Search Filters

Search Results

Found 4 results

510(k) Data Aggregation

    K Number
    K223706

    Validate with FDA (Live)

    Device Name
    PMMA BLOCK
    Date Cleared
    2023-05-12

    (151 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    PMMA BLOCK is used for the fabrication removable or temporary dental structures, such as crowns and bridges using milling technology using CAD/CAM.

    Indications for Use:

    • Temporary anterior and posterior crowns;
    • Temporary anterior and posterior bridges;
    • Removable structures for dentures;
    • Removable structures for therapeutic restorations (night guards, bite splints or occlusal splints).
    Device Description

    PMMA BLOCK is a circular solid (disc) or rectangular solid (block) of PMMA with or without post attachment for use in a CAD/CAM milling machine for production of provisional restorative prostheses such as dental crowns and bridges and removable dental structures. These blocks are available in a variety of shapes for different milling systems and are also available in variety of dental shades.

    AI/ML Overview

    The provided text is a 510(k) Summary for a medical device called "PMMA BLOCK." This document describes the device, its intended use, and compares it to a predicate device to demonstrate substantial equivalence, primarily focusing on physical and chemical properties and biocompatibility.

    Here's an analysis of the provided information concerning acceptance criteria and supporting studies:

    1. A table of acceptance criteria and the reported device performance:
    Acceptance Criteria (ISO Standard)Requirement for Subject Device (PMMA BLOCK)Reported Performance (Subject Device)Reported Performance (Predicate Device K201683)
    Flexural Strength
    ISO 10477$\geq$ 50 MPa$\geq$ 50 MPa$\geq$ 50 MPa
    ISO 20795-1$\geq$ 65 MPa$\geq$ 65 MPa$\geq$ 65 MPa
    Water Absorption
    ISO 10477$\leq$ 0.040 mg/mm³$\leq$ 0.040 mg/mm³$\leq$ 0.040 mg/mm³
    ISO 20795-1$\leq$ 0.032 mg/mm³$\leq$ 0.032 mg/mm³$\leq$ 0.032 mg/mm³
    Water Solubility
    ISO 10477$\leq$ 0.0075 mg/mm³$\leq$ 0.0075 mg/mm³$\leq$ 0.0075 mg/mm³
    ISO 20795-1$\leq$ 0.0016 mg/mm³$\leq$ 0.0016 mg/mm³$\leq$ 0.0016 mg/mm³
    Residual Monomer ContentISO 20795-1: $\leq$ 2.2%$<$ 2.2%$\leq$ 2.2%
    Dimensional StabilityISO 22112: within $\pm$2% of original mesio-distal dimension0.9%0.29%
    BiocompatibilityNon cytotoxic (ISO 10993-5)Non cytotoxicNon cytotoxic
    1. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective):
      The document does not specify the sample sizes used for the physical and chemical properties tests. It also does not explicitly state the country of origin of the test data or whether the studies were retrospective or prospective.

    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience):
      This information is not applicable to the type of device and testing described. The "ground truth" here is defined by international standards (ISO) for material properties. The tests are laboratory-based, measuring quantifiable physical and chemical parameters, not visual interpretations by human experts requiring "ground truth" establishment in a clinical sense.

    3. Adjudication method (e.g., 2+1, 3+1, none) for the test set:
      Not applicable. Adjudication methods like 2+1 or 3+1 are used in clinical studies where expert consensus is needed to establish ground truth for subjective assessments, which is not the case for these material property tests.

    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
      Not applicable. The device is a dental material (PMMA BLOCK), not an AI-assisted diagnostic or therapeutic tool. Therefore, MRMC studies and AI assistance comparisons are not relevant.

    5. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:
      Not applicable. This question typically relates to AI algorithms. The device is a physical material, and its performance is assessed directly through laboratory testing of its physical and chemical properties according to established ISO standards. There is no algorithm involved.

    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
      The "ground truth" for the performance criteria is based on established international standards (ISO standards) for dental materials. These standards define the acceptable range or minimum/maximum values for various physical and chemical properties. The tests are objective measurements against these predefined benchmarks.

    7. The sample size for the training set:
      Not applicable. This device is a physical product, not a machine learning model. Therefore, there is no "training set."

    8. How the ground truth for the training set was established:
      Not applicable, as there is no training set for this type of medical device submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K223477

    Validate with FDA (Live)

    Date Cleared
    2023-02-16

    (90 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is made from PMMA (polymethylmethacrylate) for the fabrication of temporary crowns and bridges and is intended for use in the oral cavity for up to six (6) months while awaiting a permanent restorations are designed and manufactured by a dental Professional (Technician) using CAD technology.

    Device Description

    The PMMA Blocks for Dental Use is a homogeneous high polymer material made from PMMA (polymethylmethacrylate) added with cross-linking agents to improve the network structure through a unique polymerization molding technology. The device is for the fabrication of temporary crowns and bridges and is intended for use in the oral cavity for up to six months while awaiting a permanent restorations are designed and manufactured by a dental professional (such as a dentist) using CAD technology.

    The proposed device contains two models with different shape: Cylinder and Cuboid. There are 39 specifications for Cylinder model (variation in different diameters and heights), and 44 specifications for Cuboid model (variation in different lengths, widths, and heights).

    There are 20 various shades of the proposed device: 1 is transparent (without color added), the other 19 shades are colored (with different coloring matters added). The 19 shades created based on 19 Vita Shades contain A1, A2, A3, A3.5, A4, B1, B2, B3, B4, C1, C2, C3, C4, D2, D3, D4 and OM1,OM2,OM3.

    The PMMA Blocks for Dental Use would be produced on the 39 specifications of Cylinder model or 44 specifications of Cuboid model, with a shade chosen from the 20 various shades.

    The PMMA Blocks for Dental Use is provided as non-sterile.

    AI/ML Overview

    This document describes acceptance criteria and provides results from non-clinical testing of "PMMA Blocks for Dental Use". The document does not contain information about a study that proves the device meets the acceptance criteria, nor does it contain information about clinical studies with human readers or AI.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a table of acceptance criteria with corresponding device performance values against those criteria. Instead, it refers to compliance with international standards for performance and biocompatibility.

    Performance Test Standards:

    Test CategoryStandardAcceptance Criteria (Implied)Reported Device Performance
    Physical/MechanicalISO 10477: 2018 (Dentistry-Polymer-based crown and bridge materials)Compliance with all requirements of ISO 10477: 2018"The test results shown the subject device is fully complied with the requirements of the above standard.""Tested according to ISO 10477"
    Color StabilityISO 7491: 2000 (Dental materials-Determination of color stability)Compliance with all requirements of ISO 7491: 2000Test conducted, results implied to meet standard.
    Shelf Life ValidationASTM F 1980 (Standard Guide for Accelerated Aging of Sterile Medical Device Packages)Maintenance of performance and safety characteristics after accelerated aging for 5 years"The shelf life validation test of the proposed devices was conducted after accelerated aging for 5 years (ASTM F 1980)"
    BiocompatibilityISO 10993-5: 2009 (Cytotoxicity)Non-cytotoxicTest performed, implied to meet standard.
    ISO 10993-10: 2010 (Irritation and Skin Sensitization)Non-irritating, non-sensitizingTest performed, implied to meet standard.
    ISO 10993-11: 2017 (Systemic Toxicity)No systemic toxic effectsTest performed, implied to meet standard.
    ISO 10993-6: 2016 (Local Effects after Implantation)No adverse local effectsTest performed, implied to meet standard.
    ISO 10993-3 (Genotoxicity, Carcinogenicity and Reproductive Toxicity)Non-genotoxic, non-carcinogenic, no reproductive toxicityTest performed, implied to meet standard.
    ISO 10993-1:2018, FDA Guidance (General Biocompatibility)Compliance with general biocompatibility requirements"Comply with ISO 10993-1:2018, FDA Guidance, tests included cytotoxicity, oral mucosa irritation, skin sensitization, Subchronic systemic toxicity, genotoxicity, Acute Systemic Toxicity and Pyrogens."

    2. Sample Size Used for the Test Set and Data Provenance

    The document describes non-clinical testing of a dental material. Information regarding "sample size used for the test set" typically refers to the number of individual test specimens or batches tested for each specific test mentioned (e.g., number of specimens for flexural strength, number of samples for cytotoxicity assay). However, this specific detail (the exact number of specimens per test) is not provided in the document.

    Data provenance (country of origin, retrospective/prospective) is not applicable in the context of this non-clinical, in-vitro/materials testing. The tests are laboratory-based and performed on the device material itself, not on patient data.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not applicable as the document describes non-clinical material testing, not human-reviewed data where "ground truth" would be established by experts.

    4. Adjudication Method for the Test Set

    This information is not applicable as the document describes non-clinical material testing, not a study involving human interpretation or adjudication.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    An MRMC comparative effectiveness study was not done. The document focuses on the non-clinical performance and biocompatibility of a dental material, not on the effectiveness of human readers or AI assistance.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    A standalone algorithm performance study was not done. The device is a material, not a software algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    This information is not applicable as the document pertains to non-clinical material testing, where "ground truth" is typically defined by scientific measurement against established standards (e.g., specific chemical composition, physical properties, or biological reactions measured in a lab setting), rather than clinical interpretation or outcomes.

    8. The sample size for the training set

    This information is not applicable. The document describes the testing of a physical medical device (PMMA Blocks), not an AI algorithm that would require a training set.

    9. How the ground truth for the training set was established

    This information is not applicable. As in point 8, there is no training set mentioned or implied in this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201683

    Validate with FDA (Live)

    Device Name
    PMMA Block
    Date Cleared
    2020-11-03

    (134 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    PMMA BLOCK particularly suitable for making removable or temporary dental structures such as crowns and bridges using milling technology using CAD/CAM.

    Indications for Use:

    • Temporary anterior and posterior crowns;
    • Temporary anterior and posterior bridges;
    • Implant surgical guide;
    • Removable structures for dentures;
    • Removable structures for therapeutic restorations (night guards, bite splints or occlusal splints).
    Device Description

    PMMA BLOCK is a circular solid (disc) or rectangular solid (block) of PMMA with or without post attachment for use in a CAD/CAM milling machine for production of provisional restorative prostheses such as dental crowns and bridges and removable dental structures. These blocks are available in a variety of shapes for different milling systems and are also available in variety of dental shades.

    PMMA BLOCK are made with the same material (Hot cured PMMA) that is used for the manufacture of the HUGE Synthetic Polymer Teeth (K101029) and HUGE PMMA Block(K141421). These polymer discs or blocks are especially suited for creating dental structures by means of milling CAD/CAM techniques commonly used in the dental laboratories and in dental practice. The elaboration is designed by a professional, a dental technician or a dentist. This guarantees their correct use, since it is an intermediate product in order to manufacture a custom-made product.

    AI/ML Overview

    The provided text is a 510(k) summary for the PMMA Block, a dental material. It outlines the device's characteristics and compares it to predicate devices to establish substantial equivalence.

    However, the document does not contain any information about a study proving the device meets acceptance criteria related to AI or machine learning performance. The "acceptance criteria" discussed in the document pertain to the physical and chemical properties of the PMMA Block and its compliance with ISO standards for dental materials.

    Therefore, I cannot provide the requested information regarding:

    • A table of acceptance criteria for AI performance and reported device performance.
    • Sample sizes, data provenance, number of experts for ground truth, adjudication methods for a test set.
    • Multi-reader multi-case (MRMC) comparative effectiveness studies or standalone algorithm performance.
    • Type of ground truth used related to AI.
    • Training set sample size or how ground truth for training was established.

    The document focuses on the material's properties, chemical composition, and manufacturing process, asserting substantial equivalence to existing dental materials, not on the performance of an AI-powered device.

    Summary of relevant information from the document (not directly answering the AI-related questions):

    • Device: PMMA Block (dental polymer blanks)
    • Purpose: For making removable or temporary dental structures (crowns, bridges, surgical guides, dentures, night guards/bite splints) using CAD/CAM milling.
    • Study Type: This is a 510(k) premarket notification based on substantial equivalence to predicate devices, not a clinical performance study of a novel AI or medical imaging device.
    • "Acceptance Criteria" presented: Primarily physical and chemical properties of the material, tested against ISO standards (ISO 10477, ISO 20795-1, ISO 22112).
      • Flexural strength: The new device must meet $\ge$ 50 MPa (ISO 10477) and $\ge$ 65 MPa (ISO 20795-1).
      • Water absorption: The new device must meet $\le$ 0.040 mg/mm³ (ISO 10477) and $\le$ 0.032 mg/mm³ (ISO 20795-1).
      • Water solubility: The new device must meet $\le$ 0.0075 mg/mm³ (ISO 10477) and $\le$ 0.0016 mg/mm³ (ISO 20795-1).
      • Residual monomer content: The new device must meet $\le$ 2.2% (ISO 20795-1).
      • Dimensional stability: The new device must meet within $\pm$ 2% of original mesio-distal dimension (ISO 22112).
    • Reported Device Performance (from Table 4):
      • Flexural strength: $\ge$ 50 MPa and $\ge$ 65 MPa (meeting the criteria).
      • Water absorption: $\le$ 0.040 mg/mm³ and $\le$ 0.032 mg/mm³ (meeting the criteria).
      • Water solubility: $\le$ 0.0075 mg/mm³ and $\le$ 0.0016 mg/mm³ (meeting the criteria).
      • Residual monomer content: $\le$ 2.2% (meeting the criteria).
      • Dimensional stability: 0.29% (meeting the criteria of $\pm$ 2%).
    • Biocompatibility: Tests were performed according to ISO 10993 standards (Systemic Toxicity, Irritation, Sensitization, Cytotoxicity, In Vitro Mammalian Cell TK Gene Mutation Test, In Vitro mammalian chromosome aberration test, and Bacterial reverse mutation study). The document states the device is "Non cytotoxic."
    • Clinical Performance Data: "Not applicable. Clinical performance testing has not been performed for the subject device." (Section 10).
    Ask a Question

    Ask a specific question about this device

    K Number
    K141421

    Validate with FDA (Live)

    Device Name
    PMMA BLOCK
    Date Cleared
    2015-02-09

    (255 days)

    Product Code
    Regulation Number
    872.3770
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    PMMA Block is a device made from PMMA (polymethylmethacrylate) for the fabrication of temporary crowns and bridges and is intended for use in the oral cavity for up to six (6) months while awaiting a permanent restorations are designed and manufactured by a dental Professional (Technician) using CAD technology.

    Device Description

    This product is a kind of homogeneous high polymer material made from quality polymethylmethacrylate added with cross-linking agents to improve the network structure through a unique polymerization molding technology. It is mainly used for the fabrication of multi-unit, fully or partially anatomical long-term temporary bridge restorations with up to two pontics by CAD/CAM systems. Both anterior and posterior crown & bridge are recommended.

    AI/ML Overview

    This document describes the premarket notification (510(k)) for the PMMA Block, a device used for fabricating temporary crowns and bridges. The information provided focuses on demonstrating substantial equivalence to a predicate device, rather than a standalone study proving the device meets specific acceptance criteria based on human-in-the-loop performance or clinical outcomes.

    Here's an analysis based on the provided text, addressing your questions where information is available:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are primarily defined by ISO standards and comparison to a predicate device.

    Acceptance Criterion (Set by Standards/Predicate)Reported Device Performance (PMMA Block)
    Intended Use (Same as predicate)A device made from PMMA for the fabrication of temporary crowns and bridges and is intended for use in the oral cavity for up to six (6) months while awaiting a permanent restoration. Restorations are designed and manufactured by a dental Professional (Technician) using CAD technology.
    Material of Construction (Same as predicate)PMMA
    Shades (Comparable to predicate)20 Vita Shades
    Processing Method (Same as predicate)Variable Thickness Milling Blank and machined using any milling system
    Flexural Strength (According to ISO 10477, implied)≥50 MPA (Predicate: 113 MPA)
    Shelf-life (For information, not a direct acceptance criterion for equivalence)Five Years
    Performance Effectiveness (Tested according to ISO 10477)Tested according to ISO 10477. "Its results show that the subject device fully meets the requirement..." (Specific numerical results beyond flexural strength not detailed in this summary).
    Performance Safety (Tested according to ISO 10993 standards)Tested according to ISO 10993 standards.
    Biocompatibility (According to AAMI / ANSI / ISO 10993 standards)Tested according to AAMI / ANSI / ISO 10993-3, 10993-5, 10993-10, and 10993-11.
    Physical Property Testing (Includes flexural strength, surface polishing performance, bond strength, water sorption, solubility, shade consistency, color stability as per ISO 10477)"The test results... show that the subject device fully meets the requirement..." (Specific values beyond flexural strength not provided in this summary).

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: The document does not specify a "test set" in the context of clinical studies with patient data. The testing was non-clinical, primarily physical property and biocompatibility tests. The sample size for these non-clinical tests is not provided in this summary.
    • Data Provenance: The data is from non-clinical laboratory testing (physical, chemical, and biological) conducted by Rizhao Huge Dental Industry Co., Ltd. The country of origin for the data generation would be China, where the manufacturer is located. The nature of these tests is not "retrospective" or "prospective" in the typical clinical sense, but rather laboratory evaluations.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not applicable. Ground truth, in the context of clinical studies, refers to a definitive diagnosis or outcome. For this device, the "ground truth" for non-clinical testing is adherence to established international standards (ISO, AAMI/ANSI/ISO). Expert consensus for ground truth is not relevant for this type of submission.

    4. Adjudication Method for the Test Set

    This information is not applicable. Adjudication methods (e.g., 2+1) are used in clinical studies to resolve discrepancies among expert readers. Since this submission relies on non-clinical testing against standards and comparison to a predicate, such methods are not relevant.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance

    This information is not applicable. The PMMA Block is a material for dental restorations, not an AI-powered diagnostic or assistive device for human readers. Therefore, an MRMC study with AI assistance is not relevant to this submission.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    This information is not applicable. The PMMA Block is a physical product (material) and not an algorithm.

    7. The Type of Ground Truth Used

    The "ground truth" used for this submission is adherence to international standards for dental materials (ISO 10477) and biocompatibility (ISO 10993 series), and demonstration of comparable characteristics to a legally marketed predicate device. There is no clinical "ground truth" data (like pathology or outcomes data) presented in this 510(k) summary.

    8. The Sample Size for the Training Set

    This information is not applicable. There is no AI component involved, and thus no "training set" in the context of machine learning.

    9. How the Ground Truth for the Training Set Was Established

    This information is not applicable, as there is no training set for an AI algorithm.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1