510(k) Data Aggregation

    K Number
    K202065

    Validate with FDA (Live)

    Date Cleared
    2020-10-26

    (91 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The DOLOMITE Stand-Alone Cervical Interbody Spacer is indicated for intervertebral body fusion procedures in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine at disc levels (C2-T1). Cervical degenerative disc disease is defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. Patients should have at least six weeks of nonoperative treatment with intervertebral cages. The System is designed for use with autogenous and/or allogeneic bone graft comprised of cancellous and/or corticocancellous bone graft to facilitate fusion.

    The Dolomite Spacer is an interbody fusion device intended to be used with supplemental fixation for one or two levels of the cervical spine.

    The DOLOMITE Spacer and Plate assembly are an integrated interbody fusion device intended for stand-alone use at one or two levels of the cervical spine (C2-T1) and used with titanium alloy screws. Multiple full plate assembly configurations can't be used in conjunction for two contiguous levels of the cervical spine. When used with anchors, the assembly is intended for use at one level of the cervical spine with additional supplemental fixation that has been cleared by the FDA for use in the cervical spine.

    Device Description

    The DOLOMITE Anterior Cervical Stabilization System are implants developed for the stabilization of the cervical column. The spacers are a 2-piece modular design which allows for interchangeable plate and spacer components. The plate and spacer components contain interlocking features in addition to a locking mechanism which allows for intraoperative assembly prior to implantation. The spacer components are available in a range of footprints and heights in PEEK OPTIMA LT120HA or machined Titanium alloy. The plates are offered in multiple fixation types and sizes to suit the individual pathology and anatomical conditions of the patient in machined Titanium alloy. The implants have a hollow center to allow placement of autogenous bone graft. The superior and inferior surfaces are open to promote contact of the bone graft with the vertebral end plates to allow bone growth.

    AI/ML Overview

    The provided text is a 510(k) Premarket Notification from the U.S. Food and Drug Administration (FDA) regarding the Astura Medical, LLC's "DOLOMITE Anterior Cervical Stabilization System." This document is a regulatory notice of substantial equivalence for a medical device and does not contain information about acceptance criteria or a study proving that a device meets acceptance criteria in the context of an AI/ML powered medical device, which is what the prompt is asking for.

    The document explicitly states under "Clinical Test Summary" that "No clinical studies were performed." and under "Non-clinical Test Summary" that "The following analyses were conducted: Dynamic Compression Static Compression Dynamic Torsion Static Torsion. The results of these evaluations indicate that the Dolomite implants are equivalent to predicate devices."

    Therefore, I cannot provide the requested information about acceptance criteria and a study proving a device meets them, specifically in the context of an AI/ML powered medical device, based on the provided text. The text describes a conventional medical device (an intervertebral body fusion device) and its regulatory clearance process, which relies on demonstrating substantial equivalence to predicate devices through mechanical testing, rather than performance against specific acceptance criteria in a clinical study of an AI/ML product.