Found 2 results

510(k) Data Aggregation

    K Number
    K103223

    Validate with FDA (Live)

    Date Cleared
    2010-12-21

    (50 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Total joint replacement is indicated for patients suffering from disability due to:

    • degenerative, post-traumatic or rheumatoid arthritis; .
    • avascular necrosis of the femoral condyle; .
    • post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, . dysfunction or prior patellectomy;
    • . moderate valgus, varus or flexion deformities;
    • Treatment of fractures that are unmanageable using other techniques .
      This device may also be indicated in the salvage of previously failed surgical attempts. This device is intended to be used with the 3DKnee System for cemented or uncemented applications.
    Device Description

    Subject of this Traditional 510(k) Premarket Notification is a request for labeling claims for the DJO Surgical 3DKnee HXL VE Tibial Insert. The in vitro wear claim will be made for the use of the 3DKnee femoral component coupled with a 3DKnee HXL VE Insert. It is important to note that there are no new total knee components being introduced as a result of this Traditional 510(k) premarket notification.

    AI/ML Overview

    Acceptance Criteria and Study for DJO Surgical HXL VE Tibial Insert

    This document analyzes the acceptance criteria and supporting studies for the DJO Surgical Highly Cross-Linked Vitamin E UHMWPE (HXL VE) Tibial Insert, based on the provided K103223 510(k) summary.


    1. Table of Acceptance Criteria and Reported Device Performance

    The device demonstrates substantial equivalence to predicate devices based on five key claims. The acceptance criteria and reported performance for each claim are detailed below. It's important to note that the acceptance criteria are generally implied as either not showing significant degradation (for properties like oxidation resistance, mechanical strength after aging) or demonstrating performance at least equivalent to, or superior to, control/predicate materials.

    ClaimAcceptance Criteria (Implied)Reported Device Performance (HXL VE)
    Claim 1: No measurable oxidation during accelerated aging.Oxidation index < 0.1; No reduction in impact resistance after accelerated aging.Oxidation indices: Non-aged: 0.04±0.02, 2 weeks aged: 0.04±0.00, 4 weeks aged: 0.03±0.02. Average impact resistance: Before aging: 96.2±12.3 KJ/m², After aging: 102.3±13.3 KJ/m².
    Claim 2: Maintains mechanical strength of conventional CM UHMWPE.Yield strength comparable to CM UHMWPE; At least equivalent resistance to posterior peel-out force as CM inserts.Average yield strength after aging: 25.09±0.72 MPa (comparable to CM at 24.98±0.76 MPa). Average peel-out resistance: 182.43±2.23 lbs (greater than CM at 169.67±18.18 lbs).
    Claim 3: Maintains mechanical strength after accelerated aging.No significant decrease in yield strength, ultimate load, or impact resistance after accelerated aging.Average yield strength: Before aging: 26.76±0.96 MPa, After aging: 25.09±0.72 MPa (not a significant decrease). Average ultimate load: Before aging: 80.80±4.56 N, After aging: 81.31±4.22 N (no decrease). Average impact resistance: Before aging: 96.2±12.3 KJ/m², After aging: 102.3±13.3 KJ/m² (no reduction, slight increase).
    Claim 4: Reduced wear rate compared to conventional DCM UHMWPE.Average wear rate significantly less than conventional DCM UHMWPE.Average wear rate: 1.9±1.9 mg/million cycles (57% less than DCM at 4.4±3.0 mg/million cycles, p<0.01).
    Claim 5: Classified as a non-irritant.Irritant Ranking Score within the non-irritant range (0.0 - 2.9).Irritant Ranking Score: -0.6 (classified as non-irritant).

    2. Sample Size Used for the Test Set and Data Provenance

    The studies primarily rely on in vitro and ex vivo bench testing, and animal studies. Therefore, typical "test sets" of human patient data are not applicable here.

    • Claim 1 (Oxidation & Impact):
      • Oxidation: Samples of HXL VE tibial inserts at three time points (non-aged, 2 weeks aged, 4 weeks aged). The exact number of samples per time point is not specified but standard deviation is given, implying multiple samples. Comparison to Compression Molded UHMWPE (CM) at 2 weeks aged.
      • Impact: HXL VE test specimens and CM control specimens. Exact numbers not specified but implies multiple specimens for statistical analysis. Pre and post-accelerated aging.
      • Provenance: Laboratory testing (in vitro). Not applicable for country of origin or retrospective/prospective.
    • Claim 2 (Mechanical Strength - Tensile & Peel-out):
      • Tensile: CM, Highly Cross-Linked (HXL), and HXL VE material. All test specimens accelerated aged. Exact numbers not specified but standard deviation given.
      • Peel-out: Tibial insert test parts for both CM and HXL VE material. Exact number not specified but standard deviation given.
      • Provenance: Laboratory testing (in vitro).
    • Claim 3 (Mechanical Strength after aging - Tensile, Small Punch, Impact):
      • Tensile, Small Punch, Izod Impact: HXL VE material (before and after accelerated aging). Exact numbers not specified but standard deviations given.
      • Provenance: Laboratory testing (in vitro).
    • Claim 4 (Wear Rate):
      • Wear testing on 3D™ Knee system, comparing DCM and machined HXL VE tibial inserts. Each test performed for 5 million cycles. Both inserts were Size 6 Left. The study implies multiple replicate tests to generate the average wear rates and standard deviations for both DCM and HXL VE.
      • Provenance: Laboratory testing (in vitro).
    • Claim 5 (Biocompatibility/Irritation):
      • Sample Size: Three healthy adult New Zealand White rabbits. Five HXL VE sites and five CM sites implanted for each rabbit (total 15 HXL VE implants and 15 CM implants).
      • Provenance: Animal study (ex vivo tissue analysis). Not applicable for country of origin or retrospective/prospective in a human context.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    • For in vitro and ex vivo materials testing (Claims 1-4): Ground truth is established by the methodologies and interpretations of standard ASTM and ISO test protocols. This typically involves trained laboratory technicians and engineers who understand the specific test procedures and material science principles. The exact number or qualifications of individuals interpreting these specific test outputs are not provided but are assumed to be experts in materials testing.
    • For Biocompatibility (Claim 5):
      • Number of Experts: A single veterinary pathologist microscopically evaluated the H&E stained tissue sections.
      • Qualifications: "veterinary pathologist." No further details on years of experience are provided, but this implies specialized training and certification in veterinary pathology.

    4. Adjudication Method for the Test Set

    Given that the studies are primarily in vitro and ex vivo bench testing, and an animal study:

    • For Claims 1-4 (Materials Testing): Adjudication, in the sense of expert consensus on ambiguous findings, is generally not applicable. Performance is measured objectively according to standard test methods (e.g., ASTM, ISO), which define measurable outputs. Any interpretation would follow established scientific and engineering principles.
    • For Claim 5 (Biocompatibility): The microscopic evaluation was performed by a single veterinary pathologist. Therefore, no formal multi-expert adjudication method (like 2+1 or 3+1) was explicitly stated or performed for this specific test. The pathologist's evaluation would constitute the ground truth for irritant scoring.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No, an MRMC comparative effectiveness study was not done. This type of study typically evaluates the performance of human readers (e.g., radiologists) with and without AI assistance on diagnostic imaging cases. The provided document details in vitro and animal studies for a medical implant material, not a diagnostic AI device.


    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    Not applicable. The device is a physical knee implant component, not an algorithm or a software device. Therefore, a standalone algorithm performance study is not relevant.


    7. Type of Ground Truth Used

    • For Claims 1-4 (Material Properties and Wear): The ground truth is based on standardized physical and chemical measurements obtained through established ASTM and ISO protocols. This includes quantitative data for oxidation indices, impact resistance, tensile strength, peel-out force, and wear rates.
    • For Claim 5 (Biocompatibility): The ground truth is established by expert pathological evaluation of tissue samples (microscopic analysis by a veterinary pathologist) and subsequent calculation of a quantitative Irritant Ranking Score based on observed tissue reactions.

    8. Sample Size for the Training Set

    Not applicable. This device is a physical implant, not a software or AI device that requires a "training set" in the context of machine learning. The manufacturing processes and material formulations are based on established engineering principles and prior research, not on a machine learning training dataset.


    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no "training set" in the machine learning sense for this device. The development and validation of the material are based on non-clinical testing against industry standards and comparisons to predicate devices and control materials.

    Ask a Question

    Ask a specific question about this device

    K Number
    K091956

    Validate with FDA (Live)

    Date Cleared
    2010-09-28

    (454 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Joint replacement is indicated for patients suffering from disability due to:

    • degenerative, post-traumatic or rheumatoid arthritis; .
    • . avascular necrosis of the femoral condyle;
    • . post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy;
    • . moderate valgus, varus or flexion deformities;

    This device may also be indicated in the salvage of previously failed surgical attempts. This device is intended to be used with the 3DKnee System for cemented or uncemented applications.

    Device Description

    The Highly Cross-Linked Vitamin E UHMWPE (HXL VE) Tibial Inserts are manufactured from ultra high molecular weight polyethylene (UHMWPE) powder that is blended with pure liquid pharmaceutical grade alpha-tocopheral, compression molded and then highly cross-linked. The tibial inserts are available in 9 sizes (2- 12) and 5 thicknesses (9-19) and are provided in right and left orientations. The HXL VE Tibial Insert design is identical to the 3DKnee Tibial Insert cleared via K020114. This insert is intended to more closely match the kinematics of the knee, allowing some rotation along the medial condyle and increased congruency along the lateral condyle. The baseplate attachment mechanism is the same as the previously cleared 3DKnee System inserts.

    AI/ML Overview

    The provided document is a 510(k) summary for a medical device called "Highly Cross-Linked Vitamin E UHMWPE Tibial Insert." This document focuses on demonstrating substantial equivalence to previously cleared devices rather than presenting a study to prove acceptance criteria for a new, innovative device with unique performance claims.

    Therefore, many of the requested elements for a study proving acceptance criteria (like sample size for a test set, number of experts for ground truth, adjudication methods, MRMC studies, standalone performance, and ground truth for training sets) are not applicable to this type of regulatory submission. This document describes a device approval based on non-clinical testing demonstrating similarity to existing devices.

    Here's a breakdown of the available information based on your request:

    1. Table of Acceptance Criteria and Reported Device Performance

    This report does not define specific discrete "acceptance criteria" in the way a performance study for an AI algorithm or a novel diagnostic might. Instead, it relies on demonstrating that the new device's material properties, design, and indications for use are substantially equivalent to legally marketed predicate devices. The "reported device performance" is the outcome of various non-clinical tests showing these equivalencies.

    Test CategoryAcceptance Criteria (Implied)Reported Device Performance
    Mechanical Material CharacterizationComparable to predicate devices (E-Poly Tibial Bearings, K080528)All testing demonstrated substantial equivalence.
    (Tensile, Small Punch, Izod Impact, Crack Prog)
    Physical and Chemical CharacterizationComparable to predicate devices (E-Poly Tibial Bearings, K080528)All testing demonstrated substantial equivalence.
    (Oxidation Index, Compressive Modulus, etc.)
    Tibial Insert Peel-out StrengthComparable to predicate devicesAll testing demonstrated substantial equivalence.
    Wear TestingComparable to predicate devicesAll testing demonstrated substantial equivalence.
    BiocompatibilityComparable to predicate devicesAll testing demonstrated substantial equivalence.
    Design (size, thickness, configuration, dim.)Identical to 3DKnee Tibial Insert (K020114)Design is identical to the 3DKnee Tibial Insert (K020114).
    Indications for UseEquivalent to 3DKnee Tibial Insert (K020114)Indications for Use are equivalent.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: Not applicable. This was non-clinical testing of materials and device components, not a clinical study on patient data. The "sample size" would refer to the number of physical samples tested for each material or mechanical property. This specific number is not provided in the summary but would be detailed in the full test reports.
    • Data Provenance: Not applicable in the context of clinical data. The data originates from laboratory testing. It is neither retrospective nor prospective clinical data.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    Not applicable. Ground truth, in the context of this device, would be established by validated engineering and scientific testing standards and methodologies, not by expert medical consensus on clinical cases.


    4. Adjudication Method for the Test Set

    Not applicable. There's no clinical test set requiring adjudication in this submission.


    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study was not done. The document explicitly states: "Clinical Testing: None provided as a basis for substantial equivalence." This is a non-clinical submission.


    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study Was Done

    Not applicable. This is a physical medical device (an orthopedic implant), not an algorithm or AI system.


    7. The Type of Ground Truth Used

    For the non-clinical tests, the "ground truth" is based on:

    • Established material science properties.
    • Validated mechanical testing standards (e.g., for wear, strength, fatigue).
    • Chemical quantification methods.
    • Biocompatibility standards.
    • Direct comparison of design specifications to the predicate device.

    8. The Sample Size for the Training Set

    Not applicable. There is no "training set" as this is not an AI or machine learning device.


    9. How the Ground Truth for the Training Set Was Established

    Not applicable. There is no "training set" for this device.