Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K160854

    Validate with FDA (Live)

    Date Cleared
    2016-12-19

    (266 days)

    Product Code
    Regulation Number
    878.5000
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The MaxBraid BroadBand Suture is intended for use in soft tissue approximation and/or ligation. The suture may be provided individually or be incorporated as a component, into surgeries where constructs including those with allograft or autograft tissue are used for repair.

    Device Description

    Both MaxBraid BroadBand and Expressbraid Broadband Suture consist of a stainless steel straight or curved needle attached to a strand 1.25mm flat suture with round USP size 1 suture ends or 1.5mm flat suture with round USP size 2 suture ends in 38″ lengths. MaxBraid Broadband suture is straight with a single crimped needle, whereas the Expressbraid Broadband suture is a looped construct (both ends crimped into a single needle). The MaxBraid BroadBand Sutures are braided, non-absorbable sutures available in an all blue suture [Chromium-cobaltaluminum-oxide <2.0% by weight per 21 CFR §73.1015] consisting of Ultra High Molecular Weight Polyethylene (UHMWPE) fibers, a white and green [D&C Green No. 6 per 21 CFR §74.3206] co-braid configuration consisting of UHMWPE and polyester (PET) fibers, and a white and black [Logwood Extract per §73.1410] co-braid configuration consisting of UHMWPE and nylon. The suture is provided uncoated.

    AI/ML Overview

    This document, K160854, describes the substantial equivalence determination for the MaxBraid BroadBand Suture and Expressbraid BroadBand Graft Manipulation Suture. It does not contain information about an AI-powered device or a study involving human readers and AI assistance. Therefore, it is not possible to answer the questions regarding acceptance criteria, study details, expert involvement, and ground truth establishment from the provided text.

    The document primarily focuses on demonstrating that the new suture devices are substantially equivalent to existing predicate devices (ExpressBraid Graft Manipulation and Arthrex Fiber Tape Suture) based on their intended use, indications for use, materials, design features, colorants, sterilization, and performance testing (knot tensile strength, needle attachment, biocompatibility, pyrogenicity, and shelf life).

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1