510(k) Data Aggregation

    K Number
    K071687

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2008-08-07

    (416 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Family of IRIDEX® IQ Laser Systems (IQ 532 [532nm], IQ 577 [577nm], IQ 630-670 [630nm-670nm], IQ 810 [810nm]) and the hand pieces, delivery devices & accessories that are used with them to deliver laser energy in either CW-pulse, MicroPulse™,or LongPulse™ mode. Intended for soft and fibrous tissue, including osseous tissue incision, excision, coagulation, vaporization, ablation and vessel hemostasis in the medical specialties of , dermatology, ear, nose and throat (ENT)/ otolaryngology, and ophthalmology as follows:

    532 nm
    Dermatology
    · Pigmented Skin Lesions
    · Vascular Lesions
    Ear. Nose, and Throat (ENT)/ Otolaryngology
    Otosclerotic Hearing loss and/or diseases of the inner ear:
    · Stapedectomy
    · Stapedotomy
    · Myringotomies
    Lysis of Adhesions
    · Control of Bleeding
    · Removal of Acoustic Neuromas
    " Soft tissue Adhesion in Micro/Macro Otologic Procedures
    Ophthalmology
    Indicated for retinal photocoagulation, laser trabeculoplasty, iridotomy, iridoplasty including:
    · Retinal photocoagulation (RPC) for the treatment of

    Diabetic retinopathy, including:
    Nonproliferative retinopathy
    Macular edema
    Proliferative retinopathy
    Retinal tears and detachments
    Lattice degeneration
    Age-related macular degeneration (AMD)
    Retinopathy of prematurity
    Sub-retinal (choroidal) neovascularization
    Central and branch retinal vein occlusion
    · Laser trabeculoplasty, iridotomy, iridoplasty for the treatment of glaucoma, including
    Primary open angle/Closed angle

    577nm
    Dermatology:
    · Treatment of Vascular and pigmented lesions
    Ophthalmology:
    Indicated for use in photocoagulation of both anterior and posterior segments including:
    Retinal photocoagulation, panretinal photocoagulation and intravitreal ● endophotocoagulation of vascular and structural abnormalities of the retina and choroids including :

    proliferative and nonproliferative diabetic retinopathy;
    choroidal neovascularization;
    branch retinal vein occlusion;
    age-related macular degeneration
    retinal tears and detachments
    retinopathy of prematurity
    Iridotomy, iridectomy and trabeculoplasty in angle closure glaucoma and open angle . Glaucoma

    630 - 670nm
    Ophthalmology:
    Indicated for use in photocoagulation of both anterior and posterior segments including:
    Retinal photocoagulation, panretinal photocoagulation and intravitreal . endophotocoagulation of vascular and structural abnormalities of the retina and choroid including:

    proliferative and nonproliferative diabetic retinopathy;
    choroidal neovascularization;
    branch retinal vein occlusion;
    age-related macular degeneration
    retinal tears and detachments
    retinopathy of prematurity
    Iridotomy, iridectomy and trabeculoplasty in angle closure glaucoma and open . angle glaucoma

    810nm
    Opthalmology:
    Indicated for retinal photocoagulation, laser trabeculoplasty, transscleral cyclophotocoagulation, transscleral retinal photocoagulation, iridotomy, including the following:
    · Retinal photocoagulation for the treatment of:

    Diabetic retinopathy including;
    Nonproliferative retinopathy
    Macular edema
    Proliferative retinopathy
    Retinal Tears, Detachments and Holes
    Lattice degeneration
    Age-related macular degeneration (AMD) with choroidal neovascularizations (CNV)
    Retinopathy of prematurity
    Sub-retinal (choroidal) neovascularization
    Central and Branch Retinal Vein Occlusion
    Laser Trabeculoplasty, Iridotomy, Transscleral Cyclophotocoagulation (TSCPC) . for the treatment of glaucoma, including;
    Primary open angle
    Closed angle
    Refractory Glaucoma (recalcitrant/uncontrolled)

    Device Description

    The Family of IRIDEX IQ Laser Systems is comprised of the following main components:
    Main console containing the major electrical components, including: .
    A Control Panel including control knobs (power, interval, duration or software assigned function), treat/standby button, and display;
    Two delivery device fiber-optic connector ports (only one active at a time); A
    A LIO illumination connection:
    Smart key port for detecting/operating safety filters and/or accessory A identification:
    A Emergency stop switch:
    A Kev switch:
    Connector ports for the footswitch, remote control, and power cord; A
    A treatment Footswitch (either wired, wireless, or wireless with PowerAdjust); .
    A Wired Remote Control that duplicates the control panel; .
    Delivery Accessories including OtoProbe handpieces, EndoProbe handpieces, . G-Probe and DioPexy Probe Handpieces, Dermatology Handpieces, Microscope Adapters, and Laser Indirect Ophthalmoscopes.
    . Optional Cart/Stand

    AI/ML Overview

    The provided 510(k) summary for the Family of IRIDEX IQ Laser Systems (K071687) does not contain information related to acceptance criteria or a study demonstrating the device meets such criteria.

    This document is a premarket notification for substantial equivalence, which primarily focuses on arguing that a new device is as safe and effective as a legally marketed predicate device. In such submissions, the manufacturer typically references existing performance standards and demonstrates that their device conforms to these rather than presenting a performance study with specific acceptance criteria.

    The summary states:

    • Performance Standards: "The Family of IRIDEX® IQ Laser Systems ... conforms with: Federal Regulations; the performance standards 21 CFR 1040.10 and 1040.11 for medical laser systems: and, International Harmonized Standards." (Page 3)
    • Rationale for Substantial Equivalence: "The Family of IRIDEX IQ Laser Systems shares the same or similar indications for use, device operation, overall technical and functional capabilities, and therefore is substantially equivalent to the predicate devices." (Page 3)
    • Safety and Effectiveness Information: "The review of the indications for use and technical characteristics provided demonstrates that the Family of IRIDEX IQ Laser Systems is substantially equivalent to the predicate devices." (Page 3)

    These statements indicate that the device's conformity is established by adherence to existing regulations and standards, and by demonstrating similarity to previously cleared devices. There is no mention of a specific study conducted by IRIDEX Corporation with defined acceptance criteria to "prove" device performance in the way one might expect for a novel or significantly different device requiring clinical data.

    Therefore, I cannot populate the requested table and answer the specific questions below, as the information is not present in the provided text. The document is a regulatory submission focused on substantial equivalence rather than a detailed report of a performance study with acceptance criteria.