Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K083408

    Validate with FDA (Live)

    Date Cleared
    2009-07-31

    (255 days)

    Product Code
    Regulation Number
    880.6250
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The powder free chemotherapy examination glove is a specialty medical glove which is a disposable device intended for medical purposes that is worn on the examiner's hand or forefinger to prevent contamination between examiner and patient bodily fluids, waste or environment. Tested for use with chemotherapy drugs. Tested chemotherapy drugs are as follows [Carmustine (BiCNU). Thio-Tepa. Cyclophosphamide, Dacarbazine, Doxorubicin Hydrochloride; 5- Fluorouracil, Cisplatin, Etoposide and Paclitaxel].

    WARNING: DO NOT USE THESE GLOVES WITH THIO-TEPA CAUTION: Testing showed an average breakthrough time of less than 60 minutes with Carmustine.

    Device Description

    Powder Free Blue Nitrile Patient Examination Gloves, Tested for use with Chemotherapy Drugs meet all the requirements of ASTM standard D6978-05, D5712-05e1 and FDA 21 CFR 880.6250.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study information for the "Powder Free Blue Nitrile Patient Examination Gloves, Tested for use with Chemotherapy Drugs," based on the provided 510(k) summary:

    1. Table of Acceptance Criteria and Reported Device Performance

    CharacteristicAcceptance Criteria (Standard)Reported Device Performance
    DimensionsASTM D6319-00aMeets
    Physical PropertiesASTM D6319-00aMeets
    ThicknessASTM D6319-00aMeets
    Powder FreeASTM D6124-01Meets (≤ 2 mg/glove)
    Biocompatibility (Primary Skin Irritation)- (Implied standard)Passes (Not a primary skin irritant)
    Biocompatibility (Dermal Sensitization)ASTM F-720-81Passes (Not a contact sensitizer)
    Watertight (1000ml)ASTM D5151-06Passes
    Resistance to permeation by Chemotherapy DrugsASTM D6978-05Meets requirement

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the specific sample sizes used for each test (dimensions, physical properties, etc.). However, it refers to ASTM standards, which typically outline sampling plans.

    • Data Provenance: The document does not specify the country of origin for the data or whether the studies were retrospective or prospective. It is implied the testing was conducted by the manufacturer (WRP Asia Pacific Sdn Bhd in Malaysia) to meet international standards.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    This information is not applicable to this type of device and study. The "ground truth" for the performance characteristics of examination gloves is established through objective physical and chemical testing against recognized industry standards (e.g., ASTM standards), not through expert consensus or interpretation of medical images/data.

    4. Adjudication Method for the Test Set

    This information is not applicable as there were no subjective assessments requiring adjudication. The tests conducted are objective measurements against predefined criteria.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study was not done. This type of study is typically performed for diagnostic imaging devices where human readers interpret results, often with and without AI assistance. This device is an examination glove, which does not involve human interpretation in the same manner.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Yes, a standalone performance evaluation was conducted. The device (the glove) itself was tested against the various ASTM standards and performance criteria. There is no "algorithm" or "human-in-the-loop" component in the functionality of an examination glove beyond its intended physical properties.

    7. The Type of Ground Truth Used

    The ground truth used for this device's testing is based on objective, standardized measurements and criteria defined by established industry standards (ASTM). For example:

    • Physical measurements (dimensions, thickness)
    • Chemical analysis (powder content)
    • Biocompatibility assays (skin irritation, sensitization)
    • Barrier integrity tests (watertightness, chemotherapy drug permeation)

    8. The Sample Size for the Training Set

    This information is not applicable. This device is not an AI/ML-based system that requires a "training set" in the conventional sense. The manufacturing process and quality control would involve ongoing testing, but there isn't a "training set" like there would be for an algorithmic model.

    9. How the Ground Truth for the Training Set Was Established

    This information is not applicable for the reasons stated in point 8.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1