510(k) Data Aggregation

    K Number
    K254003

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-01-09

    (25 days)

    Product Code
    Regulation Number
    888.3660
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The prostheses from FH Industrie are designed for specific indications such as:

    Simple humeral prosthesis

    • Humeral head necrosis without injury to the glenoid cavity.
    • Extensive humeral head cartilage damage without injury to the glenoid cavity
    • Centred osteoarthritis with a glenoid cavity not allowing implantation of a glenoid implant.
    • Rheumatoid polyarthritis with thin rotator cuff.
    • Off-centred osteoarthritis with irreparable cuff, and with maintained active elevation of at least 120°.

    Total anatomical prosthesis (cemented glenoid implant with pegs)

    • Centred glenohumeral osteoarthritis with functional rotator cuff
    • Rheumatoid polyarthritis with functional rotator cuff
    • Post-traumatic sequela, functional rotator cuff with glenoid injury.

    TOTAL ANATOMICAL PROSTHESIS (POROUS GLENOID IMPLANT)

    • Centred glenohumeral osteoarthritis
    • Rheumatoid polyarthritis
    • Post-traumatic sequela with glenoid injury
    • Revision for glenoid loosening
    • Glenoid bone loss, where bone graft is needed

    A functional rotator cuff is necessary to use this device

    REVERSE PROSTHESIS (METAL-BACK OR POROUS GLENOID IMPLANT)

    The ARROW and JARVIS Reverse Shoulder Prosthesis is indicated for patients with severe shoulder arthropathy and a grossly deficient rotator cuff or a previously failed shoulder joint replacement with a grossly deficient rotator cuff. A functional deltoid muscle and adequate glenoid bone stock are necessary to use this device.

    At least 2/3 of the metaphyseal component must be implanted in the proximal humeral bone to allow for adequate humeral component fixation. Metaphyseal stems and diaphyseal stems are intended for use without cement. The glenoid bases (metal-back or porous) are intended for cementless use with the addition of cortical and cancellous bone screws.

    Device Description

    The JARVIS Metaphyseal Stem is modification to the metaphysis component of the Arrow Short Stem prosthesis (K202024). The Metaphyseal Stem is intended to be used with the diaphyseal component of the modular ARROW Short Stem device (K202024), including the JARVIS Diaphyseal Stem Standard (K253345). The subject modifications include optimized leading edges as well as the inclusion of suture holes for soft tissue reattachment. The JARVIS Metaphyseal Stem is offered in various sizes to accommodate patient anatomy. All implantable components are manufactured from medical grade titanium alloy (Ti6Al4V-ELI) per ASTM F-136/ISO 5832-3 with a pure titanium plasma spray coating per ASTM F1580.