    Intended Use

    Prodigy® AutoCode® Eject Blood Glucose Monitoring System is intended to be used for the quantitative measurement of glucose (sugar) in fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, palm, calf or thigh. The Prodigy® AutoCode® Eject Blood Glucose Monitoring System is intended to be used by a single person and should not be shared. The Prodigy® AutoCode® Eject Blood Glucose Monitoring System is intended for self-testing outside the body (in vitro diagnostic use) by people with diabetes at home as an aid to monitor the effectiveness of diabetes control. The Prodigy® AutoCode® Eject Blood Glucose Monitoring System should not be used for the diagnosis of, or screening for diabetes, or for neonatal use. The alternative site testing should be done only during steady-state times (when glucose is not changing rapidly).

    PRODIGY® No Coding Test Strips are intended for use with the PRODIGY® AutoCode® Eject blood glucose meter to measure the concentration of the blood glucose in fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, palm, calf or thigh for self-testing at home. They are for testing outside the body (in vitro diagnostic use only) . Do not use them for diagnosis of, or screening for dabetes or for testing on neonates. PRODIGY® No Coding Test Strips are used as an aid to monitor the effectiveness of diabetes control.

    This system contains a speaking function, but is not intended for use by the visually impaired.

    Device Description

    The Prodigy® AutoCode® Eject Blood Glucose Monitoring System consists of a meter and Prodigy No Coding Test Strips. The system utilizes an electrochemical method-based meter and dry reagent biosensor (test strips) for blood glucose testing. The size of the current is proportional to the amount of glucose present in the sample, providing a quantitative measurement of glucose in fresh whole blood and control solutions.

    The Prodigy® AutoCode® Eject Blood Glucose Monitoring System is marketed as a meter only with a carrying case, batteries, Owner's Manual, Quick Reference Guide, Logbook, and Warranty Card.

    The Prodigy® AutoCode® Eject Blood Glucose Monitoring System is also marketed as a meter kit with a carrying case, batteries, Owner's Manual, Quick Reference Guide, Logbook, and Warranty Card, Prodigy Lancing Device, Prodigy Lancets, Prodigy No Coding Test Strips, and Control Solution.

    The Prodigy No Coding Test Strips utilizes the active enzyme is Glucose Oxidase, derived from Aspergillus niger. The Prodigy® AutoCode® Eject Blood Glucose Monitoring System has a speaking function.

    AI/ML Overview

    The provided text describes the Prodigy® AutoCode Eject TM Blood Glucose Monitoring System and its substantial equivalence to a predicate device. However, it does not contain the detailed study information (sample sizes, expertise, ground truth establishment) typically associated with acceptance criteria for an AI/ML medical device submission.

    The document is a 510(k) summary for an in vitro diagnostic (IVD) device, specifically a blood glucose monitoring system, which measures glucose using an electrochemical method. These devices are generally tested against analytical and clinical performance standards rather than requiring AI-specific study designs like MRMC studies.

    Here's a breakdown of the available information, noting the absence of AI/ML-specific details:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state acceptance criteria in the format of a table with specific thresholds for accuracy, precision, sensitivity, or specificity. Instead, it relies on demonstrating substantial equivalence to a predicate device (PRODIGY Preferred® Blood Glucose Monitoring System, K122338) that has already met regulatory requirements.

    The "Synopsis of Test Methods and Results" section generally states that "Pre-clinical and clinical data are employed upon submission of this 510(K) premarket notification according to the Guidance Document for In Vitro Diagnostic Test System; Guidance for Industry and FDA document provided by CDRH/FDA." This indicates that standard analytical and clinical performance studies for blood glucose meters were conducted, but the specific results or acceptance criteria are not detailed in this summary.

    2. Sample Size Used for the Test Set and Data Provenance

    This information is not provided in the document. The 510(k) summary only mentions that "Pre-clinical and clinical data are employed," but does not detail the sample size for any test sets or the provenance (country of origin, retrospective/prospective) of the data.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not provided in the document. For blood glucose monitoring systems, ground truth is typically established by comparing the device's readings against a laboratory reference method (e.g., a YSI analyzer), not through expert consensus.

    4. Adjudication Method for the Test Set

    This information is not provided in the document. Adjudication methods like 2+1 or 3+1 are typical for interpreting subjective data (e.g., medical images) where human agreement is required to establish ground truth. For quantitative measurements like blood glucose, adjudication is not typically relevant at the point of establishing ground truth against a reference method.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study Was Done

    No, a Multi Reader Multi Case (MRMC) comparative effectiveness study was not done or at least not reported in this 510(k) summary. These studies are specific to AI/ML devices that assist human readers in tasks like image interpretation. The Prodigy® AutoCode Eject TM Blood Glucose Monitoring System is a standalone diagnostic device that provides a direct quantitative measurement of glucose, not an AI assistant for human interpretation. Therefore, the concept of "effect size of how much human readers improve with AI vs without AI assistance" is not applicable.

    6. If a Standalone (i.e. algorithm only without human-in-the loop performance) Was Done

    The device itself is a standalone diagnostic device; its performance is inherently "algorithm only" in the sense that it measures glucose and provides a numerical output. However, it's not an AI/ML algorithm in the modern sense that often implies learning from data. It's an electrochemical system. The performance studies for such a device would inherently be standalone, evaluating the accuracy and precision of the meter and test strips.

    7. The Type of Ground Truth Used

    While not explicitly stated in this summary, for blood glucose monitoring systems, the ground truth is typically established using a laboratory reference method, such as a YSI glucose analyzer, which is considered the gold standard for glucose measurement in clinical laboratories. This is a form of "objective measurement" or "pathology/reference method" rather than expert consensus or outcomes data.

    8. The Sample Size for the Training Set

    This information is not provided and is largely not applicable in the context of this device. The Prodigy® AutoCode Eject TM Blood Glucose Monitoring System is an electrochemical system, not an AI/ML device that requires a "training set" in the machine learning sense. Its underlying principle is a chemical reaction that generates an electrical current proportional to glucose, not a model trained on data.

    9. How the Ground Truth for the Training Set Was Established

    This information is not provided and is not applicable for the reasons stated above (not an AI/ML device requiring a training set).


    In summary, the provided document describes a traditional in-vitro diagnostic blood glucose meter. The request for information regarding AI/ML-specific study design elements (MRMC, training sets, number of experts, adjudication) is not directly addressed because the device is not an AI/ML medical device. The 510(k) process for such devices focuses on demonstrating substantial equivalence to a legally marketed predicate device by showing similar indications for use, technological characteristics, and comparable safety and effectiveness through "pre-clinical and clinical data" (analytical and clinical performance studies, which are not detailed in this summary).