Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K130335

    Validate with FDA (Live)

    Date Cleared
    2013-04-19

    (67 days)

    Product Code
    Regulation Number
    888.3045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    MASTERGRAFT® Strip and MASTERGRAFT® UltraMatrix are to be combined with autogenous bone marrow and are indicated for bony voids or gaps that are not intrinsic to the stability of the bony structure and can be used as a bone graft extender.

    The device is to be gently packed into bony voids or gaps of the skeletal system (i.e., the posterolateral spine, pelvis, ilium, and/or extremities). These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone. The device resorbs and is replaced with bone during the healing process.

    Device Description

    MASTERGRAFT® Strip and MASTERGRAFT® UltraMatrix consist of a combination of medical grade purified collagen of bovine origin and biphasic calcium phosphate ceramic. In the MASTERGRAFT® Strip and MASTERGRAFT® UltraMatrix devices, the collagen is a highly purified (>95%) Type I bioresorbable Iyophilized collagen. The biphasic ceramic portion of MASTERGRAFT® Strip and MASTERGRAFT® UltraMatrix is provided in a 15 percent hydroxyapatite and 85 percent B-tricalcium phosphate formulation.

    MASTERGRAFT® Strip and MASTERGRAFT® UltraMatrix are supplied sterile in a premixed strip form for single patient use.

    MASTERGRAFT® Strip and MASTERGRAFT® UltraMatrix devices are biocompatible, osteoconductive, porous implants that allow for bony ingrowth across the graft site while resorbing at a rate consistent with bone healing. The devices readily absorbs bone marrow aspirate and had been shown to heal bone defects.

    The purpose of this Special 510(k) application is to add additional sizes (known as MASTERGRAFT® UltraMatrix 5cc, 10cc, and 20cc) to the previously cleared MASTERGRAFT® Strip product family. The sizes proposed in this Special 510(k) were part of the original product design for MASTERGRAFT® Strip device, and were included in the design verification and validation activities reported in K082166.

    AI/ML Overview

    The provided text is a 510(k) Summary for a medical device (MASTERGRAFT® Strip and MASTERGRAFT® UltraMatrix), which focuses on demonstrating substantial equivalence to a predicate device rather than presenting a study with specific acceptance criteria and performance metrics in the way one would for a novel device or AI.

    The core of this document is a comparison to a previously cleared predicate device (MASTERGRAFT® Strip, K082166). The "study" here is essentially the non-clinical testing performed to show that the new device sizes (MASTERGRAFT® UltraMatrix 5cc, 10cc, and 20cc) are "substantially equivalent" to an existing, cleared device. This means the acceptance criteria are largely based on meeting recognized consensus standards for medical device materials, biocompatibility, and manufacturing, and showing that the new device has the same technological characteristics and performance as the predicate.

    Here's an breakdown based on the information provided, keeping in mind the context of a 510(k) for a substantially equivalent device:


    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Criteria / StandardReported Device Performance (vs. Predicate)
    Indications for UseIdentical to K082166Identical
    Fundamental Scientific TechnologyIdentical to K082166 (Operating Principle, Mechanism of Action)Identical
    Basic DesignIdentical to K082166Identical
    PerformanceEquivalent to K082166Identical
    Manufacturing PrinciplesIdentical to K082166Identical
    SterilizationIdentical to K082166Identical
    Shelf-LifeIdentical to K082166Identical
    PackagingIdentical to K082166Identical
    Material CompositionIdentical to K082166 (Collagen, Biphasic Calcium Phosphate Granules)Identical
    Need for Rigid FixationIdentical to K082166Identical
    Safety and Effectiveness ProfileIdentical to K082166Identical
    BiocompatibilityConformance to ISO 10993 series (Parts 3, 4, 5, 6, 10, 11, 12)Demonstrated conformance in predicate K082166; new device sizes are identical in material and processing.
    Material Composition (Specific)Conformance to ASTM F1185-03 (Hydroxyapatite) & ASTM F1088-04a (ß-tricalcium Phosphate)Demonstrated conformance in predicate K082166; new device sizes are identical in material.
    Animal Tissue ManagementConformance to ISO 22442 series (Parts 1, 2, 3)Demonstrated conformance in predicate K082166; new device sizes are identical in material.
    Device Size (Minor Variation)New proposed sizes within product family (5cc, 10cc, 20cc) as part of original design verification/validation of predicateReported new sizes: 5cc (L: 4.7cm, W: 1.0cm, T: 1.1cm), 10cc (2x 5cc), 20cc (L: 4.7cm, W: 1.9cm, T: 1.1cm)

    2. Sample Size for Test Set and Data Provenance

    The document explicitly states: "The sizes proposed in this Special 510(k) were part of the original product design for MASTERGRAFT® Strip device, and were included in the design verification and validation activities reported in K082166." This indicates that the supporting data comes from the initial clearance of the predicate device (K082166). The document does not specify exact sample sizes for each non-clinical test mentioned, nor does it specify the country of origin of the data or if it was retrospective or prospective, beyond stating it was "non-clinical testing."

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    Not applicable in the context of this 510(k). This submission relies on non-clinical (laboratory/material) testing and comparison to a predicate device, not expert human assessment of diagnostic images or clinical outcomes that would require ground truth established by experts.

    4. Adjudication Method for the Test Set

    Not applicable. The testing described is non-clinical (material characterization, biocompatibility, etc.) and does not involve human adjudication of results in the way a diagnostic study would.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and Effect Size

    No. This document does not describe an MRMC study. The device is a bone void filler, not an imaging or diagnostic AI device that would typically undergo such a study.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop) Performance Was Done

    Not applicable. The product is a physical bone void filler, not a software algorithm.

    7. The Type of Ground Truth Used

    The "ground truth" here is the established scientific and regulatory standards for medical device materials, biocompatibility, and performance, as well as the performance and characteristics of the legally marketed predicate device. This is primarily based on:

    • Expert Consensus Standards: such as ASTM and ISO standards listed (e.g., ISO 10993 for biocompatibility, ASTM for material composition).
    • Predicate Device Performance: The "truth" is that the new sizes of the device are identical in all critical aspects and therefore perform equivalently to the predicate (K082166), which has already been found safe and effective.

    8. The Sample Size for the Training Set

    Not applicable. This device does not involve a "training set" in the context of machine learning or AI.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable for the same reason as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K082166

    Validate with FDA (Live)

    Date Cleared
    2009-06-02

    (306 days)

    Product Code
    Regulation Number
    888.3045
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    MASTERGRAFT® Strip is to be combined with autogenous bone marrow and is indicated for bony voids or qaps that are not intrinsic to the stability of the bony structure and can be used as a bone graft extender.

    The device is to be gently packed into bony voids or gaps of the skeletal system (i.e., the posterolateral spine, pelvis, ilium, and/or extremities). These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone. The device resorbs and is replaced with bone during the healing process.

    Device Description

    MASTERGRAFT® Strip is made from a combination of medical grade purified collagen and biphasic calcium phosphate ceramic. In the MASTERGRAFT® Strip device, the collagen is a highly purified (s95%) Type I bioresorbable lyophilized collagen. The biphasic ceramic portion of all devices is provided in a 15% hydroxyapatite and 85% b-tricalcium phosphate formulation.

    MASTERGRAFT® Strip is supplied sterile in a premixed strip form for single patient use.

    MASTERGRAFT® Strip is a biocompatible, osteoconductive, porous implant that allows for bony ingrowth across the graft site while resorbing at a rate consistent with bone healing. The device readily absorbs bone marrow aspirate and has been shown to heal bone defects.

    AI/ML Overview

    This document is a 510(k) Summary for the Medtronic Sofamor Danek MASTERGRAFT® Strip, a resorbable calcium salt bone void filler device. It focuses on establishing substantial equivalence to previously cleared predicate devices rather than presenting a study with specific acceptance criteria and performance data in the way you've outlined for AI/diagnostic devices.

    Therefore, the requested information categories are largely not applicable to this type of regulatory submission. The document explicitly states: "Documentation is provided that demonstrates MASTERGRAFT® Strip to be substantially equivalent to the previously cleared..."

    Here's a breakdown of why many of your categories cannot be filled from this text:

    • Acceptance Criteria & Device Performance: This document does not describe specific numerical acceptance criteria (e.g., sensitivity, specificity, accuracy) or quantitative performance metrics for the MASTERGRAFT® Strip. Its purpose is to demonstrate equivalence based on material composition, intended use, and general safety/effectiveness features.
    • Study Details (Sample Size, Data Provenance, Experts, Adjudication, MRMC, Standalone): There is no mention of a clinical study designed to test the device's performance against specific acceptance criteria. This implies that the substantial equivalence was likely demonstrated through non-clinical testing (e.g., biocompatibility, material characterization, mechanical properties) and comparison to predicate devices, rather than a prospective clinical trial with human subjects for performance evaluation in the context of imaging or diagnostic tasks.
    • Ground Truth: Since there's no clinical performance study described, there's no "ground truth" established in the way it would be for a diagnostic tool (e.g., confirming disease presence). The "ground truth" for a bone void filler is ultimately successful bone healing and integration, which would be assessed in clinical use, but not typically as part of a 510(k) summary for substantial equivalence.
    • Training Set: As no AI or algorithm is involved, there is no training set.

    Summary of available information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance: This information is not provided. The document's purpose is to demonstrate substantial equivalence to predicate devices, not to present performance against specific numerical acceptance criteria.

    2. Sample Size Used for the Test Set and Data Provenance: Not applicable. No clinical "test set" in the context of performance metrics (like for a diagnostic device) is described. Substantial equivalence is based on comparison to predicate devices and material characteristics.

    3. Number of Experts Used to Establish Ground Truth and Qualifications: Not applicable. Ground truth as typically defined for diagnostic or AI studies is not relevant here.

    4. Adjudication Method: Not applicable.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study: Not applicable. This is not an AI or diagnostic device that would typically undergo such a study.

    6. Standalone Performance Study: Not applicable. This is not an algorithm, so "standalone performance" for an algorithm is not relevant. The device itself is "standalone" in its physical form.

    7. Type of Ground Truth Used: Not applicable in the traditional sense of a diagnostic study. The "ground truth" for a bone void filler is successful bone healing and integration, which is assessed clinically but not detailed as a "ground truth" method for this 510(k) summary.

    8. Sample Size for the Training Set: Not applicable. This is not an AI/ML device.

    9. How the Ground Truth for the Training Set was Established: Not applicable.


    Key information from the provided text:

    • Device Name: MASTERGRAFT® Strip
    • Product Description: Made from a combination of medical grade purified collagen and biphasic calcium phosphate ceramic (15% hydroxyapatite, 85% b-tricalcium phosphate). It is biocompatible, osteoconductive, porous, absorbs bone marrow aspirate, and resorbs while being replaced with bone.
    • Intended Use/Indications: To be combined with autogenous bone marrow for bony voids or gaps not intrinsic to bony structure stability, and as a bone graft extender. Packed into bony voids/gaps of the skeletal system (posterolateral spine, pelvis, ilium, extremities), which can be surgically created or due to traumatic injury.
    • Regulatory Pathway: 510(k) Premarket Notification, seeking substantial equivalence.
    • Predicate Devices:
      • MASTERGRAFT® Matrix (K023553)
      • MASTERGRAFT® Putty (K071813)
      • OssiMend Bone Graft Material (K052812)
      • Collagraft Strip Bone Graft Material (K000122)
      • Integra MOZAIK™ Osteoconductive Scaffold - Strip (K063124)
    • Conclusion of the 510(k) Summary: The documentation demonstrates MASTERGRAFT® Strip to be substantially equivalent to the listed predicate devices.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1