510(k) Data Aggregation

    K Number
    K971366

    Validate with FDA (Live)

    Device Name
    INCUWARMER
    Manufacturer
    Date Cleared
    1998-01-05

    (266 days)

    Product Code
    Regulation Number
    880.5130
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The IncuWarmer is a mobile, caster mounted, neonatal device which is used to assist in maintaining an infant's skin temperature and thermal environment. The device accomplishes this through the use of radiant and convective heat. Accessories and options to the device permit environmental control and monitoring including phototherapy capability, scale, and humidification. It is intended for in-patient use in maternity nurseries, and neonatal care environments of hospitals or other healthcare facilities.

    Device Description

    The IncuWarmer is a warming device that combines the heating technologies of both incubators and radiant warmers into one product. The IncuWarmer provides thermal isolation primarily through a convective air system with canopies and side panels to form an enclosure that isolates the air surrounding the infant from the room air. The IncuWarmer offers access to the infant by allowing the cargiver to open port holes, side panels, canopies, and, if more access is needed, raising up of the over head arm. The over head arm is the upper half of the infant enclosure containing the canopies. The over head arm can be is raised to obtain full access to the infant. The over head arm contains two tubular stainless steel infrared heaters that provide supplementary heat when the canopies and side panels are closed and primary heat when the canopies are opened or the over head arm is raised.

    In addition to providing thermal support, the IncuWarmer is capable of controlling options and accessories to aid the caregiver in rendering care to the infant. The IncuWarmer accessories are designed to operate with the IncuWarmer and consist of a humidification accessory, phototherapy accessory, and scale accessory for weighing the infant.

    AI/ML Overview

    This document is a 510(k) summary for the IncuWarmer, an infant radiant warmer. It does not contain information about acceptance criteria or a study proving device performance against such criteria. Instead, it focuses on demonstrating substantial equivalence to predicate devices.

    Therefore, the requested information cannot be extracted from the provided text. The document does not describe:

    1. A table of acceptance criteria and reported device performance.
    2. Sample sizes or data provenance for a test set.
    3. Number or qualifications of experts for ground truth establishment.
    4. Adjudication method for a test set.
    5. A multi-reader multi-case (MRMC) comparative effectiveness study.
    6. A standalone (algorithm only) performance study.
    7. The type of ground truth used.
    8. The sample size for a training set.
    9. How ground truth for a training set was established.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1