510(k) Data Aggregation

    K Number
    K073440

    Validate with FDA (Live)

    Device Name
    FOUNDATION CAGE
    Manufacturer
    Date Cleared
    2008-04-24

    (139 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Foundation™ Cervical Interbody Devices are indicated for use in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one disc level. DDD is defined as discogenic pain with degeneration of the disc confirmed by patient history and radiographic studies. Foundation™ Cervical implants are used to facilitate intervertebral body fusion in the cervical spine and are placed via an anterior approach at the C3 to C7 disc levels using autograft bone. Foundation Cervical implants are to be used with supplemental fixation. Patients should have at least six (6) weeks of non-operative treatment prior to treatment with an intervertebral cage.

    The Foundation™ Lumbar Interbody Devices are indicated for intervertebral body fusion procedures in skeletally mature patients with degenerative disc disease (DDD) of the lumbar spine at one or two contiguous levels from L2-S1. DDD is defined as discogenc ne inn with degeneration of the disc confirmed by history and radiographic studies. These DDD patients may also have up to Grade I spondylolisthesis or retrolisthesis at the involved level(s). Fourdation™ Lumbar implants are to be used with autogenous bone graft and implanted via an open anterior or posterior approach. Foundation™ Lumbar implants are to be used with supplemental fixation. Patients should have at least six (6) months of non-operative treatment prior to treatment with an intervertebral cage.

    Device Description

    The interbody fusion with autogenous bone graft solves and provides a logical solution for discal diseases once the movement of the vertebral segment is eliminated. The theoretical principles of the interbody cages are based on the following foundations:

    • Mechanical function, allows restoration of the intervertebral disc height and immediate 1. stability of the mobile segments.

    • Biological function, related to the autogenous bone graft introduction into and around 2. the cage, facilitates the interbody fusion.
      The posterior Foundation Cage was developed as an implant for the posterior stabilization of the lumbar spinal column with the technique of Posterior Lumbar Interbody Fusion (PLIF).

    The anterior Foundation Cage was developed as an implant for the posterior stabilization of the lumbar spinal column with the technique of Anterior Lumbar Interbody Fusion (ALIF),

    The Foundation Cervical cage is a trapezoidal shape footprint for central placement in the vertebral body from an anterior approach.

    Materials:

    PEEK Optima® conforming to ASTM F2026

    AI/ML Overview

    This 510(k) summary for the Foundation Interbody Devices (K073446/K073440) does not describe a study involving software performance or AI evaluation.

    Instead, it details a medical device (intervertebral body fusion device), its intended use, materials, and substantial equivalence to previously marketed devices. The "Summary of Nonclinical Tests" section refers to mechanical strength testing of the physical implant, not a clinical study to evaluate diagnostic or therapeutic performance in a human population, nor any AI or software component.

    Therefore, I cannot fulfill your request for information about acceptance criteria for device performance, sample sizes for test/training sets, expert qualifications, or MRMC studies, as these aspects are not present in the provided document for this type of medical device submission.

    The only "acceptance criteria" mentioned in the document relate to the physical device's mechanical properties:

    1. Table of Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (Mechanical Strength)Reported Device Performance
    Meet required mechanical strengthsTests performed according to ASTM F2077 indicate that the Foundation Interbody Devices meet required mechanical strengths.

    The rest of the requested information is not applicable or available in the provided text, as it pertains to AI/software evaluation studies, which are not described for this physical interbody fusion device.