    The Step®family of products are intended for use during minimally invasive surgery for temporary dilation access to the abdominal and thoracic cavities for passage of diagnostic and operative instruments into the abdominal and thoracic cavities. The device is configured to be used as either a primary or secondary stick.

    Device Description

    The Step® family of products consist of an expandable dilator sheath assembly with an access (Veress-type) needle mounted within its lumen. The tubular member of the dilator sheath is configured so as to be axially compressed to reduce the outside diameter of the device prior to insertion. Upon use, the expanding dilator sheath/needle assembly is inserted through the abdominal/thoracic tissue into the abdominal/thoracic cavity. After insufflation of the cavity, (if deemed necessary), the access needle is removed. The dilator cannula assembly, which consists of a blunt obturator, dilation cannula, and a pneumo valve, is inserted through the lumen of the dilator sheath which expands radially to accommodate it. This process in turn, radially expands the walls of the surrounding tissue. Following dilation the obturator is removed, leaving the expanding dilation sheath and dilator cannula in place to provide a sealed port for passage of diagnostic and surgical instruments.

    This system configuration allows the user to initially place a small diameter dilator cannula for passage of small diagnostic instruments. The dilator cannula can then be removed from the lumen of the dilator sheath while leaving the sheath inserted through the tissues. A larger diameter dilation cannula can then be inserted through the dilator sheath to create a larger port for passage of the larger operative instruments.

    AI/ML Overview

    The provided text is a summary of safety and effectiveness information for a medical device (InnerDyne, Inc., OneStep® device), a type of dilator with a sheath used in minimally invasive surgery. It describes the device, its function, and claims substantial equivalence to predicate devices. However, this document does not describe an AI/ML device or a study proving that an AI/ML device meets specific acceptance criteria.

    Therefore, I cannot extract the information required by your request, as it pertains to AI/ML device performance and testing, which is not present in the provided text. The document focuses on the mechanical and functional aspects of a surgical dilator, comparing it to previous versions and existing surgical tools.