Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K964804

    Validate with FDA (Live)

    Device Name
    FLEXILOG LS
    Date Cleared
    1997-08-06

    (250 days)

    Product Code
    Regulation Number
    876.1725
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The FLEXILOG LS is used for the location of the lower and/or upper esophageal sphincter and the measuring of the nares to esophageal sphincter distance. This procedure being carried out prior to the accurate placement of a pH sensitive catheter for an ambulatory pH study to quantify gastroesophageal reflux.

    The FLEXILOG LS, Esophagea1 Sphinctor Locator, is to be used for the manometric location of the lower and upper esophageal sphincters. That is the measurement of the distance from the nares to the sphincter.

    Device Description

    The FLEXILOG LS is a single channel, pressure monitoring system comprising of a module of electronics that provides transducer excitation, amplification and transmission of the signal to a computer via an optically isolated RS232 connector. The pressure signal is displayed on the computer VDU via a Microsoft Windows display program. The program does not provide any analysis or data saving options.

    The electronics module is designed to be compatible with catheter tip perfused pressure transducers currently available in the US market.

    AI/ML Overview

    The provided document is a 510(k) premarket notification for the FLEXILOG LS Esophageal Sphincter Detector. It does NOT contain information about acceptance criteria or a study proving that a device meets such criteria.

    The document includes:

    • Trade Name: FLEXILOG LS
    • Common Name: Esophageal Sphincter Detector
    • Classification Name: Monitor, esophageal motility and tube
    • Indications for Use: For the location of the lower and/or upper esophageal sphincter and the measuring of the nares to esophageal sphincter distance, prior to accurate placement of a pH sensitive catheter for an ambulatory pH study to quantify gastroesophageal reflux.
    • Description: A single-channel pressure monitoring system that provides transducer excitation, amplification, and signal transmission to a computer via an optically isolated RS232 connector. The pressure signal is displayed on a computer VDU without analysis or data saving options.
    • Technological Characteristics: Similar to predicate devices (FLEXILOG LS Lower Esophageal Sphincter Detector, RMS III, the LES Locator, Digitrapper MKIII, Digitrapper MD) but with electronics in a standalone box, not integrated with ambulatory pH recorders, and not requiring connection to a pH recorder. Displays data on a computer screen.
    • Testing: Only a general statement is provided: "The FLEXILOG LS has been shown to accurately measure and display pressure." No specific study details, methodology, sample sizes, ground truth establishment, or acceptance criteria are given.
    • Predicate Devices: Oakfield Instruments Limited, FLEXILOG LS; Sandhill Medical Inc., RMS III; Biolab, The LES Locator; Synectics Medical Limited, Digitrapper MKIII; Synectics Medical Limited, Digitrapper MD PC Polygraph HR.

    Therefore, I cannot provide the requested table or answer the specific questions about acceptance criteria, study details, sample sizes, ground truth, or MRMC studies, as this information is not present in the provided text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K961895

    Validate with FDA (Live)

    Date Cleared
    1996-11-04

    (172 days)

    Product Code
    Regulation Number
    876.1725
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The FLEXILOG LS is used for the location of the lower esophageal sphincter and the measuring of the nares to lower esophageal sphincter distance. This procedure being carried out prior to the accurate placement of a pH sensitive catheter for an ambulatory pH study to quantify gastroesophageal reflux.

    Device Description

    The FLEXILOG LS is a single channel, pressure monitoring system comprising of a module of electronics that provides transducer excitation, amplification and transmission of the signal to a computer via an optically isolated RS232 connector. The pressure signal is displayed on the computer VDU via a Microsoft Windows display program. The program does not provide any analysis or data saving options. The electronics module is designed to be compatible with catheter tip and water perfused pressure transducers currently available in the US market.

    AI/ML Overview

    This document is a 510K submission for the FLEXILOG LS device, a Lower Esophageal Sphincter Detector. The provided text outlines the device's description, indications for use, and technological characteristics, along with a claim of substantial equivalence to predicate devices. However, it does not contain the detailed study information required to answer your questions about acceptance criteria, specific performance metrics, sample sizes, ground truth establishment, or specialized studies like MRMC or standalone performance evaluations.

    The only statement related to performance and testing is: "The FLEXILOG LS has been shown to accurately measure and display pressure." This sentence is too vague to extract specific acceptance criteria or study details.

    Therefore,Based on the provided text, I cannot answer your questions as the document does not contain the detailed study results, acceptance criteria table, sample sizes, ground truth information, or specific study types (e.g., MRMC, standalone) you are looking for. The document only states that "The FLEXILOG LS has been shown to accurately measure and display pressure," which is a general claim and not specific performance data.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1