Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K122347

    Validate with FDA (Live)

    Date Cleared
    2013-05-01

    (271 days)

    Product Code
    Regulation Number
    876.5860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Hemodialysis with an ELISIO-H or ELISIO-M hemodialyzer is indicated for patients with acute or chronic renal failure when conservative therapy is judged to be inadequate. It also may be indicated in the treatment of patients intoxicated with poisons or drugs.

    The device is for prescription use only.

    This product is intended for single use only. The performance properties of reused dialyzers have not been established.

    Device Description

    The ELISIO-H and ELISIO-M hemodialyzers are medical devices used as an artificial kidney system for the treatment of patients with renal failure. During treatment, blood is circulated from the patient through the hemodialyzer's blood compartment, while the dialysate solution flows countercurrent through the dialysate compartment. In this process, toxins and/or fluid are transferred across the membrane from the blood to the dialysate compartment.

    The ELISIO-H and ELISIO-M dialyzers are composed of polyethersulfone fiber and are available in various sizes, which are differentiated by membrane surface area.

    AI/ML Overview

    The provided 510(k) summary for the Nipro ELISIO™-H and ELISIO™-M Hemodialyzers (K122347) describes a medical device, not an AI or software-based diagnostic tool. Therefore, many of the requested categories related to AI/algorithm performance, such as "number of experts used," "adjudication method," "MRMC comparative effectiveness study," "standalone performance," and "training set details," are not applicable.

    The acceptance criteria and study are focused on demonstrating substantial equivalence to predicate devices through non-clinical performance testing for a physical medical device.

    1. Table of Acceptance Criteria and Reported Device Performance

    Performance MeasureAcceptance Criteria (Implied)Reported Device Performance
    Analyte Clearance:Comparable to predicate devices (Baxter Xenium XPH and XPM)"Results of these studies establish substantial equivalence"
    - Urea
    - Creatinine
    - Phosphate
    - Vitamin B12 and/or Inulin
    Ultrafiltration CoefficientComparable to predicate devices (Baxter Xenium XPH and XPM)"Results of these studies establish substantial equivalence"
    Pressure DropComparable to predicate devices (Baxter Xenium XPH and XPM)"Results of these studies establish substantial equivalence"
    SafetyMeets established safety standards and is comparable to predicates"Testing performed... indicates that they are safe, effective and perform as well as the predicate devices"
    EffectivenessMeets established effectiveness standards and is comparable to predicates"Testing performed... indicates that they are safe, effective and perform as well as the predicate devices"

    Note on Acceptance Criteria: The document states "Results of these studies establish substantial equivalence." This implies that the acceptance criteria were that the ELISIO™ hemodialyzers performed comparably to, or at least no worse than, the identified predicate devices (K083778 Baxter Xenium XPH Hemodialyzer and K093120 Baxter Xenium XPM Hemodialyzer) for the measured parameters. Specific numerical thresholds are not provided in this summary.

    2. Sample Size Used for the Test Set and the Data Provenance

    The document does not specify exact sample sizes for the non-clinical tests (e.g., how many dialyzers of each type were tested). The data provenance is also not detailed, as these are non-clinical (laboratory/bench) studies on manufactured devices rather than studies on patient data.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts

    Not applicable. This is a physical medical device; its performance is evaluated through objective physical and chemical measurements in a laboratory setting, not by human expert interpretation of data or images.

    4. Adjudication Method for the Test Set

    Not applicable. There is no human interpretation or subjective assessment that would require adjudication.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study Was Done, If so, What Was the Effect Size of How Much Human Readers Improve with AI vs without AI Assistance

    Not applicable. This is not an AI/software-assisted diagnostic device.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) Was Done

    Not applicable. This is not an AI/algorithm-based device.

    7. The Type of Ground Truth Used

    The "ground truth" for the performance characteristics (analyte clearance, ultrafiltration coefficient, pressure drop) would be established through:

    • Physical and Chemical Measurements: Direct, standardized laboratory measurements of the dialyzers' performance using established methods and calibrated equipment.
    • Comparison to Predicate Devices: The performance metrics of the ELISIO™ dialyzers were compared directly to the performance of the legally marketed predicate devices to establish substantial equivalence.

    8. The Sample Size for the Training Set

    Not applicable. This is not an AI/machine learning device that requires a training set.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. This is not an AI/machine learning device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1