    K Number
    K211306

    Validate with FDA (Live)

    Device Name
    LABYRINTH
    Date Cleared
    2021-06-24

    (56 days)

    Product Code
    Regulation Number
    888.3080
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    When used as a cervical intervertebral body fusion device, the LABYRINTH implants are intended to be used with autograft or allogenic bone graft comprised of cancellous and/or corticancellous bone graft in skeletally mature patients. Cervical IBF implants are intended for use at one level in the cervical spine, from C2 to T1, for the treatment of cervical disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies). The cervical device is intended to be used in patients who have had six weeks of non-operative treatment.

    When used as a lumbar intervertebral body fusion device, the LABYRINTH implants are intended to be used with autograft or allogenic bone graft comprised of cancellous and/or corticancellous bone graft in skeletally mature patients. The lumbar IBF implants are intended for use at either one level or two contiguous levels in the lumbar spine, from L2 to S1, for the treatment of degenerative disc disease (DDD) with up to Grade I spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The lumbar device is intended to be used in patients who have had six months of non-operative treatment.

    For all the above indications the LABYRINTH implants are intended to be used with supplemental internal fixation appropriate for the implanted level, including Zavation Pedicle Screw System and Zavation Cervical Plate System.

    Device Description

    The LABYRINTH implants offers a variety of heights, widths, and lengths. There are six main configurations: ALIF, LLIF, TLIF, T-PLIF and CIF. The different configurations allow for multiple surgical technique options. The implants are manufactured from medical grade PEEK (Polyetheretherketone).

    The LABYRINTH implants are available in a range of sizes, as well as parallel and lordotic angled implants, to accommodate variations in patients' anatomy. In addition, tantalum beads or pins are embedded in the implants as an option to help allow for radiographic visualization. The ends of the implants have machined teeth which are designed to engage with the vertebral body end plates. The LABYRINTH device includes a porous structure on the endplate and through the device. This submittal seeks clearance for LABYRINTH implants will be provided sterile.

    AI/ML Overview

    This looks like an FDA 510(k) clearance letter for a medical device called LABYRINTH, an intervertebral body fusion device.

    Crucially, this document does NOT describe the acceptance criteria or a study related to an AI/ML powered device. It describes the performance testing of a physical medical implant, specifically mechanical and biomechanical testing, to demonstrate its substantial equivalence to a predicate device.

    Therefore, I cannot provide the information requested in your prompt as it pertains to AI/ML device performance evaluation methods (e.g., sample sizes for test/training sets, expert consensus, MRMC studies, ground truth establishment, etc.). The document focuses on the mechanical and material properties of the LABYRINTH implant.

    To answer your prompt, I would need a document detailing the performance study of an AI/ML-powered medical device.

    If you can provide a document relevant to an AI/ML device, I would be happy to analyze it according to your requested criteria.