Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K111018

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2012-02-14

    (308 days)

    Product Code
    Regulation Number
    888.3045
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    OsteoLaso Granule & Strips are intended for use as a bone void filler for voids or gaps that are not intrinsic to the stability of the bony structure. OsteoLaso Granule & Strips are indicated for use in the treatment of surgically created osseous defects or osseous defects resulting from traumatic injury to the bone. OsteoLaso Granule & Strips are intended to be pasked into boney voids or gaps of the skeletal system as a bone void filler (i.e., extremeties, posterolateral spine and pelvis). This product provides a bone void filler that resorbs and is replaced by bone during the healing process.

    Device Description

    OsteoLaso Granule & Strips consists of beta-tricalcium phosphate, and polyphosphate. It is the bone graft substitute that regenerates bone after implantation.

    AI/ML Overview

    This document describes the 510(k) summary for the OsteoLaso Granule & Strips device, a bone void filler. The submission focuses on demonstrating substantial equivalence to a predicate device, Kasios TCP (K042340). As such, it does not detail acceptance criteria or a study proving the device meets those criteria in the way a performance study for a diagnostic or AI device would.

    Instead, the "acceptance criteria" here are essentially the characteristics and properties of the predicate device, which the OsteoLaso device aims to match or exceed to demonstrate equivalence. The "study" is the set of tests performed to compare these characteristics between OsteoLaso and the predicate.

    Here's the information extracted and formatted, keeping in mind the nature of this 510(k) submission:

    1. Table of Acceptance Criteria and the Reported Device Performance

    CharacteristicPredicate Device (Kasios TCP - K042340) Acceptance CriteriaOsteoLaso Granule & Strips Reported PerformanceEquivalence Claim
    BiocompatibilityISO 10993:2003 standardsMeets ISO 10993:2003 standardsEquivalent
    Chemical Composition99.9% Beta-Trichalcium Phosphate (ASTM F1088-87)99.99% Beta-TriCalcium Phosphate (ASTM F1088-87)Equivalent
    Pore Size200-500um200-500umEquivalent
    Percentage of Porosity60-80%Greater than 75%Equivalent
    Indications for UseBone void fillerBone void fillerEquivalent
    Component CharacteristicsPacked with a containerPacked with a containerEquivalent
    Pore InterconnectednessNot explicitly quantified, but claimed equivalentNot explicitly quantified, but claimed equivalentEquivalent

    2. Sample size used for the test set and the data provenance

    The document does not specify sample sizes in terms of a "test set" for clinical data. The tests described are material property tests (biocompatibility, chemical composition, pore size, porosity). The data provenance is related to these material tests, which would be performed in a laboratory setting. There is no mention of country of origin of data, nor whether it is retrospective or prospective clinical data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. This submission concerns material properties and equivalence to a predicate device, not the interpretation of complex data by human experts to establish "ground truth" for a test set in the way a diagnostic AI would require.

    4. Adjudication method for the test set

    Not applicable. There is no mention of an adjudication method as would be used for human expert interpretation of clinical data.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is a bone void filler, not an AI or diagnostic tool. Therefore, an MRMC study and AI assistance are irrelevant to this submission.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    Not applicable. This is not an algorithm or AI device.

    7. The type of ground truth used

    For this type of device, the "ground truth" is established through standardized material testing and established medical knowledge regarding bone void fillers and predicate devices.

    • Biocompatibility: Conformance to ISO 10993:2003 standards.
    • Chemical Composition: Conformance to ASTM F1088-87.
    • Physical Properties (Pore Size, Porosity): Quantitative measurements compared against the predicate's known characteristics.
    • Indications for Use: Comparison of intended uses based on established medical practice and the predicate's existing clearance.

    8. The sample size for the training set

    Not applicable. This device does not involve a "training set" in the context of an AI or machine learning model.

    9. How the ground truth for the training set was established

    Not applicable. As there is no training set, there is no ground truth established for it.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1