Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K232820

    Validate with FDA (Live)

    Date Cleared
    2024-06-04

    (265 days)

    Product Code
    Regulation Number
    878.4040
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    HALYARD* FLUIDSHIELD* 1 Fog-Free Surgical Mask with So Soft Lining (28806) is intended to be worn to protect both the patient and healthcare personnel from transfer of microorganisms, body fluids, and particulate material. These face masks are intended for use in infection control practices to reduce the potential exposure of the wearer to blood and body fluids. The HALYARD* FLUIDSHIELD* 1 Fog-Free Surgical Mask with So Soft Lining (28806) is a single use, disposable device, provided non-sterile.

    Device Description

    The subject device is an ASTM F2100 Level 1 (green in color) Surgical Mask. The ASTM F2100 Level 1 Surgical Mask family of products are a three-layer mask, constructed of well-known non-woven materials used in facial protection. The Surgical Masks are provided with ties and a malleable nosepiece. The HALYARD* FLUIDSHIELD* 1 Fog-Free Surgical Mask with So Soft Lining (28806) is provided with fog-free foam. These masks are single use, disposable devices, provided non-sterile.

    AI/ML Overview

    This information describes the performance testing for a medical device (a surgical mask), not an AI/ML device. Therefore, many of the requested criteria regarding AI/ML studies are not applicable.

    Here's the breakdown of the provided information:

    1. A table of acceptance criteria and the reported device performance

    PurposeTestAcceptance CriteriaResult
    Face Mask PerformanceASTM F2100ASTM F2100 Level 1Pass
    Bacterial Filtration EfficiencyASTM F2101≥95%Pass
    Particulate Filtration EfficiencyASTM F2299≥95%Pass
    Differential PressureEN 14683<5.0 mmH2O/cm²Pass
    Fluid ResistanceASTM F186280 mmHgPass
    Flammability16 CFR Part 1610Class 1Pass
    Face Mask PerformanceEN 14683EN 14683 Type IIPass
    Bacterial Filtration EfficiencyEN 14683≥98%Pass
    Differential PressureEN 14683<40 Pa/cm²Pass
    Microbial CleanlinessISO 11737-1≤30 cfu/gPass
    BiocompatibilityISO 10993Pass
    CytotoxicityISO 10993-5Non-cytotoxicPass
    SensitizationISO 10993-10Non-sensitizingPass
    IrritationISO 10993-10Non-irritantPass

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
    The document does not specify the sample sizes used for each test. The tests are non-clinical performance tests on the physical mask, not data-driven tests.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
    Not applicable. These are physical performance tests that follow standardized test methods, not expert-adjudicated ground truth for AI/ML performance.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
    Not applicable. This is not an AI/ML device requiring adjudication of results.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
    Not applicable. This is a surgical mask, not an AI-assisted diagnostic device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
    Not applicable. This is not an AI/ML algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)
    The "ground truth" for these tests is defined by the specific, recognized international and national standards (ASTM, EN, ISO, 16 CFR Part 1610) that outline the methodologies and acceptance criteria for evaluating the physical and biological properties of surgical masks.

    8. The sample size for the training set
    Not applicable. This is not an AI/ML device, so there is no training set.

    9. How the ground truth for the training set was established
    Not applicable. There is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1