Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K121383

    Validate with FDA (Live)

    Date Cleared
    2012-09-05

    (120 days)

    Product Code
    Regulation Number
    876.5630
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The "X" Series PD Catheter is indicated for peritoneal dialysis in adults. It is intended for use in patients who are poor candidates for conventional peritoneal dialysis catheters and are candidates for presternal insertion.

    The "X" Series Catheter is indicated for chronic peritoneal dialysis.

    The extended length of the “X” Series Catheter makes it especially applicable for peritoneal dialysis patients when it is necessary to locate the skin exit site remote from the usual lower abdominal region. The catheter may be particularly indicated in patients with obesity, floppy abdominal skin folds, urinary or fecal incontinence, chronic yeast intertrigo, intestinal stomas, or in patients who desire to take deep tub baths.

    Device Description

    The "X" Series PD Catheter is comprised of a silicone rubber, coiled tip, single polyester cuff abdominal catheter segment that is joined with a titanium double bared connector to a silicone rubber, double polyester cuff subcutaneous extension catheter possessing a preformed tubing arc bend between the two cuffs. The abdominal catheter segment is implanted into the peritoneal cavity. The attached subcutaneous extension piece allows remote location of the catheter skin exit site away from the lower abdominal region.

    The catheter will be sold in two kit configurations, as the catheter only with a female luer, clamp, and male luer end cap and titanium connector. The catheter set will also include the addition of a dilator/sheath introducer, guidewire, scalpel, introducer needle, tunneling tool, gauze pads and syringe.

    AI/ML Overview

    The provided text describes a medical device, the "X" Series PD Catheter, and its substantial equivalence to predicate devices, but does not contain information about acceptance criteria or a specific study proving the device meets those criteria in the context of AI/ML performance.

    Instead, the document focuses on:

    • Device Description: What the "X" Series PD Catheter is made of and how it's constructed.
    • Intended Use and Indications for Use: For peritoneal dialysis, especially in patients with specific conditions like obesity or stomas, where a remote exit site is beneficial.
    • Comparison to Predicate Devices: Asserting substantial equivalence in terms of intended use, materials, design, performance, etc.
    • Performance Testing (Non-Clinical): A list of physical and material tests performed (e.g., Air Leakage, Gravity Flow, Biocompatibility).
    • Regulatory Information: 510(k) summary, classification, product codes, and the FDA's substantial equivalence determination.

    Therefore, I cannot provide the requested information regarding acceptance criteria, study details, human readers, ground truth establishment, or training/test set sizes because this information is not present in the provided text. The performance testing mentioned (Air Leakage, Liquid Leakage, etc.) are engineering/materials tests for the physical catheter, not a clinical study or AI/ML performance evaluation.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1