510(k) Data Aggregation

    K Number
    K133314

    Validate with FDA (Live)

    Date Cleared
    2013-12-03

    (36 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The HARMONIC FOCUS® Shears + Adaptive Tissue Technology are indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired. The instrument can be used as an adjunct to or substitute for electrosurgery, lasers, and steel scalpels in general, otorhinolaryngologic (ENT), plastic, pediatric, gynecologic, exposure to orthopedic structures (such as spine and joint space) and other open procedures.

    Device Description

    The Ethicon Endo-Surgery HARMONIC FOCUS Shears + Adaptive Tissue Technology is a sterile, single-patient use surgical instrument consisting of a soft grip scissor handle housing assembly with two hand controls (MIN for minimum power level and MAX for maximum power level). The instrument's working length is 9 cm in length with a 16 mm active blade length. The instrument allows for the cutting and coagulation of vessels up to and including 5 mm in diameter.

    AI/ML Overview

    Acceptance Criteria and Study to Prove the Device Meets Acceptance Criteria

    The provided 510(k) summary for the HARMONIC FOCUS Shears + Adaptive Tissue Technology does not explicitly list acceptance criteria in a quantitative table format or a detailed study protocol for performance. However, based on the Performance Data section, the general acceptance criteria are:

    • Equivalence to the predicate device: The HARMONIC FOCUS Shears + Adaptive Tissue Technology device performance was equivalent to the predicate (HARMONIC FOCUS® Shears, K100597) in terms of safety and effectiveness.
    • Effective cutting and coagulation: The device effectively cuts and coagulates soft tissue and seals vessels up to 5 mm in diameter.
    • Biocompatibility: The device is biocompatible.
    • Electrical safety and EMC compliance: The device meets electrical safety and electromagnetic compatibility (EMC) standards.

    The study that proves the device meets these acceptance criteria is described as follows:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Performance GoalReported Device Performance
    Equivalence to PredicateOverall safety and effectiveness comparable to HARMONIC FOCUS® Shears (K100597)."The results demonstrate the HARMONIC FOCUS Shears + Adaptive Tissue Technology device performance was equivalent to the predicate." "The results of the bench testing and laboratory evaluations in an animal model demonstrate that the HARMONIC FOCUS Shears + Adaptive Tissue Technology are as safe and effective and perform as well as the identified legally marketed predicate devices for cutting and coagulating soft tissue and sealing vessels up to 5 mm in diameter, as measured in situ."
    Functional PerformanceEffective cutting and coagulation of soft tissue and vessels up to 5 mm."The results of those evaluations demonstrate that the HARMONIC FOCUS Shears + Adaptive Tissue Technology effectively cut and coagulated vessels 1 to 5mm in diameter." "The results of the bench testing and laboratory evaluations in an animal model demonstrate that the HARMONIC FOCUS Shears + Adaptive Tissue Technology are as safe and effective and perform as well as the identified legally marketed predicate devices for cutting and coagulating soft tissue and sealing vessels up to 5 mm in diameter, as measured in situ."
    Material SafetyBiocompatibility"Biocompatibility studies... were performed." (Implies positive outcome indicating compliance).
    Electrical SafetyElectrical safety compliance"electrical safety testing... were performed." (Implies positive outcome indicating compliance).
    EMC ComplianceElectromagnetic compatibility (EMC) compliance"EMC testing were performed." (Implies positive outcome indicating compliance).

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: Not explicitly stated for either bench testing or animal models. The document refers to "laboratory evaluations in an animal model" and "biocompatibility studies, electrical safety testing, and EMC testing" without specifying the number of samples or animals used.
    • Data Provenance: The studies were preclinical laboratory evaluations and non-clinical bench testing. The country of origin of the data is not specified but is typically internal to the company or contracted labs. The studies were prospective in nature, designed specifically to test the new device.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    • Not applicable. This submission does not involve human clinical data or expert visual/interpretive assessment of medical images/data. The "ground truth" for this device's performance relies on objective measurements from bench testing (e.g., power output, blade temperature, vessel sealing strength, cutting speed) and direct observation/assessment in animal models.

    4. Adjudication Method for the Test Set

    • Not applicable. As the "ground truth" for performance was based on objective measurements and direct observation in controlled environments (bench and animal labs), there was no need for an adjudication method by human experts for the test set.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No. A Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. The submission explicitly states: "This premarket notification does not rely on data from human clinical trials to demonstrate substantial equivalence. Clearance was based on non-clinical and preclinical testing." This type of study is typically used for diagnostic devices involving human readers.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    • Yes, in essence. The performance studies described (biocompatibility, electrical safety, EMC, bench testing, and animal model evaluations) assess the device's inherent mechanical and electrical functionality, including its "Adaptive Tissue Technology" algorithm, in a standalone manner without human subjective input affecting the outcome of the performance metrics. The algorithm's function (reducing power, providing a secondary tone) is evaluated by observing its effect on the physical performance of the instrument.

    7. Type of Ground Truth Used

    • Objective Measurements and Direct Observation/Assessment:
      • Bench Testing: Mechanical properties, electrical characteristics, thermal profiles, cutting efficacy, coagulation performance (e.g., burst pressure for sealed vessels).
      • Animal Models: In vivo assessment of cutting and coagulation effectiveness on vessels of specific diameters (1-5mm), observation of acute and 30-day chronic healing responses, and assessment of thermal injury.

    8. Sample Size for the Training Set

    • Not applicable/Not specified. This device uses an "Adaptive Tissue Technology algorithm" but the 510(k) summary does not indicate that this algorithm was "trained" in the typical machine learning sense using a specific dataset. It refers to "power output algorithm that is utilized by the devices" and "algorithm parameters stored on the device EEPROM." It is more likely a rule-based or control algorithm designed based on engineering principles and validated through the performance studies rather than a machine learning model requiring a discrete "training set."

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable. As described in section 8, a "training set" in the context of machine learning is not implied or specified for this device's algorithm. The "ground truth" for developing the algorithm's parameters would have been established through engineering design, material science, and possibly iterative prototyping and testing to optimize the power delivery for different tissue conditions.
    Ask a Question

    Ask a specific question about this device

    K Number
    K100597

    Validate with FDA (Live)

    Date Cleared
    2010-04-07

    (36 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    All
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The HARMONIC FOCUS™ Shears are indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired. The instruments can be used as an adjunct to or substitute for electrosurgery, lasers, and steel scalpels in general, otorhinolaryngologic (ENT), plastic, pediatric, gynecologic, urologic, exposure to orthopedic structures (such as spine and joint space), and other open procedures.

    Device Description

    The Harmonic FOCUS™ Curved Shears is a sterile, single patient use instrument consisting of a soft grip scissor handle housing assembly with two hand controls (MIN for minimum power level and MAX for maximum power level). The instrument has a curved blade and clamp arm with Teflon pad. The instruments working length is 9cm with a 16mm active blade length. The FOCUS instrument allows for the cutting and coagulation of vessels up to and including 5mm in diameter. The Harmonic FOCUS Shears are designed for use with a generator capable of providing electrical energy to the FOCUS device and with a handpiece that converts the electrical energy to mechanical energy.

    AI/ML Overview

    This document is a 510(k) premarket notification for the Harmonic FOCUSTM shears, specifically requesting a modification to the Indications for Use statement to include otorhinolaryngology procedures. It is not a study proving device performance against acceptance criteria in the manner requested (e.g., in terms of sensitivity, specificity, or other quantitative performance metrics usually associated with AI/software devices).

    The device is a surgical instrument, and its performance evaluation for this 510(k) relies on showing substantial equivalence to previously cleared predicate devices, rather than a de novo clinical study with specific acceptance criteria and performance reporting as one might see for diagnostic AI.

    Therefore, much of the requested information cannot be directly extracted from the provided text. I will address what can be inferred and explicitly state what is not available.

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state acceptance criteria in the form of quantitative performance metrics (e.g., a specific success rate, accuracy, etc.) for the device itself or for its application in otorhinolaryngology. Instead, the "acceptance criteria" for this 510(k) submission are based on demonstrating substantial equivalence to predicate devices.

    The key performance claim related to the device's function is:

    Acceptance Criteria (Implied)Reported Device Performance
    Ability to seal vessels"The Harmonic FOCUS shears device will seal vessels up to and including 5mm in diameter."
    Safety and effectiveness in otorhinolaryngology (ENT) procedures"An assessment of published clinical literature demonstrates that there is a considerable body of knowledge and experience that show the use of ultrasonic Harmonic technology in otorhinolaryngological (ENT) procedures is as safe and effective as predicate technology for use."

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided. The submission relies on prior performance data (K063192) and clinical literature assessment for the safety and effectiveness in ENT procedures, rather than a new test set for this specific 510(k) modification.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not applicable/provided. There was no new "test set" in the context of diagnostic performance that would require expert adjudication. The "ground truth" for the device's performance (e.g., vessel sealing capability) would have been established through engineering tests or animal/cadaver studies during the predicate device's clearance. For the literature review, the "experts" are the authors of the published clinical literature.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not applicable/provided for the reasons stated above.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not applicable. This device is a surgical instrument, not an AI or diagnostic software that would involve human "readers" or AI assistance.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This information is not applicable. This is not an algorithm or AI device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" for the claims in this submission is implicit:

    • Vessel sealing capability: Likely established through pre-clinical (e.g., in vitro, cadaver, or animal) studies, along with standard engineering and functional testing.
    • Safety and effectiveness in ENT: Established through published clinical literature on ultrasonic Harmonic technology, comparing it to predicate technologies. This would primarily rely on outcomes data reported in those studies (e.g., bleeding control, thermal injury, surgical efficacy, patient safety).

    8. The sample size for the training set

    This information is not applicable/provided. This is not an AI/ML device that uses a "training set."

    9. How the ground truth for the training set was established

    This information is not applicable/provided for the reasons stated above.

    Summary of Approach for This 510(k):

    The manufacturer's strategy for this 510(k) was to demonstrate substantial equivalence to existing, legally marketed predicate devices. This involves showing that the modified device has the "same intended use, the indications for use, the technological characteristics and the energy requirements of the systems." For the specific inclusion of otorhinolaryngology, they relied on existing "clinical literature" to show that ultrasonic Harmonic technology (the core technology) is already proven safe and effective in this field. They explicitly state, "The design of the Harmonic FOCUS Shears is essentially unchanged and the performance data provided in K063192 is still applicable to the device."