to answer your questions.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242252

    Validate with FDA (Live)

    Device Name
    Power Wheelchair
    Date Cleared
    2024-12-27

    (149 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The power wheelchair is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The power wheelchair, model name: DC01, DC02, DC03, DC05, DC06, DC07L, DC08L, DC09L, DC10L, is an indoor/outdoor, foldable, battery-operated 2-wheel (rear-wheel drive) powered wheelchair. It consists of two parts: the electrical part and the wheelchair main body. The electric part includes brushless motor, electromagnetic brake system, controller, rechargeable Lithium-lon battery and off-board battery charger. The main parts of the wheelchair include front wheels, rear wheels, frame, armrest, backrest and seat cushion. The control system, including the controller handle (joystick), is equipped on the control pad that attaches to the one of the arm rests. When the joystick is released, the electromagnetic brakes will be actuated, and the power wheelchair is slowed to a stop. The power wheelchair, model name: DC01, DC02, DC03, DC05, DC06, DC07L, DC08L, DC09L, DC10L, can be controlled by joystick or remote controller via Bluetooth Low Energy (BLE) wireless communication interface. The user can lock and unlock the device remotely via the BLE interface using the remote controller. For safety, controller rocker control is priority over the remote control by design. The wheelchair can be folded/expanded manually. The Left and right handrails (joystick) can be interchange.

    AI/ML Overview

    The provided text describes a 510(k) submission for a power wheelchair and does not contain information about acceptance criteria and a study that proves a device meets those criteria in the context of an AI/ML medical device.

    The document is a letter from the FDA regarding a premarket notification for a Power Wheelchair. It focuses on the substantial equivalence of the proposed device to legally marketed predicate devices based on non-clinical performance testing (bench testing), adherence to ISO standards for wheelchairs, and material biocompatibility.

    Therefore, I cannot extract the requested information (such as AI/ML performance metrics, sample sizes for test/training sets, expert qualifications, adjudication methods, or MRMC studies) because the document does not pertain to an AI/ML device study.

    The closest information available is related to non-clinical performance testing for the physical safety and performance of a wheelchair, not an AI/ML algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242308

    Validate with FDA (Live)

    Device Name
    Power wheelchair
    Date Cleared
    2024-11-27

    (114 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    It is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    This product consists of frame, wheels, seat, armrest, lithium battery, motor and controller with a lightweight and compact design. The whole wheelchair can be folded by one button and it can be easily carried or rolled after folding. The seat cushion is detachable. The armrest can be flipped backward, which is convenient for the elderly to move. Users can drive the wheelchair by themselves through the control device. The wheelchair uses lithium batteries as its power source. The controls the drive left/right motor to realize the wheelchair forward, backward and turn functions. The frame of the device is carbon fiber. The front wheels are driven wheels suitable for rotation, acceleration, retrograde and other actions of the wheelchair. The front wheels movement will be achieved by thrust generated from the rear wheels. The rear wheels are driving wheels to control the speed and direction. The wheels are Solid PU tires. When in use, the operator drives the motor of the rear wheel by operating the joystick to achieve the rear wheels movement. The DC brushless motor and brake system are fixed on the rear wheels. The max loading of the device is 136KG. Only for one person sit.

    AI/ML Overview

    This document is an FDA 510(k) Premarket Notification for a Power Wheelchair (Model N6102). It aims to demonstrate substantial equivalence to a predicate device (K230964). Since this is a submission for a physical medical device (a power wheelchair) and not a software/AI-driven diagnostic or therapeutic device, the concepts of acceptance criteria, test sets, ground truth establishment, expert adjudication, MRMC studies, and separate training/test sets are not applicable in the context of typical AI/ML device evaluations.

    The "acceptance criteria" and "study that proves the device meets the acceptance criteria" for a power wheelchair primarily revolve around compliance with recognized performance and safety standards (ISO 7176 series, IEC 60601-1-2, ISO 10993 series) and demonstrating that any differences from a predicate device do not raise new safety or effectiveness concerns.

    Here's how to interpret the provided information in the context of device acceptance, organized to address your prompt's structure where applicable, but noting the non-applicability of certain AI/ML-specific terms:

    1. A table of acceptance criteria and the reported device performance

    The document provides a comparison of the proposed device against a predicate device, largely referencing compliance with international standards. The "acceptance criteria" are implied by these standards and the "reported device performance" is the statement of compliance or comparison to the predicate.

    Acceptance Criteria (Implied by Standard/Predicate)Reported Device Performance (Subject Device)Discussion/Remark (from document)
    General Characteristics
    ClassificationClass IISame
    Product CodeITISame
    Indications for UseMotor driven, indoor/outdoor transportation for disabled/elderly limited to seated position.S.E. (Substantially Equivalent)
    Intended UserDisabled or elderly person limited to a seated position.S.E.
    Use ConditionIndoor and outdoor useS.E.
    Driving SystemDirect drive on the rear wheelsS.E.
    Brake SystemAutomatic electromagnetic brake systemS.E.
    Armrest MaterialT700 (Predicate)Carbon fibers
    Main Frame MaterialCarbon fiber materialCarbon fiber material
    Back Cushion MaterialPolyester fabric (Predicate)Polyester fiber
    Seat Cushion MaterialPolyester fiberPolyester fiber
    Number of Wheels4 (two front, two rear)4 (two front, two rear)
    Function of WheelsFront: driven for rotation, acceleration, retrograde; Rear: driving for speed/direction.Same
    Movement ControlBy Joystick controlBy Joystick control
    Battery (Type & Specs)li-ion battery pack, 24V, 10Ahli-ion battery pack, 24V, 10Ah
    Battery Charger (Type & Specs)Off-board, Input: 100-240V, 50/60Hz, 1.5A; Output: 24Vdc, 2ASame
    Motor (Type & Specs)Brushless DC motor; 24VDC; 150W; 2pcsBrushless Eco-Drive, 24V, 150W, 2pcs
    Electronic ControllerBrushless dual-drive rocker controllerBrushless dual-drive rocker controller
    Turning Radius900mm900mm
    Performance Characteristics
    Braking Distance≤1.5 m (Predicate)780mm
    Maximum Safe Operational Incline Degree
    Overall Dimension (LWH)900580860mm (Predicate)950610960mm
    Front Wheel Size/Type7" x 1.75"/PU Solid tire (Predicate)7" x 1.78"/PU Solid tire (180mm x 45mm)
    Rear Wheel Size/Type8.5" x 1.8"/PU Solid tire (Predicate)9" x 2"/PU Solid tire (230mm x 50mm)
    Max Speed ForwardUp to 6 km/h (1.6 m/s), adjustable (Predicate)1.54 m/s (5.5km/h)
    Max Loading Weight110kg (≈250lbs) (Predicate)136kg (≈300lbs)
    Maximum Distance of Travel on Fully Charged Battery10 km (Predicate)16.1km
    Maximum Obstacle Climbing40 mm (Predicate)25mm
    Safety & Compliance (Implied by Standards)
    BiocompatibilityISO10993-5, ISO10993-10, ISO10993-23 requirementsCompliance with ISO10993-5, ISO10993-10, ISO10993-23
    EMC PerformanceISO7176-21 and IEC 60601-1-2Compliant with ISO7176-21 and IEC 60601-1-2
    General PerformanceISO7176 seriesCompliant with ISO7176 series
    Label and LabelingConforms to FDA RegulatoryConforms to FDA Regulatory
    Specific ISO Standard Compliance
    ISO 7176-1 (Static Stability)Meets design specificationMeets design specification
    ISO 7176-2 (Dynamic Stability)Meets design specificationMeets design specification
    ISO 7176-3 (Brakes Effectiveness)Meets design specificationMeets design specification
    ISO 7176-4 (Theoretical Distance Range)Meets design specificationMeets design specification
    ISO 7176-5 (Dimensions, Mass)Determined/MeetsDetermined/Meets
    ISO 7176-6 (Dimensions, Mass)Determined/MeetsDetermined/Meets
    ISO 7176-7 (Seating & Wheel Dimensions)Determined/MeetsDetermined/Meets
    ISO 7176-8 (Requirements)All test results meet requirementsAll test results meet requirements
    ISO 7176-9 (Dynamic Tests)Continue to function after testsContinue to function after tests
    ISO 7176-10 (Obstacle-climbing ability)Determined/MeetsDetermined/Meets
    ISO 7176-11 (Test Dummies)Meet requirementsMeet requirements
    ISO 7176-13 (Coefficient of Friction)Determined for use in other 7176 series testsDetermined for use in other 7176 series tests
    ISO 7176-14 (Requirements)All test results meet requirementsAll test results meet requirements
    ISO 7176-15 (Information Disclosure, Labeling)Meets requirementsMeets requirements
    ISO 16840-10:2021 (Fire Resistance)Performance meets requirementsPerformance meets requirements
    ISO 7176-25 (Batteries and Charger)Performance meets requirementsPerformance meets requirements

    2. Sample sizes used for the test set and the data provenance

    This information is not provided as it's not relevant for a direct testing of a physical device against standards (e.g., you test a specific number of manufactured units or prototypes for compliance, not a "data set"). The provenance isn't applicable in the same way either; the tests are performed on the device.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. "Ground truth" in the context of device performance is established by the specified ISO standards and validated test methods (e.g., a test rig for stability or braking) and direct measurements. It doesn't rely on expert consensus in the same way an AI diagnostic image reading might.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. As above, the "truth" is determined by objective measurements against engineering standards, not through a consensus of human interpretative results.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This study is for a physical power wheelchair, not an AI software. There are no "human readers" or "AI assistance" in its intended function or evaluation.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device does not contain an algorithm in this context. Its "performance" is mechanical and electrical, not computational.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" for this device's performance is derived from:

    • International Standards: Primarily the ISO 7176 series, IEC 60601-1-2, and ISO 10993 series, which define objective test methods and acceptable performance limits for wheelchairs.
    • Engineering Specifications: The design specifications for the device itself (e.g., max speed, loading weight, dimensions).
    • Physical Testing: Direct physical measurements and tests on the device (e.g., dynamic stability tests, braking distance tests, obstacle climbing tests).

    8. The sample size for the training set

    Not applicable. This is a physical device, not an AI/ML model that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable. See point 8.

    In summary, the "study" proving the device meets the "acceptance criteria" is a series of engineering tests and analyses demonstrating compliance with relevant international performance and safety standards for power wheelchairs, and a comparison to a legally marketed predicate device to demonstrate substantial equivalence. The differences noted (e.g., slightly different dimensions, braking distance, max loading weight, travel distance, obstacle climbing) are all deemed not to raise new safety or effectiveness concerns, with testing conducted to confirm compliance with the applicable standards even with these differences (e.g., "All safety and performance have been validated with the maximum rated weight dummy").

    Ask a Question

    Ask a specific question about this device