Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K132297

    Validate with FDA (Live)

    Date Cleared
    2013-11-05

    (104 days)

    Product Code
    Regulation Number
    874.4420
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EM Sinus Dilation System is intended for use in sinus procedures when surgical navigation or image-guided surgery may be necessary to locate and move tissue, bone or cartilaginous tissue surrounding the drainage pathways of the frontal, maxillary, and sphenoid sinuses.

    The EM Sinus Dilation system is used in conjunction with the Medtronic computer-assisted surgery system.

    The Medtronic computer-assisted surgery system and its associated applications are intended as an aid for precisely locating anatomical structures in either open or percutaneous procedures. Their use is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as the skull, can be identified relative to a CT- or MR-based model, or digitized landmarks of the anatomy. The system and its associated applications should be used only as an adjunct for surgical guidance. They do not replace the surgeon's knowledge, expertise, or judgment.

    Device Description

    The EM Sinus Dilation System composes of sterile, single-use instruments that combine electromagnetic (EM) "plug and play" tracking capability with the pathway expansion effects of balloon dilatation technology and an inflator. Each of the three types of sinus seekers (frontal, maxillary and sphenoid) has a unique shape with the appropriate angle that allow for entry into the scarred sinus outflow tract. The inflator consists of a plunger, barrel and extension tube.

    Each sinus dilation instrument is intended to be used in conjunction with the Fusion software on a Medtronic computer-assisted surgery system.

    Inside of each sinus seeker is an EM tracker. The emitter on the Fusion System generates a low-energy magnetic field to locate the tracker mounted on the sinus seeker. Then, the software displays the location of the sinus dilation instrument's tip within multiple patient image planes and other anatomic renderings. After confirmation of placement, the sinus seeker's balloon can be inflated with saline solution, using the inflator to expand the outflow track of the targeted sinus.

    AI/ML Overview

    The provided 510(k) summary for the Medtronic EM Sinus Dilation System (K132297) focuses on demonstrating substantial equivalence to predicate devices, primarily through technological characteristics and intended use. It does not include a detailed study proving the device meets specific performance acceptance criteria in the way a diagnostic AI device summary might.

    The submission is for a surgical instrument with electromagnetic tracking, rather than an AI/ML-driven diagnostic tool. Therefore, the typical acceptance criteria and study designs (e.g., sensitivity, specificity, MRMC studies, ground truth establishment) for AI-powered devices are not applicable or detailed in this document.

    However, based on the information provided, I can extract what is stated regarding performance testing and how it relates to ensuring "acceptable navigational accuracy."

    Here's a breakdown of the available information in the requested format, acknowledging the limitations for an AI/ML context:


    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Implied)Reported Device Performance (as stated)
    Functional navigation capability with Medtronic systemsTesting conducted to ensure functionality and compatibility with identified Medtronic products.
    Acceptable navigational accuracyTesting conducted to ensure acceptable navigational accuracy with Medtronic Navigation systems and Fusion software.
    Performance under simulated real-life useTest samples subjected to simulated real-life use conditions during functional testing.

    2. Sample Size Used for the Test Set and the Data Provenance

    • Test Set Sample Size: Not explicitly stated. The document mentions "Test samples" but does not quantify them or describe the nature of these samples (e.g., physical phantoms, cadaveric models, clinical data).
    • Data Provenance: The testing was "Benchtop and simulated environment." There is no mention of country of origin for data, nor whether it was retrospective or prospective, as it appears to be primarily lab-based testing.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts

    • This information is not provided because the device is a surgical instrument with navigation capabilities, not a diagnostic tool requiring expert interpretation of images or clinical data for ground truth establishment. The "ground truth" for navigational accuracy would likely be established by known physical measurements in the simulated environment.

    4. Adjudication Method for the Test Set

    • Not applicable/Not described. Given the nature of the device and testing, expert adjudication in the context of diagnostic performance is not relevant here. Navigational accuracy would typically be objectively measured against known spatial references.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    • No. An MRMC study was not done. This type of study is relevant for evaluating human reader performance, particularly with diagnostic imaging tools where human interpretation is a key component. This device is a surgical instrument, and its performance is evaluated in terms of its physical function and navigational accuracy rather than diagnostic reader performance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done

    • Yes, effectively. The "System Accuracy Method" is described as "Benchtop and simulated environment." This indicates that the functional and navigational accuracy of the device, likely using its electromagnetic tracking algorithm, was evaluated in a controlled setting without a human surgeon performing a full procedure. The document states the system "displays the location of the sinus dilation instrument's tip," implying an objective measurement of this display accuracy.

    7. The Type of Ground Truth Used

    • Implied objective measurements in a simulated environment. While not explicitly stated with details like "pathology" or "outcomes data," the "Benchtop and simulated environment" testing for "System Accuracy" and "navigational accuracy" suggests that the "ground truth" would be precisely known physical positions or measurements within the controlled test setup. For example, a known target position versus the device's reported position.

    8. The Sample Size for the Training Set

    • Not applicable/Not provided. This device is a mechanical surgical instrument with electromagnetic tracking. It does not refer to an AI/ML algorithm that would typically require a "training set" in the conventional sense (e.g., for image recognition or predictive modeling). The "Fusion software" mentioned is likely a deterministic navigation system rather than a machine learning model that undergoes training.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable/Not provided. As there is no explicit mention of a "training set" or an AI/ML model being trained with data in this submission, the method for establishing ground truth for such a set is not discussed.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1