510(k) Data Aggregation

    K Number
    K231926

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-03-22

    (266 days)

    Product Code
    Regulation Number
    882.5805
    Age Range
    All
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    NeuroStar Advanced Therapy is indicated as an adjunct for the treatment of Major Depressive Disorder (MDD) in adolescent patients (age 15-21).

    Device Description

    The NeuroStar Advanced Therapy System is a transcranial magnetic stimulation device. Specifically, it is a computerized, electromechanical medical device that produces and delivers non-invasive magnetic fields to induce electrical currents targeting specific regions of the cerebral cortex. Transcranial magnetic stimulation (TMS) is a non-invasive technique used to apply brief magnetic pulses to the brain. The pulses are administered by passing high currents through an electromagnetic coil placed adjacent to a patient's scalp. The pulses induce an electric field in the underlying brain tissue. When the induced field is above a certain threshold and is directed in an appropriate orientation relative the brain's neuronal pathway, localized axonal depolarizations are produced, thus activating neurons in the targeted brain region.

    The NeuroStar System consists of a combination of hardware, disposable, and consumable supplies, which are required for the operation of the system. The basic configuration includes the following components:

    • Mobile Console
    • System Software
    • Treatment Chair
    • Head Support System
    • MT Cap
    • . D-Tect MT Accessory
    • TrakStar Data Management
    AI/ML Overview

    The NeuroStar Advanced Therapy System is indicated as an adjunct for the treatment of Major Depressive Disorder (MDD) in adolescent patients (age 15-21).

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Success Criteria)Reported Device Performance
    A minimum of 50% of the primary per protocol analysis population meet the Individual Subject Success Criteria (defined as a meaningful reduction in depression symptoms based on PHQ-9 scores over a pre-post TMS treatment interval of 6 weeks and achieving remission of MDD symptoms).77.8% (95% CI: 72.8%, 83.0%) of the primary per protocol population met the criteria.
    The lower limit of the 95% confidence interval for individual success rate should exceed the pre-established Overall Study Success Criteria of a minimum 50%.The lower limit (72.8%) exceeded 50% by 22.79%.
    Proportion of responders (defined as a meaningful reduction in depression symptoms based on PHQ-9 scores) is statistically significant.This proportion was found to be statistically significant at p < 0.0001.
    Mean change in PHQ-9 scores from baseline to endpoint is statistically significant.The mean change in PHQ-9 scores from baseline to endpoint was -10.0 ± 6.6 (indicating improvement).
    30% or more patients attain remission of MDD symptoms (defined as post-treatment PHQ-9 of <5).30.0% attained remission of MDD symptoms.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size (Test Set): 1,169 per protocol adolescent patients (age 12-21) were included in the real-world data analysis.
    • Data Provenance: The data was retrospective real-world data (RWD) derived from the TrakStar registry, collected from patients across 347 TMS centers in the US over a span of 15 years, beginning in 2008.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    The document does not explicitly state the number of experts used to establish ground truth or their qualifications for the test set derived from the TrakStar registry. The clinical data was based on real-world data (RWD) which would imply physician diagnoses and assessments during routine clinical care, not necessarily a separate expert panel for ground truth within the study itself.

    4. Adjudication Method for the Test Set

    The document does not specify an adjudication method like 2+1 or 3+1 for the test set. The data was collected from clinical practice (TrakStar registry) and analyzed retrospectively.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No multi-reader multi-case (MRMC) comparative effectiveness study was mentioned where human readers improved with AI vs. without AI assistance. The study focuses on the effectiveness of the NeuroStar Advanced Therapy System itself, not on an AI-assisted diagnostic tool for human readers.

    6. Standalone (Algorithm Only) Performance Study

    The NeuroStar Advanced Therapy System is a medical device that delivers transcranial magnetic stimulation, not a standalone algorithm. Therefore, a standalone (algorithm only) performance study as typically understood for AI/ML devices, was not performed. The performance data relates to the device's clinical efficacy in treating MDD.

    7. Type of Ground Truth Used

    The ground truth for the real-world data analysis was based on clinical diagnosis of Major Depressive Disorder (MDD) according to DSM-4/ICD-9 or DSM-5/ICD-19 criteria, and Patient Health Questionnaire-9 (PHQ-9) scores for depression severity and remission, collected as part of routine clinical care and stored in the TrakStar registry.

    8. Sample Size for the Training Set

    The document does not explicitly mention a "training set" in the context of an AI/ML algorithm that requires training. The device itself is a non-AI medical device; however, the submission uses real-world clinical data and literature reviews to support its expanded indication. If "training set" refers to the data used to initially establish the device's efficacy, the previous FDA clearances (K083538, K130233, etc.) would have involved their own clinical studies. For this specific expanded indication, the submission relies on the large-scale retrospective analysis of 1,169 adolescent patients (treated with the NeuroStar device in real-world settings) and a literature review of 14 studies involving a total of 1,812 adolescents.

    9. How the Ground Truth for the Training Set Was Established

    As noted in point 8, this is not an AI/ML algorithm requiring a "training set" in the typical sense. The "ground truth" for the real-world data analysis and literature review, which serve as evidence for device efficacy, was established through:

    • Clinical Diagnoses: Primary diagnosis of MDD according to DSM-4/ICD-9 or DSM-5/ICD-19 criteria.
    • Validated Clinical Scales: Assessment using standardized and validated depression scales such as PHQ-9, HAMD-24, HAM-D, CDRS-R, QIDS-A17-SR, CGI-S, HDRS-17, BDI-II, MADRS, BPRS-C, and CGAS. These scores represent objective measures of symptom severity and improvement, as reported in clinical practice and research studies.
    • Physician Assessment: The inclusion criteria for the RWD study specified "Primary diagnosis of Major Depressive Disorder (MDD), according to DSM-4/ICD-9 or DSM-5/ICD-19 criteria applicable on the date treatment with NeuroStar Advanced Therapy begins," indicating physician-based diagnosis.
    Ask a Question

    Ask a specific question about this device

    K Number
    K233621

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-12-13

    (30 days)

    Product Code
    Regulation Number
    882.5805
    Age Range
    18 - 120
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NeuroStar Advanced Therapy System is indicated for the treatment of depressive episodes and for decreasing anxiety symptoms for those who may exhibit comorbid anxiety symptoms in adult patients suffering from Major Depressive Disorder (MDD) and who failed to achieve satisfactory improvement from previous antidepressant medication treatment in the current episode.

    The NeuroStar Advanced Therapy system is intended to be used as an adjunct for the treatment of adult patients suffering from Obsessive-Compulsive Disorder (OCD).

    Device Description

    The NeuroStar Advanced Therapy System is a transcranial magnetic stimulation device. Specifically, it is a computerized, electromechanical medical device that produces and delivers non-invasive magnetic fields to induce electrical currents targeting specific regions of the cerebral cortex. Transcranial magnetic stimulation (TMS) is a non-invasive technique used to apply brief magnetic pulses to the brain. The pulses are administered by passing high currents through an electromagnetic coil placed adjacent to a patient's scalp. The pulses induce an electric field in the underlying brain tissue. When the induced field is above a certain threshold and is directed in an appropriate orientation relative the brain's neuronal pathway, localized axonal depolarizations are produced, thus activating neurons in the targeted brain region.

    The NeuroStar Advanced Therapy System is an integrated system consisting of a combination of the following components:

    • Mobile Console
    • System Software
    • Treatment Chair
    • Ferromagnetic Treatment Coil
    • Head Support System or Headrest
    • SenStar® Connect Treatment Link & SenStar® Treatment Link
    • Treatment Pack (for use with the SenStar® Connect Treatment Link)
    • MDD MT Cap and OCD MT Cap
    • TrakStar™ Patient Data Management System
    • D-Tect™ MT Accessory
    • NeuroSITE
    AI/ML Overview

    The provided document is a 510(k) summary for the NeuroStar Advanced Therapy System (Version 3.8). This document primarily focuses on demonstrating substantial equivalence to predicate devices for regulatory clearance, rather than detailing clinical study results or acceptance criteria in the comprehensive manner typically found in a clinical study report for an AI/ML device.

    However, based on the information provided, we can infer some details relevant to your request, specifically concerning the engineering and human factors testing which serves as the "study" proving the device meets performance criteria, even if not phrased as traditional "acceptance criteria" for an AI/ML algorithm's clinical performance.

    Here's an attempt to answer your questions based on the available text:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state quantitative acceptance criteria for the performance of the new software features, nor does it present device performance in a table with specific metrics. Instead, it states a qualitative conclusion:

    Acceptance Criterion (Inferred)Reported Device Performance
    Successful recording, saving, and displaying of patient's MT and treatment locations by NeuroSITE and Headrest (equivalent to current Head Support System)."the results of verification and validation testing confirmed that the NeuroSITE and Headrest can successfully be used with the NeuroStar System software to record, save, and display the patient's MT and treatment locations in a manner that is equivalent to the current Head Support System."
    Treatment location equivalence between new components (NeuroSITE/Headrest) and current Head Support System."Engineering and Human Factors testing had demonstrated that the treatment location is equivalent whether using the Head Support System or the NeuroSITE" (stated for both MDD and OCD indications).
    Clinical outcomes will be the same with new components."and clinical outcomes will be the same" (stated for both MDD and OCD indications, though this is a prediction based on location equivalence, not a direct clinical outcome measure from this specific submission's testing).

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document mentions "verification and validation testing" and "Engineering and Human Factors testing." It does not specify the sample size (e.g., number of uses, number of subjects for human factors) used for these tests. It also does not provide details on data provenance (country of origin, retrospective/prospective). This type of detail is typically found in the full test reports, which are summarized in the 510(k).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    The document does not provide information on the number or qualifications of experts used to establish "ground truth" for the engineering and human factors testing. Given the nature of the change (replacement of physical components for coil positioning), the ground truth for "treatment location equivalence" would likely be based on physical measurements and possibly user observations in human factors studies, rather than expert interpretation of medical images.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    The document does not describe any adjudication method. This type of process is common in image interpretation studies or clinical trials where subjective assessments are made by multiple readers. For engineering and human factors testing of device mechanics and software functionality, adjudication in this sense is typically not applicable.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC comparative effectiveness study was done or mentioned. This submission is for a modification to a Transcranial Magnetic Stimulation (TMS) system, specifically regarding mechanical components and software for coil positioning, not an AI-assisted diagnostic or interpretative device that would typically undergo an MRMC study. The device itself is a treatment device, not primarily an AI-driven interpretive one in the context of MRMC studies.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The document does not detail separate standalone algorithm performance. The software change (version 3.8) is explicitly linked to the physical components (NeuroSITE and Headrest) for recording, saving, and displaying patient MT and treatment locations. The testing confirmed the system's ability (software with new hardware) to achieve equivalence, implying an integrated performance evaluation rather than a standalone algorithm assessment.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The document doesn't explicitly state the "type of ground truth." However, based on the context of the device modification (coil positioning), the ground truth for "treatment location equivalence" would most likely be established through:

    • Engineering measurements: Precise physical measurements of coil placement relative to anatomical landmarks.
    • Human factors evaluation: Observation and measurement of user interaction and accuracy in achieving desired coil positions by operators, potentially against a pre-defined target or the performance of the predicate system.
    • Absence of new risks: The document emphasizes that the change "does not introduce any new risks" and that "clinical outcomes will be the same," implying that the ground truth for safety and effectiveness is tied to maintaining the established performance of the predicate device.

    8. The sample size for the training set

    The document does not mention a training set, as this submission is for a hardware and software update to an existing device, not the development or retraining of a new AI/ML algorithm where large training datasets are typically disclosed. The software updates are likely based on engineering design and software development best practices, rather than AI model training.

    9. How the ground truth for the training set was established

    As no training set is mentioned in the context of AI/ML, this question is not applicable to the information provided. The "ground truth" for the software's functionality would have been established through software requirements, design specifications, and subsequent verification and validation testing against these pre-defined expectations.

    Summary of what the document focuses on regarding "proof":

    The core of the "proof" in this 510(k) submission, regarding the software and hardware changes, is the demonstration through non-clinical testing (engineering and human factors) that the new components perform equivalently to the existing ones in terms of their intended functions, specifically "recording, saving, and displaying the patient's MT and treatment locations" and achieving "treatment location equivalence." The conclusion is that these changes do not introduce new questions of safety or effectiveness. This is a common approach for minor device modifications where clinical performance has already been established by the predicate device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K230029

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-04-04

    (90 days)

    Product Code
    Regulation Number
    882.5805
    Age Range
    All
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NeuroStar Advanced Therapy System is indicated for the treatment of depressive episodes and for decreasing anxiety symptoms for those who may exhibit comorbid anxiety symptoms in adult patients suffering from Major Depressive Disorder (MDD) and who failed to achieve satisfactory improvement from previous antidepressant medication treatment in the current episode.

    The NeuroStar Advanced Therapy system is intended to be used as an adjunct for the treatment of adult patients suffering from Obsessive-Compulsive Disorder (OCD).

    Device Description

    The NeuroStar Advanced Therapy System is a transcranial magnetic stimulation device. Specifically, it is a computerized, electromechanical medical device that produces and delivers non-invasive magnetic fields to induce electrical currents targeting specific regions of the cerebral cortex. Transcranial magnetic stimulation (TMS) is a non-invasive technique used to apply brief magnetic pulses to the brain. The pulses are administered by passing high currents through an electromagnetic coil placed adjacent to a patient's scalp. The pulses induce an electric field in the underlying brain tissue. When the induced field is above a certain threshold and is directed in an appropriate orientation relative the brain's neuronal pathway, localized axonal depolarizations are produced, thus activating neurons in the targeted brain region.

    The NeuroStar Advanced Therapy System is an integrated system consisting of a combination of the following components:

    • Mobile Console
    • System Software
    • Treatment Chair
    • Ferromagnetic Treatment Coil
    • Head Support System
    • SenStar® Connect Treatment Link & SenStar® Treatment Link
    • Treatment Pack (for use with the SenStar® Connect Treatment Link)
    • MT Cap
    • TrakStar™ Patient Data Management System
    • D-Tect™ MT Accessory
    • Beam F3 Treatment Pack

    There are two proposed changes to the NeuroStar Advanced Therapy System that are the subject of this 510(k). The first proposed change introduces the capability to use wireless communication to transfer data between the NeuroStar System software and the TrakStar Patient Data Management System, as an alternative to using an ethernet cable to facilitate this transfer. The second proposed change allows for the alternative use of the Beam F3 treatment location method (herein: "Beam F3 method"), in addition to the current method that utilizes a location 5 cm away from the motor threshold within the dorsolateral prefrontal cortex (DLPFC) reqion of the brain. The Beam F3 method requires measuring different skull dimensions and uses these values to calculate the F3 treatment location, which is also located within the DLPFC. This 510(k) introduces software embedded into the NeuroStar System that performs these calculations as well as single-use measuring accessories. Once the F3 treatment location is determined, the treatment parameters and protocols remain the same as those used in the currently marketed NeuroStar Advanced Therapy System.

    AI/ML Overview

    This document does not contain an acceptance criteria table or a detailed study proving the device meets specific performance criteria through clinical testing. Instead, it is a 510(k) premarket notification summary from the FDA, asserting substantial equivalence to previously cleared predicate devices.

    The key statement is on page 5: "Clinical Testing: There is no clinical testing required to support this submission."

    Therefore, I cannot provide the full response as requested, as the necessary information regarding acceptance criteria, reported performance, test set details, expert ground truth, adjudication, MRMC studies, standalone performance, and training set details are not present in the provided document.

    The document focuses on demonstrating that the proposed changes (wireless communication and the Beam F3 treatment location method) to the NeuroStar Advanced Therapy System do not raise new questions of safety or effectiveness when compared to its predicate devices. The "Performance Standards" section lists recognized consensus standards (ISO 10993-1, ANSI AAMI ES60601-1 / IEC 60601-1, IEC 60601-1-2, IEC 60601-1-6) and mentions non-clinical performance testing and usability testing were performed according to relevant guidance documents. However, this is related to safety and electrical performance, not clinical efficacy or device performance against specific metrics as would be found in a detailed clinical study report proving accuracy or effectiveness.

    Ask a Question

    Ask a specific question about this device

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NeuroStar Advanced Therapy system is intended to be used as an adjunct for the treatment of adult patients suffering from Obsessive-Compulsive Disorder (OCD).

    Device Description

    The NeuroStar Advanced Therapy System, for adjunctive treatment of OCD, is a computerized, electromechanical medical device that produces and delivers non-invasive magnetic fields to induce electrical currents targeting specific regions of the cerebral cortex. Transcranial magnetic stimulation (TMS) is a non-invasive technique used to apply brief magnetic pulses to the brain. The pulses are administered by passing high currents through an electromagnetic coil placed adjacent to a patient's scalp. The pulses induce an electric field in the underlying brain tissue. When the induced field is above a certain threshold and is directed in an appropriate orientation relative the brain's neuronal pathway, localized axonal depolarizations are produced, thus activating neurons in the targeted brain structure. The system consists of: 1. Mobile console 2. System software with GUI 3. Treatment chair 4. Head support system 5. Coil positioning system 6. Same Coil for both MT and treatment 7. Coil fixture 8. Data management system.

    AI/ML Overview

    The provided text describes the regulatory clearance for the NeuroStar Advanced Therapy System for the
    adjunctive treatment of Obsessive-Compulsive Disorder (OCD). The submission is a 510(k) premarket
    notification, which seeks to demonstrate substantial equivalence to a legally marketed predicate device.
    Therefore, the study design focuses on proving equivalence rather than meeting pre-defined acceptance
    criteria based on clinical efficacy outcomes or standalone algorithm performance.

    Here's the breakdown of information based on your request:

    1. Table of Acceptance Criteria and Reported Device Performance

    Since this is a 510(k) submission based on substantial equivalence, the "acceptance criteria" are
    primarily focused on demonstrating that the device's technological characteristics, safety, and
    performance are equivalent to a predicate device. There aren't traditional clinical efficacy
    acceptance criteria (e.g., a specific percentage improvement in OCD symptoms) as would be seen in a
    PMA or a clinical trial designed to establish de novo efficacy.

    The "acceptance criteria" are therefore implicit in the comparison to the predicate device and the
    adherence to recognized standards.

    Acceptance Criteria (Demonstrated Equivalence)Reported Device Performance
    Magnetic and Electric Field Properties Substantially Equivalent to Predicate Device (MagVenture Cool D-B80 coil) (based on Section 4 of FDA's Class II Special Controls Guidance)Magnetic Field Distribution: Measurements determined that the magnetic spatial distribution is substantially equivalent to the Cool D-B80 coil. Both coils are figure 8 designs, allowing for deep and broad stimulation of the cortex. Information about linearity of output level, magnetic field strength gradients, output waveform, and magnetic field spatial distribution was provided. Electric Field Distribution: Measurements determined that the linearity of the electric field output and the electric field spatial distributions are substantially equivalent to the Cool D-B80 coil. Overall: Performance testing confirmed equivalence in safety and performance based on electric field distribution, stimulation volume, magnetic field distribution, and magnetic flux, pulse timing. No new safety or effectiveness issues introduced.
    Safety - Sound Pressure Levels (in accordance with IEC60601 Edition 3.1)Complies with specified permissible sound pressure levels and permissible thresholds for exposure defined by OSHA. Provides evidence that the system does not pose any risk for potential hearing reduction or loss in either patients or operators.
    Conformity to Performance Standards (ISO 13485:2016, IEC60601-1, IEC60601-1-2)Successfully tested and conforms to ISO 13485:2016, IEC60601-1 Ed. 3.1, and IEC60601-1-2:2014.
    Software Verification and ValidationPerformed. Subject device functions as intended and meets the same acceptance as the primary predicate and predicate devices.
    Non-Clinical Performance Testing for Special Controls (per 21 CFRH 882.5802)Performed as required.
    Intended Use and Stimulation Parameters Equivalent to Primary Predicate Device (MagVenture TMS Therapy System - K193006) for OCD treatment (specifically regarding intensity, repetition rate, train duration, inter-train-interval, number of trains, pulses, total duration, and treatment area).The intended use for OCD is identical. The treatment parameters (intensity, repetition rate, train duration, inter-train-interval, number of trains, pulses, total duration, and treatment area - Dorsomedial Prefrontal Cortex) are reported as having "No Difference" compared to the primary predicate.

    2. Sample size used for the test set and the data provenance

    The document explicitly states: "This 510(k) does not contain any pivotal clinical trial data related
    to the new device. The substantial equivalency is established based on similar technological
    characteristics."
    Therefore, there is no clinical "test set" in the traditional sense of patient
    data for efficacy. The "test set" here refers to bench testing data comparing the subject device's
    physical characteristics to the predicate device. The provenance of this bench testing data is not
    specified (e.g., where the tests were physically conducted), but it refers to well-established
    scientific methods using standard scientific instrumentation. The specific sample sizes for these
    bench tests (e.g., number of coils tested) are not provided.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of
    those experts

    Not applicable. There was no clinical "test set" requiring expert ground truth in the context of this
    510(k) submission, which relied on bench testing and comparison to a predicate.

    4. Adjudication method for the test set

    Not applicable, as there was no clinical "test set" or expert review process for patient outcomes.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the
    effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is a Transcranial Magnetic Stimulation (TMS) system, not an AI or imaging
    diagnostic device, and no MRMC study was conducted or is relevant to this submission.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a medical device for treatment, not an algorithm. The "device performance"
    reported relates to its physical and functional characteristics (e.g., magnetic field, sound levels)
    and adherence to safety standards, not an algorithm's standalone diagnostic performance.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    For the bench testing, the "ground truth" was established by measurements using well-established
    scientific methods and standard scientific instrumentation
    , as referenced in Section 4 of the FDA's
    Class II Special Controls Guidance document for rTMS systems. This involves physical measurements of
    magnetic and electric fields.

    8. The sample size for the training set

    Not applicable. There is no "training set" as this is not an AI/ML algorithm that undergoes
    machine-learning training. The device's design and parameters are established through engineering and
    medical principles, not statistical learning from data.

    9. How the ground truth for the training set was established

    Not applicable. No training set for an algorithm was used.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201158

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-11-20

    (204 days)

    Product Code
    Regulation Number
    882.5805
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    NeuroStar Advanced Therapy is indicated for the treatment of Major Depressive Disorder in adult patients who have failed to receive satisfactory improvement from prior antidepressant medication in the current episode.

    Device Description

    The NeuroStar Advanced Therapy System is a computerized, electromechanical medical device that produces and delivers non-invasive, magnetic stimulation using brief duration rapidly alternating, or pulsed, magnetic fields to induce electrical currents directed at spatially discrete regions of the cerebral cortex. This method of cortical stimulation by application of brief magnetic pulses to the head is known as Transcranial Magnetic Stimulation (TMS).

    NeuroStar Advanced Therapy is a non-invasive tool for the stimulation of cortical neurons for the treatment of adult patients with Major Depressive Disorder (MDD) who have failed to receive satisfactory improvement from prior antidepressant medication in the current episode. NeuroStar Advanced Therapy is used for patient treatment by prescription only under the supervision of a licensed physician and can be used in both inpatient and outpatient settings including physician's offices, clinics, and hospitals.

    The proposed changes to the NeuroStar Advanced Therapy System described in this Traditional 510(k) Premarket Notification include the introduction of a new feature that allows the NeuroStar Advanced Therapy system to perform the TMS therapy known as intermittent theta burst stimulation (iTBS). NeuroBurst is the proprietary name for the iTBS treatment conducted by the NeuroStar Advanced Therapy System. The NeuroBurst treatment protocol consists of a burst of three (3) pulses at 50Hz with a 160ms interval between bursts. The protocol uses a train that consists of five (5) bursts per second for two (2) seconds with an eight (8) second interval between trains. A treatment session lasts for 20 trains or 3.3 minutes.

    The NeuroStar Advanced Therapy System is an integrated system consisting of a combination of the following components:

    • Mobile Console for housing the electronics and includes a software controlled graphical user interface, display monitor, display arm, and gantry that supports the treatment coil.
    • Ferromagnetic Coil for delivering treatment.
    • Head Support System for positioning the treatment coil and includes a laser-guided alignment system.
    • Multi-use consumable SenStar Treatment Link for contact sensing of the treatment coil with the patient's head and magnetic field quality control.
    • TrakStar Patient Data Management System for recording patient data and includes a stand-alone computer and data management software.
    AI/ML Overview

    The provided text is a 510(k) summary for the NeuroStar Advanced Therapy System, primarily focusing on demonstrating substantial equivalence to a predicate device and introducing a new feature (iTBS treatment, or NeuroBurst). It lacks the specific details required to answer your questions about acceptance criteria and a study proving a device meets these criteria in the context of an AI/ML medical device.

    The document describes a medical device (Transcranial Magnetic Stimulation System) for treating Major Depressive Disorder, not an AI/ML algorithm that predicts or diagnoses based on data. Therefore, the concepts of "test sets," "ground truth," "expert consensus," "MRMC studies," or "standalone algorithm performance" as typically applied to AI/ML device validation are not discussed.

    The "performance data" mentioned here refers to:

    • Physical performance of the device: magnetic field characteristics, output waveform, linear output level, electromagnetic compatibility (EMC), and electrical safety.
    • Comparison to predicate/reference devices: demonstrating that the NeuroStar system's technological characteristics, indications for use, and principles of operation are substantially equivalent. The clinical effectiveness of iTBS itself is supported by the reference device's prior FDA clearance, not a new clinical study presented in this 510(k) summary for the NeuroStar device's NeuroBurst feature.

    Therefore, I cannot extract the requested information as it is not present in the provided text.

    To illustrate what kind of information would be needed to answer your questions, here's a hypothetical example relevant to an AI/ML device, assuming the NeuroStar was an AI/ML device (which it is not, based on this document):


    Hypothetical Example (If NeuroStar were an AI/ML device):

    Let's imagine the NeuroStar Advanced Therapy System had an AI component designed to predict patient response to TMS therapy based on patient characteristics and brain imaging data.

    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria (for AI component: Prediction of Treatment Response)Reported Device Performance
    Primary Endpoints:
    Area Under the Receiver Operating Characteristic Curve (AUC) ≥ 0.85 (for predicting "Responder" vs. "Non-Responder")0.88
    Sensitivity for "Responder" prediction ≥ 80%82%
    Specificity for "Non-Responder" prediction ≥ 70%75%
    Secondary Endpoints:
    Positive Predictive Value (PPV) ≥ 75%78%
    Negative Predictive Value (NPV) ≥ 85%87%

    2. Sample size used for the test set and the data provenance

    • Test Set Sample Size: 500 patients
    • Data Provenance:
      • Country of Origin: Multi-center study including data from the United States (40%), United Kingdom (30%), and Canada (30%).
      • Retrospective/Prospective: Data collected prospectively from an observational cohort study specifically designed for AI model validation.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Number of Experts: 3 independent expert psychiatrists.
    • Qualifications of Experts: Each psychiatrist had at least 15 years of clinical experience in treating Major Depressive Disorder and specialized in TMS therapy. They were board-certified in psychiatry in their respective countries.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Adjudication Method: 3-reader consensus. If all three experts agreed on the patient's responder status (responder or non-responder), that was taken as the ground truth. In cases of disagreement (e.g., 2 agree, 1 disagrees), a fourth, senior adjudicating psychiatrist (not involved in initial readings) reviewed the case and made the final determination.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: Yes, an MRMC study was conducted.
    • Effect Size:
      • Without AI Assistance: Average AUC for human readers was 0.70 (95% CI: 0.68-0.72).
      • With AI Assistance: Average AUC for human readers improved to 0.80 (95% CI: 0.78-0.82).
      • Improvement (Effect Size): The AI assistance led to an average increase of 0.10 in AUC for human readers (p < 0.001), indicating a statistically significant improvement in their ability to predict treatment response.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Standalone Performance: Yes, standalone performance was evaluated. The AI algorithm achieved an AUC of 0.88, Sensitivity of 82%, and Specificity of 75%.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Type of Ground Truth: Clinical outcomes data (validated depression symptom scales, e.g., MADRS or HAM-D, post-treatment scores indicating significant reduction in symptoms) independently assessed by the 3 expert psychiatrists via patient records and follow-up data abstraction. This was augmented by their consensus-based clinical determination of "responder" status.

    8. The sample size for the training set

    • Training Set Sample Size: 5,000 patients.

    9. How the ground truth for the training set was established

    • Ground Truth Establishment for Training Set: Ground truth for the training set was established through retrospective review of patient electronic medical records from multiple institutions. "Responder" status was defined by a pre-specified threshold reduction in a standardized depression symptom scale (e.g., ≥50% reduction in HAM-D scores) at the end of the TMS treatment course, as documented by treating physicians. Data was then cross-referenced and anonymized by research coordinators. While not as rigorously adjudicated as the test set, standard clinical documentation was considered sufficient for training purposes given the large volume of data.