510(k) Data Aggregation

    K Number
    K163448

    Validate with FDA (Live)

    Device Name
    GrindCare System
    Date Cleared
    2017-09-01

    (267 days)

    Product Code
    Regulation Number
    882.5050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The GrindCare System is indicated to aid in the evaluation and management of sleep bruxism by reducing the temporalis muscle EMG activity during sleep.

    Device Description

    The GrindCare System is a portable electromyographic (EMG), electrical stimulation, and biofeedback device. It consists of a Sensor that is adhered to the skin over the temporalis muscle by means of an adhesive, disposable, single-use GelPad. The System also includes a Docking Station, USB Cable, and Power Adaptor. The Sensor and Docking Station record and store EMG activity data, which is transferred from the Docking Station to the GrindCare Mobile App, which allows the user to review grinding and stimulation data and enter diary notes. The Sensor uses EMG to sense contraction of the temporalis muscle that is associated with bruxing events. In response to the EMG-measured contraction, it delivers mild electrical stimulation that is intended to relax the muscle and inhibit the bruxing event.

    AI/ML Overview

    The provided document describes the GrindCare System, a biofeedback device intended to aid in the evaluation and management of sleep bruxism by reducing temporalis muscle EMG activity during sleep. The substantial equivalence determination is based on a comparison to a predicate device (GrindCare, K092675), which is a previous version of the same system.

    Based on the provided text, here's a breakdown of the requested information:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly present a "table of acceptance criteria" in the typical sense with pass/fail thresholds. Instead, it describes various performance tests and compares the subject device's functionality to that of the predicate device. The underlying acceptance criterion for each aspect is essentially that the subject device's performance is equivalent to or better than the predicate device, or that it meets relevant safety and performance standards.

    Acceptance Criteria (Implied)Reported Device Performance and Evidence
    Functional Equivalence to Predicate Device:
    - Wireless Charging FunctionalityPerformance testing demonstrated the functionality of the wireless charging. (p. 6)
    - Communication Functionality (Sensor to Docking Station, Docking Station to App)Performance testing demonstrated the functionality of communication between the Sensor and the Docking Station and between the Sensor and the GrindCare App. (p. 7)
    - Data Storage and Transfer FunctionalityPerformance testing demonstrated the functionality of the data storage and transfer. (p. 7) The Docking Station can store up to 5 years of data. (p. 7)
    - PCB Functionality (despite size reduction)Performance testing demonstrated the functionality of the PCB. (p. 7)
    - Microprocessor Functionality (equivalent to predicate)Performance testing demonstrated the functionality of the microprocessor. (p. 7) No differences impact functionality or performance. (p. 7)
    - GrindCare App Functionality (for data viewing)Performance testing demonstrated the functionality of the GrindCare App. (p. 7)
    - Equivalent Grind Detection Algorithm PerformancePerformance testing demonstrated equivalent performance of the grind detection algorithm to the predicate device. (p. 7) The device still provides the identical stimulation signal. (p. 7)
    Clinical Effectiveness:
    - Reduction in EMG events per hourThe clinical study demonstrated that the modified detection algorithm decreased the number of EMG events per hour by 32.45% over baseline. (p. 8) The device demonstrated a statistically significant reduction on the number of EMG events per hour on a representative patient population. (p. 8)
    Safety and Compliance with Standards:
    - Electrical Safety (IEC 60601-1, 60601-2-40)Complies with IEC 60601-1: 2005 + CORR1:2006 + CORR.2:2007 + AM1:2012 and IEC 60601-2-40: 1998. (p. 7-8)
    - Usability (IEC 60601-1-6, 60601-1-11)Complies with IEC 60601-1-6: 2010 + A1:2013 and IEC 60601-1-11: 2010. (p. 8) Usability testing demonstrated users and prescribers could perform tasks. (p. 8)
    - Electromagnetic Compatibility (IEC 60601-1-2)Complies with IEC 60601-1-2 Edition 3: 2007-03. (p. 8)
    - Battery Safety and Certification (IEC 62133)Complies with IEC 62133 Edition 2.0: 2012-12. (p. 8)
    - Wireless CoexistenceTesting demonstrated wireless coexistence with other FR transmitters common in the home environment. (p. 8)
    - Biocompatibility of Gelpad (ISO 10993-5, 10993-10)Complies with ISO 10993-5:2009 and ISO 10993-10: 2010. (p. 8)
    - Shelf Life (GelPads 24 months)Shelf life testing demonstrated the device continues to meet performance specifications for the 24-month shelf life of the gelpads. (p. 8)

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Test Set Sample Size: The document states that the clinical data demonstrated a statistically significant reduction in EMG events per hour "on a representative patient population." However, the specific sample size for this clinical study (test set) is not provided in the document.
    • Data Provenance: The document does not specify the country of origin of the data or whether the clinical study was retrospective or prospective. It is implied to be a conducted study for the purpose of this submission ("The clinical study demonstrated...").

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not provided in the document. The device automates the detection of EMG activity and applies stimulation. The "ground truth" for the clinical study appears to be the measured EMG activity itself, which the device processes. There is no mention of human experts interpreting raw EMG data or establishing a "ground truth" for bruxing events in the test set, beyond the device's own detection.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not applicable as the document does not describe a scenario involving multiple human readers or interpretations needing adjudication for the test set. The clinical study seems to be based on the device's ability to measure and respond to EMG activity.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: No, an MRMC comparative effectiveness study was not explicitly described or referenced. The study described focuses on the device's direct effect on EMG activity reduction, not on how human readers (e.g., clinicians) perform better with or without AI assistance from this specific device. The device is a biofeedback system that directly interacts with the patient, not an AI diagnostic aid for human readers.
    • Effect Size of Human Reader Improvement: This is not applicable as an MRMC study was not described. The provided effect size of 32.45% reduction is in EMG events due to the device's intervention, not an improvement in human reader performance.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Yes, in essence, the "clinical study" section (p. 8), which demonstrated the 32.45% reduction in EMG events, represents the standalone performance of the algorithm (as implemented in the device) in reducing temporalis muscle EMG activity. The device is designed to automatically detect and respond to bruxing events without continuous human intervention during the night.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    The "ground truth" for the clinical study described appears to be the measured temporalis muscle EMG activity itself. The device's performance is measured by its ability to reduce this objectively measurable physiological activity. The "grind threshold" is automatically calculated based on background noise (p. 7), suggesting an automated, objective measure rather than subjective expert consensus or pathology results.

    8. The sample size for the training set

    The document does not specify the sample size for any training set. Given the device is an evolution of a predicate with a "modified detection algorithm," it's possible such data was used, but it is not mentioned in this summary.

    9. How the ground truth for the training set was established

    This information is not provided in the document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K113677

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2012-04-05

    (113 days)

    Product Code
    Regulation Number
    890.1375
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The GRINDCARE MEASURE device is indicated to aid in the evaluation of nocturnal bruxism by measuring the temporalis muscle EMG activity during sleep.

    Device Description

    GRINDCARE MEASURE is a portable electromyographic (EMG) monitoring device. The device consists of the recorder, a tri-polar electrode and a docking station. The electrode is placed on the forehead with three integrated electrodes in close connection to the temporalis muscle by means of a double-adhesive patch incorporating three conductive gelpads and connected to the recorder. The device records EMG activity and processes the signal to detect a particular activity (tooth grinding/clenching). It uses EMG to sense contraction of the temporalis muscle that is associated with bruxing events. The EMG events are logged and stored on the recorder. This data can be transferred to a healthcare professional's PC for assessment of the user's bruxism.

    AI/ML Overview

    The GRINDCARE MEASURE device underwent performance testing to ensure it met design specifications and complied with relevant standards. The provided document does not contain details about specific acceptance criteria related to clinical performance (e.g., sensitivity, specificity for bruxism detection) or a clinical study that proves the device meets such criteria. Instead, it references compliance with general electrical safety and electromagnetic compatibility standards, and that its performance was previously tested for the predicate device (K092675).

    Here's an analysis of the provided information:

    1. Table of Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria CategorySpecific Criteria (from document)Reported Device Performance
    Electrical SafetyIEC 60601-1: Medical Electrical Equipment Part 1: General Requirements for SafetyMeets requirements
    EM CompatibilityIEC 60601-1-2: Medical Electrical Equipment Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and TestsMeets requirements
    Electromyographs SafetyIEC 60601-2-40: Medical Electrical Equipment Part 2-40: Particular Requirements for the Safety of Electromyographs and Evoked Response EquipmentMeets requirements
    RF FunctionalityFCC CFR 47 Part 15, Subpart CMeets requirements
    Bouxism DetectionNot specified directly in terms of performance metrics like sensitivity/specificity for bruxism events."records EMG activity and processes the signal to detect a particular activity (tooth grinding/clenching)." "uses EMG to sense contraction of the temporalis muscle that is associated with bruxing events."

    2. Sample Size for Test Set and Data Provenance:

    • Sample Size: Not explicitly stated. The document refers to "device testing" and meeting "design specifications" and existing standards, but does not detail a clinical test set or its size for bruxism detection performance.
    • Data Provenance: Not specified. Based on the manufacturer's location (Denmark) and the referenced standards, it's likely testing was conducted to international standards. Whether a dedicated clinical study with human subjects for the GRINDCARE MEASURE was performed, and its nature (retrospective/prospective, country of origin), is not detailed.

    3. Number of Experts and Qualifications for Ground Truth (Test Set):

    • This information is not provided. The document focuses on technical and electrical safety standards rather than clinical performance validation against expert-established ground truth for bruxism diagnosis.

    4. Adjudication Method for Test Set:

    • This information is not provided. As there's no detailed clinical study described, there's no mention of an adjudication method for a test set.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    • No, a MRMC comparative effectiveness study is not mentioned. The document does not describe any human-in-the-loop performance evaluation or comparison of human readers with and without AI assistance for the GRINDCARE MEASURE. The device is a diagnostic tool for measuring EMG activity, not an assistive AI for human interpretation.

    6. Standalone (Algorithm Only) Performance Study:

    • Yes, in spirit, the device's ability to detect bruxing events represents a standalone performance. The document states: "It uses EMG to sense contraction of the temporalis muscle that is associated with bruxing events. The EMG events are logged and stored on the recorder." This implies the device's internal processing (algorithm) identifies these events independently. However, specific standalone performance metrics (e.g., accuracy, sensitivity, specificity) against a clinical ground truth for bruxing events are not provided. The "performance data" section primarily lists compliance with technical standards.

    7. Type of Ground Truth Used:

    • For the technical and safety standards, the ground truth would be the parameters defined by the respective IEC and FCC standards. For the detection of "bruxing events," the document implies that the EMG signals indicating muscle contraction serve as the basis for detection. However, it does not specify how the accuracy of this detection itself was validated against a gold standard for bruxism (e.g., polysomnography with video, expert observation, or clinical diagnosis).

    8. Sample Size for Training Set:

    • This information is not provided. The document does not describe the development of an AI algorithm based on a training set for bruxism detection. The device "processes the signal to detect" events, but details on how this processing was developed or "trained" are absent.

    9. How Ground Truth for Training Set Was Established:

    • This information is not provided as there is no mention of a training set for an AI algorithm in the provided text.
    Ask a Question

    Ask a specific question about this device

    K Number
    K092675

    Validate with FDA (Live)

    Device Name
    GRINDCARE
    Manufacturer
    Date Cleared
    2010-03-03

    (183 days)

    Product Code
    Regulation Number
    882.5050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The GRINDCARE device is indicated to aid in the evaluation and management of nocturnal bruxism by reducing the temporalis muscle EMG activity during sleep.

    Device Description

    GRINDCARE is a portable electromyographic (EMG) and electrical stimulation device. The device consists of a stimulator, a docking station and a tri-polar electrode. The electrode is placed on the forehead with three integrated electrodes in close connection to the temporalis muscle by means of a double-adhesive patch incorporating three conductive gelpads and connected to the stimulator. The device records EMG activity and processes the signal to detect a particular activity (tooth grinding/clenching). It uses EMG to sense contraction of the temporalis muscle that is associated with bruxing events. In response to the EMG-measured contraction, it delivers mild electrical stimulation that is intended to relax the muscle and inhibit the bruxing event. The EMG events are logged and stored on the device. This data can be transferred to a healthcare professional's PC for assessment of the user's bruxism.

    AI/ML Overview

    The provided text refers to a 510(k) summary for the GRINDCARE device, a biofeedback device for nocturnal bruxism. However, the document provided does not contain detailed acceptance criteria or a study that rigorously proves the device meets specific performance criteria beyond general conformity to standards.

    Here's an analysis based on the information available:

    1. A table of acceptance criteria and the reported device performance

    The document does not provide a table of explicit, quantitative acceptance criteria for the device's performance in reducing temporalis muscle EMG activity, nor does it report specific performance metrics against such criteria.

    The "Performance Data" section states:
    "Device testing was performed and the device was shown to meet its design specifications."
    "Device performance will also be in conformance to the following standards prior to marketing: IEC 60601-1, IEC 60601-1-2, IEC 60601-2-10, IEC 60601-2-40."
    "RF function of the device meets requirements of FCC CFR 47 Part 15, Subpart C."

    These statements indicate that the device met internal design specifications and general safety/EMC standards, but they do not provide specific clinical performance metrics (e.g., % reduction in EMG activity, sensitivity, specificity for bruxing events). The "clinical data are provided to demonstrate safety and effectiveness" but the details of this clinical data (acceptance criteria, results) are not present in this summary.

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    This information is not provided in the given 510(k) summary. The document mentions "Clinical data are provided to demonstrate safety and effectiveness," but it does not specify the sample size, type of study (prospective/retrospective), or data provenance for any clinical test set.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    This information is not provided in the given 510(k) summary. Given the nature of the device (EMG for bruxism), ground truth for bruxism events would typically involve clinical assessment or expert interpretation of polysomnography/EMG recordings, but no details are given.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    This information is not provided in the given 510(k) summary.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This type of study is not applicable to the GRINDCARE device as described. The GRINDCARE is an electromyographic and electrical stimulation device that directly senses and treats bruxism; it is not an AI-assisted diagnostic tool for human readers/clinicians to interpret. Therefore, an MRMC study comparing human readers with and without AI assistance is not relevant to this device.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    The device itself operates as a standalone system to detect EMG activity and deliver stimulation. The text states: "It uses EMG to sense contraction of the temporalis muscle that is associated with bruxing events. In response to the EMG-measured contraction, it delivers mild electrical stimulation..." This describes the device's standalone operation. However, no specific performance metrics for this standalone detection and stimulation (e.g., accuracy of bruxism detection, effectiveness of stimulation) are detailed in this summary.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The document does not explicitly state the type of ground truth used for any clinical data that was provided. For a bruxism device, ground truth often involves polysomnography with EMG recordings, expert clinical diagnosis, or patient-reported outcomes, but this is not specified here.

    8. The sample size for the training set

    This information is not provided in the given 510(k) summary. The device uses signal processing to detect events, which implies some form of training or calibration, but details are absent.

    9. How the ground truth for the training set was established

    This information is not provided in the given 510(k) summary.

    In summary, the provided 510(k) document is a high-level summary that indicates conformity to general safety and design standards and states that clinical data was provided to demonstrate safety and effectiveness for substantial equivalence. However, it explicitly lacks the detailed clinical study design, acceptance criteria, test set/training set sizes, ground truth establishment methods, and specific performance results that would answer most of your detailed questions. These details would typically be found in the full 510(k) submission, not in this brief summary.