Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K142886

    Validate with FDA (Live)

    Date Cleared
    2015-03-18

    (167 days)

    Product Code
    Regulation Number
    872.3750
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This device is a one step no-mix adhesive for direct bonding of orthodontic bracket to tooth structure

    Device Description

    The DMRC Self-Cure Bracket Adhesive One Step and Primer is a resin based adhesive designed for direct bonding of orthodontic brackets with no-mix step.

    AI/ML Overview

    The document describes the DMRC Self-Cure Bracket Adhesive One Step and Primer and its substantial equivalence to a predicate device based on non-clinical testing.

    Here's the information requested:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document does not explicitly state "acceptance criteria" in a quantitative sense with pass/fail thresholds. Instead, it presents the results of bench testing for the DMRC Self-Cure Bracket Adhesive One Step and Primer alongside the predicate device's performance to demonstrate "equivalence." The implied acceptance criterion is that the new device's performance is comparable to or better than the predicate device.

    Test MethodDMRC Self-Cure Bracket Adhesive and Primer (Reported Performance)System 1+ and Activator (Ormco) (Predicate Device Performance)
    Vicker's Hardness37 (5)29 (3)
    Shear Bond Strength on enamel (MPa)6.7 (1)5.2 (0.7)
    Self-Cure Set Time (min)2:302:00

    2. Sample Size Used for the Test Set and Data Provenance:

    The document does not specify the exact sample sizes (e.g., number of specimens tested) for the Vicker's Hardness, Shear Bond Strength, or Self-Cure Set Time tests. It also does not explicitly mention the country of origin of the data or whether the data was retrospective or prospective. These were non-clinical bench tests, not human studies.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications:

    Not applicable. The "test set" here refers to non-clinical bench tests on materials, not a set of clinical cases requiring expert interpretation.

    4. Adjudication Method for the Test Set:

    Not applicable for non-clinical bench tests. The results are quantitative measurements.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:

    No, an MRMC comparative effectiveness study was not done. This product is a dental adhesive, and the evaluation was based on non-clinical material properties.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done:

    Not applicable. This is not an AI/algorithm-based device.

    7. The Type of Ground Truth Used:

    For the non-clinical tests, the "ground truth" is the quantitative measurement obtained through standardized laboratory testing procedures for properties like Vicker's Hardness, Shear Bond Strength, and Self-Cure Set Time.

    8. The Sample Size for the Training Set:

    Not applicable. This is not an AI/machine learning device that requires a training set.

    9. How the Ground Truth for the Training Set Was Established:

    Not applicable. This is not an AI/machine learning device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1