    K Number
    K030859

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2003-03-27

    (9 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Enamelite Porcelain Powders are aerosol devices intended to be used as spray applications of ceramic porcelains and glazes for dental restorations (crowns and bridges), which are produced in dental laboratories.

    Device Description

    Ceramic Finishing Glaze (Nova Ceramic Spray Glaze). The Enamelite Nova Ceramic Spray Glaze is essentially identical to that used in the Leach and Dillon Shake n Spray powders. It is made of glass frit and is applied to dental restorations in an aerosolized uncontaminated form. Like all other porcelain powders, the Nova Ceramic Spray Glaze is only applied on dental restorations in dental laboratories. As with the parent Leach and Dillon device, the Nova Ceramic Spray Glaze in an aerosol form decreases the in-process time of hand applied glazing methods while providing a substantially more even coating of glaze. Both the parent and modified devices allow the dental technician to apply glaze on either single or multiple units at one time. The Nova Ceramic Spray Glaze is used to construct restorations that fire at temperatures from 650° C to 930° C. Various types of porcelains that are compatible with Nova Glaze include porcelain-fused-to metal, pressed ceramic restorations and milled zircon restorations. The Nova Glaze enables the dental technician the ability to spray a glaze over unfired dental ceramic stains and over unfired add-on porcelains which some restorations may require to esthetically match the dental patient's natural teeth. This flexibility will make these adjustments more efficient for the technician saving multiple firings staining, shading and repairing restorations.

    Opaque Porcelain (Tru-Paque) The Tru-Paque opaque porcelain powder is a ceramic opaque spray porcelain intended to mask metal sub-structures. This provides a base layer for bonding additional translucent body porcelain layers of "Porcelain-Fused-to-Metal" (PFM) dental restorations. The purpose of opaque porcelains is to mask the dark color of metal sub-structures called "copings" used in porcelain-fused-to-metal constructed dental restorations, and to provide a layer to which translucent body porcelains are bonded. The Enamelite Tru-Paque is offered in an uncontaminated aerosolized form. As with the parent Leach and Dillon devices, the Tru-Paque opaque porcelain is applied on dental restorations in dental laboratories.

    AI/ML Overview

    The provided text is a 510(k) summary for a medical device called "Nova Ceramic Spray Glaze and Tru-Paque Opaque Porcelain." This document is a premarket notification to the FDA to demonstrate substantial equivalence to a predicate device. It is not a study report that details acceptance criteria and device performance in the way a clinical trial or a validation study for a diagnostic algorithm would.

    Therefore, many of the requested elements of your prompt, such as acceptance criteria, reported device performance metrics (like sensitivity, specificity, AUC), sample sizes for test sets, data provenance, number of experts, adjudication methods, MRMC studies, standalone performance, and ground truth establishment methods for training or test sets, are not applicable or not present in this type of regulatory submission.

    This document focuses on demonstrating that the new device is "substantially equivalent" to an already legally marketed predicate device (Leach and Dillon Shake and Spray Porcelain Powders - K895889). The primary method used here is comparing technological characteristics rather than extensive performance studies with statistically derived acceptance criteria.

    However, I can extract the information that is present:

    1. A table of acceptance criteria and the reported device performance

    The document does not specify quantitative acceptance criteria or detailed performance metrics in the way a diagnostic device would. Instead, it states:

    Acceptance Criteria (Implied)Reported Device Performance
    Function as intended and provide benefits over predicate."Verification and Validation testing of the Enamelite devices was successfully performed and demonstrates that the modified devices function as intended." Specific claimed benefits: "reduced particle size delivers a thinner more uniform coating resulting in more life-like dental restorations" and "decreases the in-process time of hand applied glazing methods while providing a substantially more even coating of glaze."
    Substantial Equivalence to Predicate Device (K895889)Demonstrated through comparison of technological characteristics: both are aerosol spray delivery systems for porcelain powders; both allow consistent/controllable applications. The key differences (reduced particle size) are presented as improvements that lead to better results.

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: Not specified. The document mentions "Verification and Validation testing" but does not detail the size or nature of the test sets used.
    • Data Provenance: Not specified. No information on country of origin or whether testing was retrospective/prospective.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Number of Experts: Not applicable/not specified. This type of submission does not involve expert-established ground truth for performance metrics in the context of diagnostic accuracy.
    • Qualifications of Experts: Not applicable/not specified.

    4. Adjudication method for the test set

    • Adjudication Method: Not applicable/not specified.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: No, this is not an AI-based diagnostic device. It is a dental material/delivery system.
    • Effect Size: Not applicable.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Standalone Study: Not applicable. This is not an algorithm or AI device.

    7. The type of ground truth used

    • Type of Ground Truth: Not applicable in the traditional sense of diagnostic accuracy. The "ground truth" for this device would be its physical and chemical properties, its ability to adhere, its aesthetic outcome, and its compatibility with dental restorations, verified through laboratory/bench testing rather than clinical expert consensus or pathology reports.

    8. The sample size for the training set

    • Sample Size for Training Set: Not applicable. This is not a machine learning or AI device that uses a "training set."

    9. How the ground truth for the training set was established

    • Ground Truth for Training Set: Not applicable.

    Summary of the Study that Proves the Device Meets Acceptance Criteria:

    The document states that "Verification and Validation testing of the Enamelite devices was successfully performed and demonstrates that the modified devices function as intended." This is a general statement typical of 510(k) submissions for devices like this. The core of the "proof" for substantial equivalence lies in the comparison of technological characteristics between the proposed device and the predicate device, as outlined in section 6 of the submission. The key arguments are:

    • Similar Mechanism: Both use aerosol spray delivery systems for porcelain powders.
    • Consistent Application: Both systems provide consistent and controllable applications.
    • Improved Feature: The only significant difference (reduced particle size) is presented as an improvement leading to "thinner more uniform coating resulting in more life-like dental restorations" and decreased in-process time.

    The FDA's finding of substantial equivalence (as indicated in the letter from Susan Runner, DDS, MA) confirms that based on the provided information, the device is considered as safe and effective as a legally marketed predicate device. This is primarily a regulatory determination based on technological comparison and general validation rather than a detailed performance study with explicit statistical acceptance criteria for diagnostic accuracy.