510(k) Data Aggregation

    K Number
    K191093

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-01-22

    (272 days)

    Product Code
    Regulation Number
    876.5820
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Isopure Corp Dry Acid Dissolution System is designed to mix dry acid concentrates with purified water to produce an acid concentrate solution for hemodialysis for use in 3- Stream (acid concentrate, bicarbonate concentrate, and water) hemodialysis machines.

    Device Description

    The Isopure Dry Acid Dissolution System consists mainly of a Mixing Tank, a Distribution and Mixing Pump, a Hopper (with or without an automated opening mechanism), a Venturi inductor, and accompanying hydraulics and control circuits and sensors. The users will enter the dry acid powder mix into the Hopper either manually or by means of the automated bag opening mechanism. The contents of the Hopper will be drawn into the Mixing Tank by means of the Venturi inductor and the Distribution and Mixing Pump. Once all bags have been entered and the solution thoroughly mixed, the reading of the hydrostatic pressure inside the Tank will be converted into a specific gravity value. This in turn will be used to verify that the proper solution has been prepared against a pre-loaded table of values provided by the powder manufacturer. If the solution passes this verification, the system will allow transferring of the solution to the corresponding storage tank in the facility. The tanks will be identified by the use of quick connectors with RFID to prevent the transfer hose from being connected to the wrong tank.

    AI/ML Overview

    The provided text describes the Isopure Dry Acid Dissolution System, a medical device for preparing hemodialysis solutions. However, it does not describe an AI/ML-based medical device. Therefore, it does not contain the information required to answer the prompt regarding acceptance criteria and a study proving the device meets those criteria for an AI/ML device.

    The document is a 510(k) summary for a traditional medical device. It lists non-clinical performance data and explicitly states: "No clinical performance testing was required for determination of substantial equivalence of this type and class of device."

    Therefore, I cannot provide the requested information, particularly points 1-9, as they pertain to the evaluation of an AI/ML medical device, which is not what this document describes.