Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K080036

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2008-01-16

    (9 days)

    Product Code
    Regulation Number
    870.2340
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Portable ECScope 12i hand held, battery operated 12 channel electrocardiograph is intended to be used for the evaluation of the cardiovascular system. Portable ECScope 12i will acquire, record 12 ECG leads simultaneously and display 3 leads in its display unit.

    Portable ECScope 12i is intended to be used by a licensed health care practitioner or under the direct supervision of a licensed health care practitioner in a hospital or health care environment. These measurements are not intended for a specific clinical diagnosis. The clinical significance of the ECG tracings must be determined by the physician in conjunction with clinician's knowledge of patient, the results of physical examination and other clinical findings.

    Device Description

    Portable ECScope 12i is designed to acquire, display and record ECG signals from surface electrodes. The device consists of two basic components: the processing unit and the patient acquisition module.

    Portable ECScope 12i is a multi channel electrocardiograph for the simultaneous acquisition of the 12 ECG leads i.e L1, L2, L3, aVR, aVL, Avf, V1, V2, V3, V4, V5 & V6, featuring 3-lead Display Unit, alphanumeric keyboard and an option to print the ECG data using the Print Tool on A4 Sheet Paper or Direct Printing through connected printer.

    Portable ECScope 12i can record and store in its Database up to 34 ECG tests. Each ECG test can include patient data, doctor's information and ECG measurements. Stored ECG tests can be reviewed and printed on the external printer using a PC.

    AI/ML Overview

    The portable ECScope 12i is designed to acquire, display, and record ECG signals. The device was subjected to safety and performance tests against regulatory standards, and final testing included various performance tests as per ANSI/AAMI EC11:1991 Guidance Document.

    No specific acceptance criteria or reported device performance metrics were provided in the document. The study's purpose was to demonstrate substantial equivalence to predicate devices, not to establish new performance metrics against predefined acceptance criteria. Thus, a table of acceptance criteria and reported device performance cannot be generated from the provided text.

    The document does not describe the specific study that proves the device meets acceptance criteria, beyond stating that "Final testing for the product included various performance tests as per ANSI/AAMI EC11:1991 Guidance Document." There is no detailed information on:

    1. Sample size for the test set and data provenance: Not mentioned.
    2. Number of experts used to establish ground truth and their qualifications: Not mentioned.
    3. Adjudication method for the test set: Not mentioned.
    4. Multi-reader multi-case (MRMC) comparative effectiveness study: Not mentioned.
    5. Standalone (algorithm only) performance: Not mentioned, as this device appears to be a hardware ECG acquisition unit.
    6. Type of ground truth used: Not mentioned.
    7. Sample size for the training set: Not mentioned. This is a hardware device, and the focus of the submission is on physical performance and substantial equivalence rather than AI/algorithm training.
    8. How ground truth for the training set was established: Not mentioned.
    Ask a Question

    Ask a specific question about this device

    K Number
    K072353

    Validate with FDA (Live)

    Device Name
    PORTABLE ECSCOPE
    Manufacturer
    Date Cleared
    2007-08-30

    (8 days)

    Product Code
    Regulation Number
    870.2340
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Portable ECScope handheld, battery operated Multi channel electrocardiograph is intended to be used for evaluation of the cardiovascular system. The Portable ECScope will acquire, display and record Multi channel ECG signals. The Portable ECScope is intended to be used by a licensed health care practitioner or under the direct supervision of a licensed health care practitioner in a hospital or health care environment. These measurements are not intended for specific clinical diagnosis. The clinical significance must be determined by a physician.

    Device Description

    Portable ECScope is a multi channel electrocardiograph for the simultaneous acquisition of the 7 ECG leads i.e L1, L2, L3, aVR, aVL, aVF and one of the chest leads (V1-6), featuring 3-lead Display Unit, alphanumeric keyboard and an option to print the ECG data using the Print Tool on A4 Sheet Paper or Direct Printing through connected printer. Portable ECScope can record and store in its Database up to 200 ECG tests. Each ECG test can include patient data, doctor's information and ECG measurements. Stored ECG tests can be reviewed, printed on the external printer using a PC.

    AI/ML Overview

    The provided text is a 510(k) summary for the Portable ECScope device. It details the device's description, intended use, and comparison to predicate devices. However, it does not contain information about specific acceptance criteria or a study proving the device meets those criteria, as typically found in detailed performance studies for AI/algorithm-based devices.

    The document states:

    "The Portable ECScope was subjected to safety and performance tests against regulatory standards. Final testing for the product included various performance tests as per ANSI/AAMI EC11: 1991 Guidance Document."

    This indicates that the device underwent testing according to a recognized standard for electrocardiographs, but the specific acceptance criteria, test results, and details of how those results were obtained are not included in this summary.

    Therefore, I cannot provide the requested information in the table or the detailed breakdown of study parameters because the provided text does not contain this information.

    If this were an AI or algorithmic device submission, the 510(k) summary would typically include a dedicated section detailing performance data, acceptance criteria, ground truth establishment, and details of the study design. This document is a more traditional medical device submission for an ECG monitor, which relies on demonstrating adherence to established performance standards for hardware and basic functionality, rather than complex algorithmic performance metrics against a clinical ground truth.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1