510(k) Data Aggregation

    K Number
    K190754

    Validate with FDA (Live)

    Device Name
    Orthoss(R)
    Date Cleared
    2019-06-23

    (90 days)

    Product Code
    Regulation Number
    888.3045
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ORTHOSS® is an implant intended to fill bony voids or gaps of the skeletal system (i.e. extremities, posterolateral spine and pelvis). ORTHOSS® can be used with autograft as a bone graft extender in a posterolateral spine fusion. These osseous defects may be surgically created or be the result of traumatic injury to the bone and are not intrinsic to the stability of the bony structure. The device resorbs and is replaced with bone during the healing process.

    Device Description

    Orthoss® is an inorganic bone matrix, manufactured from bovine bone, with an interconnected macro- and microporous structure that supports the formation and ingrowth of new bone. Over time, Orthoss® is partially remodeled by osteoclasts (physiological remodeling). The single-use product is provided sterile (via gamma irradiation) in block (1 x 1 x 2 cm and 2 x 2 x 1.3 cm) or granular (1 - 2 mm and 2 - 4 mm) form in double-blister packs or glass vials in a blister pack, respectively.

    AI/ML Overview

    This document discusses the 510(k) premarket notification for Orthoss®, a resorbable calcium salt bone void filler. It describes the device, its indications for use, comparison to a predicate device, and performance data provided to support its substantial equivalence.

    Here's an analysis to extract the requested information:

    Analysis of the document for Acceptance Criteria and Study Details:

    The document describes a medical device (Orthoss®), not an AI/software device. Therefore, the questions related to AI performance metrics (e.g., human reader improvement with AI, standalone AI performance, training set details, expert ground truth establishment for AI) are not applicable to this submission.

    The "acceptance criteria" for this device are primarily demonstrated through substantially equivalent (SE) determination to a predicate device, supported by performance data demonstrating safety and effectiveness. The "study that proves the device meets the acceptance criteria" refers to the non-clinical performance studies, particularly an animal study for an extended indication.

    1. A table of acceptance criteria and the reported device performance:

    Since this is not an AI device, there isn't a table of statistical performance metrics like sensitivity/specificity for disease detection. Instead, "acceptance criteria" are implied by the demonstration of substantial equivalence across various aspects.

    Acceptance Criteria (Implied for SE)Reported Device Performance
    Material Characteristics, Manufacturing, Sterilization, Packaging, Size: Similar to predicate device.The subject device is similar to the predicate device with respect to materials characteristics, manufacturing and sterilization methods, packaging, and size. Both the subject and predicate device have identical final product specifications. (Page 4) Minor changes (vial cap, manufacturing processes, raw material supplier, filling volume, packaging) did not raise different questions of safety and effectiveness. (Page 4)
    Safety: Biocompatibility, non-pyrogenic, endotoxin levels.Biocompatibility per ISO 10993-1:2018 (Page 4) Pyrogenicity per USP <151> and endotoxin per USP <85> (Page 4)
    Shelf-life stability: Demonstrated stability over time.Shelf-life studies per ICH Q1A (R2) (Page 4)
    Performance for Extended Indication (Autograft Extender): Similar performance to predicate and positive control in bone healing, resorption, and fusion.Animal Study Results (Boden Rabbit Spinal Fusion Model): (Page 5) - Radiographic Appearance: Subject and predicate device performed similarly. - Micro-computed Tomography: Subject and predicate device performed similarly; evidence of new bone formation, resorption, and remodeling observed. - Histology: Normal patterns of bone healing in test group, similar to predicate group and positive control (autograft). New bone formation and bone remodeling occurred over time. Presence of some inflammatory cells as devices degraded. - Manual Palpation: No differences in distribution of findings between subject and predicate groups. - Multidirectional Flexibility: Similar for subject and predicate devices. - Adverse Events: No adverse events or device-related failures noted during harvesting. - Positive Control: Performance consistent with published data/study site experience.
    Sterilization Assurance: Validated sterilization process.Sterilization validation per ISO 11137-1:2006, ISO 11137-2:2013, and ISO 11137-3:2017 (Page 4)
    Packaging Integrity: Validated packaging.Packaging validation per ISO 11607-1:2009/ Amd 2014 and ISO 11607-2:2006/ Amd 2014 (Page 4)
    Material Characterization: Chemical and structural properties confirmed.X-ray, Fourier Transform Infrared, and HG-Pressure Porosimetry analysis (Page 4)

    2. Sample size used for the test set and the data provenance:

    • Test Set Description: The "test set" here refers to the animal study conducted to support the extended indication.
    • Sample Size: The document states "Rabbits were randomized to receive Orthoss®, MASTERGRAFT® Resorbable Ceramic Granules, or autograft control." (Page 5). It does not specify the exact number of rabbits in each group or overall.
    • Data Provenance: The study used a "validated Boden rabbit spinal fusion model." (Page 5). This is a prospective animal study. The country of origin of the data is not explicitly stated but implies a controlled laboratory setting.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • This question is Not Applicable in the context of this device. The ground truth for the animal study (bone healing, fusion, etc.) was established through direct observation, radiographic analysis, micro-computed tomography, and histological analysis of the animal tissue, not by human expert readers interpreting images for disease diagnosis. The evaluation was primarily objective measurements and pathological assessment.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • Not Applicable. As this is an animal study involving direct biological and imaging measurements (radiographs, micro-CT, histology, manual palpation), there is no mention of "adjudication" in the sense of multiple human readers resolving disagreements on interpretations. The results were based on direct observation and analysis by the researchers and pathologists involved in the study.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not Applicable. This is a medical device (bone void filler), not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not Applicable. This is a physical medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • For the animal study: The ground truth was established through a combination of:
      • Radiographic appearance (direct imaging evidence)
      • Micro-computed tomography (detailed 3D imaging of bone structure)
      • Histology (microscopic examination of tissue, considered the gold standard for bone formation and remodeling)
      • Manual palpation (a physical assessment of fusion rigor)
      • Multidirectional flexibility measurements of the spine.

    8. The sample size for the training set:

    • Not Applicable. This is not an AI/machine learning device that requires a "training set."

    9. How the ground truth for the training set was established:

    • Not Applicable. No training set was involved.
    Ask a Question

    Ask a specific question about this device

    K Number
    K090401

    Validate with FDA (Live)

    Device Name
    ORTHOSS
    Date Cleared
    2010-01-08

    (325 days)

    Product Code
    Regulation Number
    888.3045
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ORTHOSS® Resorbable Bone Void Filler is indicated for bony voids or gaps of the skeletal system (i.e. the extremities, spine and pelvis). ORTHOSS® is indicated only for use in bone voids or gaps that are not intrinsic to the stability of the bony structure. These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone. ORTHOSS® Resorbable Bone Void Filler is intended to be used in the spine only for posterolateral fusion.

    Device Description

    ORTHOSS® is a natural non-antigenic, porous bone mineral. It is produced by removal of all organic components from bovine bone. Due to its natural structure, it is physically and chemically comparable to the mineralized matrix of human bone.

    AI/ML Overview

    This document, a 510(k) summary for ORTHOSS® Resorbable Bone Void Filler, does not contain any information regarding acceptance criteria or a study proving the device meets those criteria.

    The document primarily focuses on establishing substantial equivalence to previously cleared devices. It states that:

    • The only change from the previously cleared ORTHOSS® product (K01-4289) is the source of the bovine bone, which has shifted from the U.S. to Australia.
    • Australia is considered a low-risk country for BSE, and this change in source is deemed not to negatively impact the safety of the product.

    Therefore, I cannot provide the requested information. The 510(k) process for this specific device relied on demonstrating that the new version is substantially equivalent to a previously approved device, rather than presenting new performance data against acceptance criteria.

    Ask a Question

    Ask a specific question about this device

    K Number
    K014289

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2002-03-28

    (90 days)

    Product Code
    Regulation Number
    872.3930
    Panel
    Dental
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ORTHOSS is indicated for bony voids or gaps of the skeletal system (i.e. the extremities, spine and pelvis). ORTHOSS is indicated only for use in bone voids or gaps that are not intrinsic to the stability of the bony structure. These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone.

    Device Description

    ORTHOSS™ Resorbable Bone Void Filler

    AI/ML Overview

    The provided document is a 510(k) clearance letter from the FDA for a medical device called ORTHOSS™ Resorbable Bone Void Filler. This type of letter indicates that the device has been found substantially equivalent to a legally marketed predicate device, and it does not contain the detailed information about acceptance criteria or a specific study proving the device meets those criteria in the way a clinical study report would.

    Therefore, for the acceptance criteria and study details you requested, the document states:

    1. A table of acceptance criteria and the reported device performance: This information is not present in the 510(k) clearance letter. The letter confirms substantial equivalence, which means the device is as safe and effective as a predicate device, but it doesn't detail specific performance metrics against pre-defined acceptance criteria from a study.
    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective): This information is not provided in the 510(k) clearance letter.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience): This information is not provided in the 510(k) clearance letter.
    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set: This information is not provided in the 510(k) clearance letter.
    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: This device is a bone void filler, not an AI diagnostic tool. Therefore, an MRMC study comparing human readers with and without AI assistance is not applicable to this product.
    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done: As this is a bone void filler and not a diagnostic algorithm, this concept is not applicable.
    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): This information is not provided in the 510(k) clearance letter.
    8. The sample size for the training set: This information is not provided in the 510(k) clearance letter.
    9. How the ground truth for the training set was established: This information is not provided in the 510(k) clearance letter.

    In summary: The provided document is a regulatory clearance letter focused on substantial equivalence to a predicate device. It does not contain the detailed study design, acceptance criteria, or performance data that would be found in a clinical study report or a pre-market approval (PMA) application for a novel, high-risk device. The assessment for a 510(k) clearance primarily involves demonstrating that the new device is as safe and effective as devices already on the market, often through comparison of technological characteristics, materials, and intended use, rather than a full-scale clinical trial with pre-defined acceptance criteria and reported device performance.