Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K052440

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2005-10-11

    (35 days)

    Product Code
    Regulation Number
    876.5130
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Mentor Self-Cath® HydroGel™ Intermittent Urethral Urinary Catheter is intended for use in male, female and pediatric patients requiring bladder drainage as determined by their physician. This device is indicated for those individuals who are unable to promote a natural urine flow or for those individuals who have a significant volume of residual urine following a natural bladder-voiding episode

    Device Description

    The Mentor Self-Cath® HydroGel™ catheter (hereafter referred to as SCHG) is an extension of the existing Mentor Self-Cath product line. The device is a modification of the Mentor Self-Cath® Plus catheter and the Mentor Self-Cath Closed System catheter.

    The SCHG is intended to be used to drain urine from the bladder. It is provided sterile and is for single-use only. It consists of a prelubricated catheter with an introducer tip on the proximal end which is designed to reduce patient contact and potential contamination while advancing the catheter into the urethra. The catheter is prelubricated with a water-soluble hydrophilic water-based lubricant. The catheter is packaged inside a thin flexible telescoping sleeve that is designed to extend from the catheter to the urine collection device or toilet during bladder voiding. The distal end of the sleeve includes a drainage port with a suction cup for attachment to the toilet, thus stabilizing the sleeve during the voiding process. The SCHG also has a reduced package size for ease of transport.

    The SCHG is available singly or as a kit with the following accessories included: non-latex gloves, a paper poly towel, PVP swabs, and a BZK towelette.

    AI/ML Overview

    The provided text describes a medical device, the Mentor Self-Cath® HydroGel™ Intermittent Urethral Urinary Catheter, and its 510(k) submission for substantial equivalence. It does not contain information about a study proving the device meets specific acceptance criteria in the context of an AI/ML medical device.

    Therefore, I cannot fulfill the request as it pertains to AI/ML device testing and acceptance criteria based on the provided input.

    The document details:

    • Device Description and Indications for Use: What the catheter is and its intended purpose.
    • Substantial Equivalence Claim: The manufacturer's claim that the device is substantially equivalent to previously cleared devices (Mentor Self-Cath Plus Catheter and Mentor Self-Cath Closed System).
    • Summary of Testing (Biocompatibility): This section describes the tests performed to ensure the device is safe for biological contact. These are standard biocompatibility tests, not performance studies as would be conducted for an AI/ML algorithm.

    The biocompatibility testing results essentially serve as the "acceptance criteria" and "reported performance" in this context, demonstrating that the materials are safe for their intended use.

    Here's how I would present the available information if forced to apply the request's structure, while highlighting the mismatch:


    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Biocompatibility)Reported Device Performance
    Cytotoxicity (Agar Diffusion – ISO Method): No cytotoxicity or < Grade 2 (mild reactivity) induced.The catheter portion did not induce cytotoxicity. The introducer tip portion induced cytotoxicity but with reactivity less than a Grade 2 (mild reactivity), meeting the criteria.
    Guinea Pig Maximization (Saline and Vegetable Oil Extracts): No signs of sensitization observed.No signs of sensitization were observed in guinea pigs treated with the test article, indicating it is not considered to elicit contact dermal allergenicity.
    Systemic Toxicity (Acute Systemic Injection with Saline and Vegetable Oil Extracts): Met requirements of the systemic injection test.The test article met the requirements of the systemic injection test.
    Acute Vaginal Irritation: Met requirements of the vaginal irritation test.The test article meets the requirements of the vaginal irritation test.

    Regarding the other requested points, the document does not contain the information relevant to an AI/ML medical device study:

    • 2. Sample sized used for the test set and the data provenance: Not applicable to biocompatibility testing.
    • 3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. Ground truth for biocompatibility is based on established scientific methods and standards.
    • 4. Adjudication method for the test set: Not applicable.
    • 5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable, as this is not an AI/ML device.
    • 6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable, as this is not an AI/ML device.
    • 7. The type of ground truth used (expert consensus, pathology, outcomes data, etc): For biocompatibility, the "ground truth" is derived from standardized assay results (e.g., cell viability in cytotoxicity, observed reactions in animal models for sensitization/irritation).
    • 8. The sample size for the training set: Not applicable (no training set for biocompatibility).
    • 9. How the ground truth for the training set was established: Not applicable (no training set for biocompatibility).

    Conclusion: The provided text describes a traditional medical device (catheter) and its regulatory clearance based on biocompatibility testing and substantial equivalence, not an AI/ML device. Therefore, most of the requested information regarding AI/ML study design and acceptance criteria is not present or applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K050008

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2005-06-03

    (151 days)

    Product Code
    Regulation Number
    876.5130
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Mentor Self-Cath® HydroGel™ Intermittent Urethral Urinary Catheter is intended for use in male, female and pediatric patients requiring bladder drainage as determined by their physician. This device is indicated for those individuals who are unable to promote a natural urine flow or for those individuals who have a significant volume of residual urine following a natural bladder-voiding episode

    Device Description

    The Mentor Self-Cath® HydroGel™ catheter (hereafter referred to as SCHG) is an extension of the existing Mentor Self-Cath product line. The device is a modification of the Mentor Self-Cath® Plus catheter and the Mentor Self-Cath Closed System catheter.

    The SCHG is intended to be used to drain urine from the bladder. It is provided sterile and is for single-use only. It consists of a prelubricated catheter with an introducer tip on the proximal end which is designed to reduce patient contact and potential contamination while advancing the catheter into the urethra. The catheter is prelubricated with a water-soluble hydrophilic water-based lubricant. The catheter is packaged inside a thin flexible telescoping sleeve that is designed to extend from the catheter to the urine collection device or toilet during bladder voiding. The distal end of the sleeve includes a drainage port with a suction cup for attachment to the toilet, thus stabilizing the sleeve during the voiding process. The SCHG also has a reduced package size for ease of transport.

    The SCHG is available singly or as a kit with the following accessories included: non-latex gloves, a paper poly towel, PVP swabs, and a BZK towelette.

    AI/ML Overview

    The provided text describes a medical device, the Mentor Self-Cath® HydroGel™ Intermittent Urethral Urinary Catheter, and its path to FDA clearance via a 510(k) submission (K050008). However, it does not include information about acceptance criteria or a study that proves the device meets those criteria in the context of performance metrics like sensitivity, specificity, accuracy, or similar measures typically used for diagnostic or AI-based devices.

    This submission focuses on substantial equivalence to predicate devices and biocompatibility testing rather than performance in terms of diagnostic effectiveness or clinical outcome improvement through a P-value or specific statistical analysis commonly found in clinical trials. As such, many of the requested fields cannot be filled from the provided text.

    Here's a breakdown based on the given information:

    1. A table of acceptance criteria and the reported device performance

    Acceptance CriteriaReported Device Performance
    Biocompatibility:
    Cytotoxicity (ISO Method)Catheter portion: Did not induce cytotoxicity. Introducer tip portion: Did introduce cytotoxicity, but reactivity was less than Grade 2 (mild reactivity).
    Guinea Pig Maximization (Saline & Vegetable Oil Extracts)No signs of sensitization observed.
    Systemic Toxicity (Acute Systemic Injection with Saline & Vegetable Oil Extracts)Met the requirements of the systemic injection test.
    Acute Vaginal IrritationMet the requirements of the vaginal irritation test.
    Genotoxicity (Ames Test)Extracts were not mutagenic for any tester strain, with or without S9 activation.
    Substantial Equivalence:The device is considered substantially equivalent in form and function to the Mentor's Self-Cath Plus Catheter (K003874) and the Self-Cath Closed System (K003873).

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: Not specified for biocompatibility tests (e.g., number of units tested, number of animals). This information is usually detailed in the full test reports, which are not included in this summary.
    • Data Provenance: Not specified. The tests are general biocompatibility tests, not clinical studies in humans or specific geographical data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not applicable. This submission concerns the biocompatibility and substantial equivalence of a physical medical device, not a diagnostic algorithm requiring expert-established ground truth.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    • Not applicable. This type of adjudication is typically used for image-based diagnostics or clinical studies where subjective interpretation is involved.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No MRMC study was done. This is not an AI-assisted device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This is not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • For biocompatibility, the "ground truth" is established by the results of standardized biological tests (e.g., observation of cellular reactions, animal responses to extracts, genotoxicity assays) and comparison against acceptance criteria defined by relevant ISO standards or regulatory guidelines.
    • For substantial equivalence, the "ground truth" is the established safety and effectiveness of the predicate devices.

    8. The sample size for the training set

    • Not applicable. This is not a machine learning or AI device that requires a training set.

    9. How the ground truth for the training set was established

    • Not applicable.
    Ask a Question